ENTRY 20650 20230201 2065000000001 SUBENT 20650001 20230201 20231011 2065000100001 BIB 16 24 2065000100002 TITLE The infinite dilute resonance integral of thorium 2065000100003 AUTHOR (M.Brose) 2065000100004 REFERENCE (J,NSE,19,244,1964) 2065000100005 (P,EANDC(E)-23,5,1962) same experiment. 2065000100006 INSTITUTE (2GERKFK) 2065000100007 FACILITY (REAC,2GERMUN) FRM (Munich) reactor 2065000100008 INC-SOURCE (REAC) Position in the pool of the Munich reactor. 2065000100009 SAMPLE Thin circular thorium and gold foils. 2065000100010 METHOD (ACTIV) 2065000100011 DETECTOR Gamma spectrometer. 2065000100012 ANALYSIS Cadmium ratio measurements. 2065000100013 MONITOR (79-AU-197(N,G)79-AU-198,,RI) 2065000100014 Res.integral with 1/V-part =1461.8b, 2065000100015 effective cross section = 99.3 b. 2065000100016 Effective cross section of thorium = 7.45+-0.15 b. 2065000100017 COMMENT The used value for the resonance integral of the 2065000100018 gold standard is in disagreement with the value 2065000100019 of 1551 b which is accepted from most authors. 2065000100020 CORRECTION For the self-shielding in gold foils. 2065000100021 ERR-ANALYS (DATA-ERR) No information is given. 2065000100022 STATUS (TABLE) Text on p.245 of Nucl.Sci.Eng.,19(1964)244. 2065000100023 HISTORY (19761013C) 2065000100024 (20230201U) SD:Updated to new date formats,lower case. 2065000100025 Corrections in all Subents. 2065000100026 ENDBIB 24 0 2065000100027 NOCOMMON 0 0 2065000100028 ENDSUBENT 27 0 2065000199999 SUBENT 20650002 20230201 20231011 2065000200001 BIB 1 1 2065000200002 REACTION (90-TH-232(N,G)90-TH-233,,RI) 2065000200003 ENDBIB 1 0 2065000200004 NOCOMMON 0 0 2065000200005 DATA 3 1 2065000200006 EN-MIN DATA DATA-ERR 2065000200007 EV B B 2065000200008 0.5 82.7 1.8 2065000200009 ENDDATA 3 0 2065000200010 ENDSUBENT 9 0 2065000299999 ENDENTRY 2 0 2065099999999