ENTRY 21994 20150804 22432199400000001 SUBENT 21994001 20150804 22432199400100001 BIB 10 29 2199400100002 INSTITUTE (2GERJUL) 2199400100003 REFERENCE (J,NP/A,438,(2),384,198505) 2199400100004 AUTHOR (S.M.Qaim) 2199400100005 TITLE Isomeric cross-section ratios in (n,t) reactions on 2199400100006 some medium-and-heavy mass nuclei at 14.6 MeV. 2199400100007 FACILITY (NGEN,2GERJUL) Dynagen neutron generator. 2199400100008 INC-SOURCE (D-T) Average energy of the neutrons was 14.6+-0.4 MeV 2199400100009 METHOD (ACTIV) For all isotopes 2199400100010 STATUS (TABLE) .Data taken from NP/A,438,(2),384 2199400100011 ERR-ANALYS (ERR-T) Combining the statistical and systematic errors2199400100012 in quadrature. Major systematic errors due to: 2199400100013 (ERR-1,5.,20.) determination of neutron flux via 2199400100014 monitor reactions and 2199400100015 determination of desintegration rates of the products 2199400100016 involving several uncertainties, for example, 2199400100017 (ERR-2,3.,5.) uncertainty in efficiencies of the 2199400100018 detectors; 2199400100019 (ERR-3,2.,4.) uncertainty in absorption of gamma-rays; 2199400100020 (ERR-4,1.,2.) uncertainty in decay data; 2199400100021 (ERR-5) uncertainty in chemical yield; etc. 2199400100022 (MONIT-ERR) normalization error 2199400100023 HISTORY (19860127C) IF. 2199400100024 (19860618U)HH 2199400100025 (20150804A) SD:Updated to new date formats,lower case. 2199400100026 Corrections according last EXFOR rules and Dict. 2199400100027 BIB update. SAMPLE, DETECTOR moved to Subents 2-8. 2199400100028 FACILITY added. 2199400100029 REACTION (1) deleted from Subents 2-8 according to 2199400100030 Dr.Otsuka remark (see explanation in Subents). 2199400100031 ENDBIB 29 0 2199400100032 COMMON 3 3 2199400100033 EN EN-ERR ERR-5 2199400100034 MEV MEV PER-CENT 2199400100035 14.6 0.4 2. 2199400100036 ENDCOMMON 3 0 2199400100037 ENDSUBENT 36 0 2199400199999 SUBENT 21994002 20150804 22432199400200001 BIB 7 12 2199400200002 REACTION (35-BR-79(N,T)34-SE-77-M,,SIG) 2199400200003 DECAY-DATA (34-SE-77-M,17.5SEC,DG,162.,0.525) 2199400200004 MONITOR (35-BR-79(N,A)33-AS-76,,SIG) 2199400200005 DECAY-MON (33-AS-76,26.40HR,DG) 2199400200006 SAMPLE 2gr of K+Br; or 0.5 gr Na-79 + Br (Br-79 - 99.75%, 2199400200007 Br-81 - 0.25%). The target material was filled in 2199400200008 a PVC capsule (0.7 cm diameter, 3.8 cm long, 0.25 cm 2199400200009 thick) and introduced in a fast pneumatic-tube system.2199400200010 DETECTOR (GELI) 35 cm3 Ge(Li) detector coupled to a 24 K memory 2199400200011 ND 4420 system was used. 2199400200012 HISTORY (20150804A) SD: REACTION (1) deleted (not for EXFOR- 2199400200013 denominator is from systematics). 2199400200014 ENDBIB 12 0 2199400200015 NOCOMMON 0 0 2199400200016 DATA 4 1 2199400200017 MONIT MONIT-ERR DATA ERR-T 2199400200018 MB MB MICRO-B MICRO-B 2199400200019 16. 2. 120. 50. 2199400200020 ENDDATA 3 0 2199400200021 ENDSUBENT 20 0 2199400299999 SUBENT 21994003 20150804 22432199400300001 BIB 7 12 2199400300002 REACTION (38-SR-88(N,T)37-RB-86-M,,SIG) 2199400300003 DECAY-DATA (37-RB-86-M,61.SEC,DG,556.,0.982) 2199400300004 MONITOR (38-SR-88(N,P)37-RB-88,,SIG) 2199400300005 DECAY-MON (37-RB-88,17.80MIN,DG) 2199400300006 SAMPLE (38-SR-88,ENR=0.9984) 2.5 gr of 88Sr(NO3)2. 2199400300007 Sample was packed in polyethylene bag, sandwiched 2199400300008 between 2 aluminium foils and irradiated in 2199400300009 the conventional way. 2199400300010 DETECTOR (GELI) 35 cm3 Ge(Li) detector coupled to a 24 K memory 2199400300011 ND 4420 system was used. 2199400300012 HISTORY (20150804A) SD: REACTION (1) deleted (not for EXFOR- 2199400300013 the source of the denominator unclear). 2199400300014 ENDBIB 12 0 2199400300015 NOCOMMON 0 0 2199400300016 DATA 4 1 2199400300017 MONIT MONIT-ERR DATA ERR-T 2199400300018 MB MB MICRO-B MICRO-B 2199400300019 13.5 1.5 12. 5. 2199400300020 ENDDATA 3 0 2199400300021 ENDSUBENT 20 0 2199400399999 SUBENT 21994004 20150804 22432199400400001 BIB 8 13 2199400400002 REACTION (49-IN-113(N,X)48-CD-111-M,,SIG) 2199400400003 DECAY-DATA (48-CD-111-M,49.MIN,DG,245.,0.942) 2199400400004 MONITOR (13-AL-27(N,A)11-NA-24,,SIG) 2199400400005 DECAY-MON (11-NA-24,15.0HR,DG) 2199400400006 SAMPLE 10gr of In. Sample was packed in polyethylene bag, 2199400400007 sandwiched between 2 aluminium foils and irradiated 2199400400008 in the conventional way. 2199400400009 METHOD (CHSEP) 2199400400010 DETECTOR (GELI) 35 cm3 Ge(Li) detector coupled to a 24 K memory 2199400400011 ND 4420 system was used. 2199400400012 HISTORY (20150804A) SD: REACTION (1) deleted (not for EXFOR- 2199400400013 denominator is from systematics). SF3=T -> X in 2199400400014 REACTION code. In-113m -> Cd-111m in DECAY-DATA. 2199400400015 ENDBIB 13 0 2199400400016 NOCOMMON 0 0 2199400400017 DATA 4 1 2199400400018 MONIT MONIT-ERR DATA ERR-T 2199400400019 MB MB MICRO-B MICRO-B 2199400400020 115. 3. 43. 20. 2199400400021 ENDDATA 3 0 2199400400022 ENDSUBENT 21 0 2199400499999 SUBENT 21994005 20150804 22432199400500001 BIB 8 13 2199400500002 REACTION (53-I-127(N,X)52-TE-125-M,,SIG) 2199400500003 DECAY-DATA (52-TE-125-M,58.D,DG,35.5,0.067) 2199400500004 MONITOR (53-I-127(N,P)52-TE-127-M,,SIG) 2199400500005 DECAY-MON (52-TE-127-M,109.D,DG,57.5,0.005) 2199400500006 METHOD (CHSEP) 2199400500007 SAMPLE 12 gr of KI. Sample was packed in polyethylene bag, 2199400500008 sandwiched between 2 aluminium foils and irradiated 2199400500009 in the conventional way. 2199400500010 DETECTOR (GE-IN) intrinsic Ge detector with an active area of 2199400500011 2 cm2 (having a thin beryllium window). 2199400500012 HISTORY (20150804A) SD: REACTION (1) deleted (not for EXFOR- 2199400500013 denominator is from systematics). SF3=T -> X in 2199400500014 REACTION code. 2199400500015 ENDBIB 13 0 2199400500016 NOCOMMON 0 0 2199400500017 DATA 4 1 2199400500018 MONIT MONIT-ERR DATA ERR-T 2199400500019 MB MB MICRO-B MICRO-B 2199400500020 8. 1.6 35. 10. 2199400500021 ENDDATA 3 0 2199400500022 ENDSUBENT 21 0 2199400599999 SUBENT 21994006 20150804 22432199400600001 BIB 7 12 2199400600002 REACTION (59-PR-141(N,X)58-CE-139-M,,SIG) 2199400600003 DECAY-DATA (58-CE-139-M,56.5SEC,DG,754.,0.925) 2199400600004 MONITOR (59-PR-141(N,P)58-CE-141,,SIG) 2199400600005 DECAY-MON (58-CE-141,32.5D,DG) 2199400600006 SAMPLE 2 gr of Pr(6)O(11). Sample was packed in polyethylene 2199400600007 bag, sandwiched between 2 aluminium foils and 2199400600008 irradiated in the conventional way. 2199400600009 DETECTOR (GELI) 35 cm3 Ge(Li) detector coupled to a 24 K memory 2199400600010 ND 4420 system was used. 2199400600011 HISTORY (20150804A) SD: REACTION (1) deleted (not for EXFOR- 2199400600012 the source of the denominator unclear). SF3=T -> X in 2199400600013 REACTION code. 2199400600014 ENDBIB 12 0 2199400600015 NOCOMMON 0 0 2199400600016 DATA 4 1 2199400600017 MONIT MONIT-ERR DATA ERR-T 2199400600018 MB MB MICRO-B MICRO-B 2199400600019 9. 1.5 26. 10. 2199400600020 ENDDATA 3 0 2199400600021 ENDSUBENT 20 0 2199400699999 SUBENT 21994007 20150804 22432199400700001 BIB 7 12 2199400700002 REACTION (69-TM-169(N,X)68-ER-167-M,,SIG) 2199400700003 DECAY-DATA (68-ER-167-M,2.3SEC,DG,208.,0.417) 2199400700004 MONITOR (69-TM-169(N,2N)69-TM-168,,SIG) 2199400700005 DECAY-MON (69-TM-168,93.D,DG) 2199400700006 SAMPLE 2 gr of Tm(2)O(3). The target material was filled in a 2199400700007 PVC capsule (0.7 cm diameter, 3.8 cm long, 0.25 cm 2199400700008 thick) and introduced in a fast pneumatic-tube system. 2199400700009 DETECTOR (GELI) 35 cm3 Ge(Li) detector coupled to a 24 K memory 2199400700010 ND 4420 system was used. 2199400700011 HISTORY (20150804A) SD: REACTION (1) deleted (not for EXFOR- 2199400700012 denominator is from systematics). SF3=T -> X in 2199400700013 REACTION code. 2199400700014 ENDBIB 12 0 2199400700015 NOCOMMON 0 0 2199400700016 DATA 4 1 2199400700017 MONIT MONIT-ERR DATA ERR-T 2199400700018 MB MB MICRO-B MICRO-B 2199400700019 1971. 152. 29. 16. 2199400700020 ENDDATA 3 0 2199400700021 ENDSUBENT 20 0 2199400799999 SUBENT 21994008 20150804 22432199400800001 BIB 7 13 2199400800002 REACTION (73-TA-181(N,X)72-HF-179-M1,,SIG) 2199400800003 DECAY-DATA (72-HF-179-M1,18.60SEC,DG,214.,0.952) 2199400800004 MONITOR (73-TA-181(N,2N)73-TA-180-G,,SIG) 2199400800005 DECAY-MON (73-TA-180-G,8.1HR,DG) 2199400800006 SAMPLE 2 gr of Ta. The target material was filled in a 2199400800007 PVC capsule (0.7 cm diameter, 3.8 cm long, 0.25 cm 2199400800008 thick) and introduced in a fast pneumatic-tube system. 2199400800009 DETECTOR (GELI) 35 cm3 Ge(Li) detector coupled to a 24 K memory 2199400800010 ND 4420 system was used. 2199400800011 HISTORY (20150804A) SD: REACTION (1) deleted (not for EXFOR- 2199400800012 denominator is from systematics). SF3=T -> X in 2199400800013 REACTION code. Hf-179m -> Hf-179m1 in REACTION code and2199400800014 DECAY-DATA. Ta-180 -> Ta-180g in MONITOR and DECAY-MON 2199400800015 ENDBIB 13 0 2199400800016 NOCOMMON 0 0 2199400800017 DATA 4 1 2199400800018 MONIT MONIT-ERR DATA ERR-T 2199400800019 MB MB MICRO-B MICRO-B 2199400800020 1150. 100. 10. 5. 2199400800021 ENDDATA 3 0 2199400800022 ENDSUBENT 21 0 2199400899999 ENDENTRY 8 0 2199499999999