ENTRY 22156 20150819 22432215600000001 SUBENT 22156001 20150819 22432215600100001 BIB 11 33 2215600100002 REFERENCE ((R,JAERI-M-89-083,1989)=(R,NEANDC(J)-137,1989)= 2215600100003 (R,INDC(JPN)-124,1989)) Main ref, Japanese text 2215600100004 (R,JAERI-M-89-026,293,1989) Preliminary subset of 2215600100005 results in English 2215600100006 TITLE Measurement of activation cross sections. 2215600100007 AUTHOR (T.Katoh,K.Kawade,H.Yamamoto) 2215600100008 INSTITUTE (2JPNNAG) Kato, Kawada, Yamamoto 2215600100009 (2JPNOSA) Experimental site 2215600100010 FACILITY (CCW,2JPNOSA) The intense 14 MeV neutron source 2215600100011 Oktavian at Osaka University. 2215600100012 INC-SOURCE (D-T) A sample transport system of six pneumatic 2215600100013 tubes at angles of 0 - 155 deg to the deuteron beam 2215600100014 provided irradiation positions experiencing mono- 2215600100015 chromatic neutrons of 13.40 - 14.87 MeV, the effective2215600100016 reaction neutron energy at each position being deter- 2215600100017 mined by the Zr/Nb method. 2215600100018 METHOD (ACTIV) 2215600100019 CORRECTION .Neutron flux variation over time, sample thickness, 2215600100020 self-absorption. 2215600100021 ERR-ANALYS (ERR-1) Experimental error, including statistical and 2215600100022 systematic 2215600100023 (ERR-2) Nuclear data error, including those of monitor 2215600100024 cross section and gamma intensities. 2215600100025 (ERR-T) Total error, quadrature sum of ERR-1 and -2. 2215600100026 STATUS (TABLE) .Data obtained from authors on tape 2215600100027 by T.Nakagawa. 2215600100028 (PRELM) Declared by the authors 2215600100029 HISTORY (19901218C) S.W. 2215600100030 (19910403A) S.W. ERR-1 and -T data corrected, Sub 014 2215600100031 (20060117U) Corrected SM/MM. Date changed, some data 2215600100032 superseded 2215600100033 (20060123A) SUBENTs 22156019, -020 corrected - SM 2215600100034 (20150819U) SD: Status 'superseded" added to Subs 7,15.2215600100035 ENDBIB 33 0 2215600100036 NOCOMMON 0 0 2215600100037 ENDSUBENT 36 0 2215600199999 SUBENT 22156002 20060123 21752215600200001 BIB 7 15 2215600200002 REACTION (7-N-14(N,2N)7-N-13,,SIG) 2215600200003 DECAY-DATA (7-N-13,9.96MIN,AR,511.,1.9962) 2215600200004 SAMPLE .Weight 70 mg, 99.99% purity 2215600200005 .Two Al monitor foils, 1. X 1. X 0.02 cm, 99.2% purity.2215600200006 DETECTOR .The detected gamma was from B+ annihilation occurring 2215600200007 in the 10 mm thick acrylic plates either side of the 2215600200008 irradiated sample. 2215600200009 (HPGE ) Vertical hpge, 12% efficiency, 1.75 KeV 2215600200010 resolution 2215600200011 (HPGE ) For Al monitor foil, horizontal hpge, 2215600200012 16% efficiency, 1.75 KeV resolution. 2215600200013 MONITOR (13-AL-27(N,P)12-MG-27,,SIG) Based on standard 2215600200014 Al-27(N,a) reaction in ENDF/B-V. Errors within 0.5%. 2215600200015 DECAY-MON (12-MG-27,9.46MIN,DG,843.8,.73) 2215600200016 STATUS (SPSDD,22662002) 2215600200017 ENDBIB 15 0 2215600200018 NOCOMMON 0 0 2215600200019 DATA 7 6 2215600200020 EN EN-ERR DATA ERR-1 ERR-2 ERR-T 2215600200021 MONIT 2215600200022 MEV MEV MB PER-CENT PER-CENT PER-CENT 2215600200023 MB 2215600200024 14.87 0.05 7.2 2.6 3. 4.2215600200025 66.82 2215600200026 14.64 0.05 7.28 2.8 3. 4.12215600200027 69.4 2215600200028 14.35 0.05 7.07 2.9 3. 4.22215600200029 72.66 2215600200030 14.01 0.05 5.84 3. 3. 4.22215600200031 76.36 2215600200032 13.7 0.05 4.63 3.3 3. 4.52215600200033 79.95 2215600200034 13.4 0.05 3.59 2.7 3. 4.2215600200035 83.32 2215600200036 ENDDATA 16 0 2215600200037 ENDSUBENT 36 0 2215600299999 SUBENT 22156003 20060123 21752215600300001 BIB 7 15 2215600300002 REACTION (15-P-31(N,2N)15-P-30,,SIG) 2215600300003 DECAY-DATA (15-P-30,2.50MIN,AR,511.,2.0) 2215600300004 SAMPLE .Weight 60 mg, 99.999% purity 2215600300005 .Two Al monitor foils, 1. X 1. X 0.02 cm, 99.2% purity.2215600300006 DETECTOR .The detected gamma was from B+ annihilation occurring 2215600300007 in the 10 mm thick acrylic plates either side of the 2215600300008 irradiated sample. 2215600300009 (HPGE ) Vertical hpge, 12% efficiency, 1.75 KeV 2215600300010 resolution 2215600300011 (HPGE ) For Al monitor foil, horizontal hpge, 2215600300012 16% efficiency, 1.75 KeV resolution. 2215600300013 MONITOR (13-AL-27(N,P)12-MG-27,,SIG) Based on standard 2215600300014 Al-27(N,a) reaction in ENDF/B-V. Errors within 0.5%. 2215600300015 DECAY-MON (12-MG-27,9.46MIN,DG,843.8,.73) 2215600300016 STATUS (SPSDD,22662003) 2215600300017 ENDBIB 15 0 2215600300018 NOCOMMON 0 0 2215600300019 DATA 7 6 2215600300020 EN EN-ERR DATA ERR-1 ERR-2 ERR-T 2215600300021 MONIT 2215600300022 MEV MEV MB PER-CENT PER-CENT PER-CENT 2215600300023 MB 2215600300024 14.87 0.05 15. 5. 3. 5.82215600300025 66.82 2215600300026 14.64 0.05 13.2 4.5 3. 5.42215600300027 69.4 2215600300028 14.35 0.05 11.1 4.6 3. 5.52215600300029 72.66 2215600300030 14.01 0.05 6. 5.7 3. 6.42215600300031 76.36 2215600300032 13.7 0.05 3. 8.8 3. 9.32215600300033 79.95 2215600300034 13.4 0.05 1.1 13. 3. 20.2215600300035 83.32 2215600300036 ENDDATA 16 0 2215600300037 ENDSUBENT 36 0 2215600399999 SUBENT 22156004 20060123 21752215600400001 BIB 7 12 2215600400002 REACTION (15-P-31(N,A)13-AL-28,,SIG) 2215600400003 DECAY-DATA (13-AL-28,2.241MIN,DG,1778.7,1.0) 2215600400004 SAMPLE .Weight 60 mg, 99.999% purity 2215600400005 .Two Al monitor foils, 1. X 1. X 0.02 cm, 99.2% purity.2215600400006 DETECTOR (HPGE ) Vertical hpge, 12% efficiency, 1.75 KeV 2215600400007 resolution 2215600400008 (HPGE ) For Al monitor foil, horizontal hpge, 2215600400009 16% efficiency, 1.75 KeV resolution. 2215600400010 MONITOR (13-AL-27(N,P)12-MG-27,,SIG) Based on standard 2215600400011 Al-27(N,a) reaction in ENDF/B-V. Errors within 0.5%. 2215600400012 DECAY-MON (12-MG-27,9.46MIN,DG,843.8,.73) 2215600400013 STATUS (SPSDD,22434004) 2215600400014 ENDBIB 12 0 2215600400015 NOCOMMON 0 0 2215600400016 DATA 7 6 2215600400017 EN EN-ERR DATA ERR-1 ERR-2 ERR-T 2215600400018 MONIT 2215600400019 MEV MEV MB PER-CENT PER-CENT PER-CENT 2215600400020 MB 2215600400021 14.87 0.05 116. 3.6 3. 4.72215600400022 66.82 2215600400023 14.64 0.05 116. 3.5 3. 4.62215600400024 69.4 2215600400025 14.35 0.05 126. 3.4 3. 4.52215600400026 72.66 2215600400027 14.01 0.05 134. 3.4 3. 4.52215600400028 76.36 2215600400029 13.7 0.05 130. 3.5 3. 4.62215600400030 79.95 2215600400031 13.4 0.05 135. 2.6 3. 4.2215600400032 83.32 2215600400033 ENDDATA 16 0 2215600400034 ENDSUBENT 33 0 2215600499999 SUBENT 22156005 20060123 21752215600500001 BIB 6 11 2215600500002 REACTION (23-V-51(N,P)22-TI-51,,SIG) 2215600500003 DECAY-DATA (22-TI-51,5.76MIN,DG,319.7,.93) 2215600500004 SAMPLE .Weight 80 mg, 99.99% purity 2215600500005 .Two Al monitor foils, 1. X 1. X 0.02 cm, 99.2% purity.2215600500006 DETECTOR (HPGE ) Vertical hpge, 12% efficiency, 1.75 KeV 2215600500007 resolution 2215600500008 (HPGE ) For Al monitor foil, horizontal hpge, 2215600500009 16% efficiency, 1.75 KeV resolution. 2215600500010 MONITOR (13-AL-27(N,P)12-MG-27,,SIG) Based on standard 2215600500011 Al-27(N,a) reaction in ENDF/B-V. Errors within 0.5%. 2215600500012 DECAY-MON (12-MG-27,9.46MIN,DG,843.8,.73) 2215600500013 ENDBIB 11 0 2215600500014 NOCOMMON 0 0 2215600500015 DATA 7 6 2215600500016 EN EN-ERR DATA ERR-1 ERR-2 ERR-T 2215600500017 MONIT 2215600500018 MEV MEV MB PER-CENT PER-CENT PER-CENT 2215600500019 MB 2215600500020 14.87 0.05 30.8 5.3 3. 6.12215600500021 66.82 2215600500022 14.64 0.05 33. 4.9 3. 5.72215600500023 69.4 2215600500024 14.35 0.05 33.8 4.9 3. 5.72215600500025 72.66 2215600500026 14.01 0.05 33.8 4.6 3. 5.52215600500027 76.36 2215600500028 13.7 0.05 32.3 5. 3. 5.82215600500029 79.95 2215600500030 13.4 0.05 34.4 4.1 3. 5.12215600500031 83.32 2215600500032 ENDDATA 16 0 2215600500033 ENDSUBENT 32 0 2215600599999 SUBENT 22156006 20060123 21752215600600001 BIB 7 13 2215600600002 REACTION (26-FE-54(N,2N)26-FE-53-G,,SIG) 2215600600003 DECAY-DATA (26-FE-53-G,8.51MIN,DG,377.9,.42) 2215600600004 SAMPLE .Weight 70 mg, 97.20% enriched, impurities: 56 (2.75%),2215600600005 57 (0.05%) and 58 (<0.01%) 2215600600006 .Two Al monitor foils, 1. X 1. X 0.02 cm, 99.2% purity.2215600600007 DETECTOR (HPGE ) Vertical hpge, 12% efficiency, 1.75 KeV 2215600600008 resolution 2215600600009 (HPGE ) For Al monitor foil, horizontal hpge, 2215600600010 16% efficiency, 1.75 KeV resolution. 2215600600011 MONITOR (13-AL-27(N,P)12-MG-27,,SIG) Based on standard 2215600600012 Al-27(N,a) reaction in ENDF/B-V. Errors within 0.5%. 2215600600013 DECAY-MON (12-MG-27,9.46MIN,DG,843.8,.73) 2215600600014 STATUS (SPSDD,22662004) 2215600600015 ENDBIB 13 0 2215600600016 NOCOMMON 0 0 2215600600017 DATA 7 5 2215600600018 EN EN-ERR DATA ERR-1 ERR-2 ERR-T 2215600600019 MONIT 2215600600020 MEV MEV MB PER-CENT PER-CENT PER-CENT 2215600600021 MB 2215600600022 14.87 0.05 10.9 5.4 19. 20.2215600600023 66.82 2215600600024 14.64 0.05 9. 5.5 19. 20.2215600600025 69.4 2215600600026 14.35 0.05 5.3 6.4 19. 20.2215600600027 72.66 2215600600028 14.01 0.05 2.1 9.8 19. 21.2215600600029 76.36 2215600600030 13.7 0.05 0.22 80. 19. 90.2215600600031 79.95 2215600600032 ENDDATA 14 0 2215600600033 ENDSUBENT 32 0 2215600699999 SUBENT 22156007 20150819 22432215600700001 BIB 8 16 2215600700002 REACTION (28-NI-60(N,P)27-CO-60-M,,SIG) 2215600700003 DECAY-DATA (27-CO-60-M,10.47MIN,DG,58.6,.02) 2215600700004 SAMPLE (28-NI-60,ENR=0.9965) .Weight 70 mg, 99.65% enriched, 2215600700005 impurities: Ni-58 (0.29%), Ni-61 (0.03%), 2215600700006 Ni-62 (0.03%) and Ni-64 (<0.08%) 2215600700007 .Two Al monitor foils, 1. x 1. x 0.02 cm, 99.2% purity.2215600700008 DETECTOR (HPGE ) Vertical HPGe, 12% efficiency, 1.75 keV 2215600700009 resolution 2215600700010 (HPGE ) For Al monitor foil, horizontal HPGe, 2215600700011 16% efficiency, 1.75 keV resolution. 2215600700012 MONITOR (13-AL-27(N,P)12-MG-27,,SIG) Based on standard 2215600700013 Al-27(n,alpha) reaction in ENDF/B-V.Errors within 0.5%2215600700014 DECAY-MON (12-MG-27,9.46MIN,DG,843.8,.73) 2215600700015 STATUS (SPSDD,22433010) 2215600700016 HISTORY (20150819U) SD: Status 'superseded' corrected 2215600700017 (22433011-> 22433010). Small additional corrections. 2215600700018 ENDBIB 16 0 2215600700019 NOCOMMON 0 0 2215600700020 DATA 7 3 2215600700021 EN EN-ERR DATA ERR-1 ERR-2 ERR-T 2215600700022 MONIT 2215600700023 MEV MEV MB PER-CENT PER-CENT PER-CENT 2215600700024 MB 2215600700025 14.87 0.05 74. 8. 5.9 10.2215600700026 66.82 2215600700027 14.01 0.05 95. 8. 5.9 10.2215600700028 76.36 2215600700029 13.4 0.05 100. 8. 5.9 10.2215600700030 83.32 2215600700031 ENDDATA 10 0 2215600700032 ENDSUBENT 31 0 2215600799999 SUBENT 22156008 20060123 21752215600800001 BIB 7 12 2215600800002 REACTION (28-NI-62(N,P)27-CO-62-M,,SIG) 2215600800003 DECAY-DATA (27-CO-62-M,13.91MIN,DG,1163.5,.681) 2215600800004 SAMPLE .Weight 40 mg, 97.01% enriched 2215600800005 .Two Al monitor foils, 1. X 1. X 0.02 cm, 99.2% purity.2215600800006 DETECTOR (HPGE ) Vertical hpge, 12% efficiency, 1.75 KeV 2215600800007 resolution 2215600800008 (HPGE ) For Al monitor foil, horizontal hpge, 2215600800009 16% efficiency, 1.75 KeV resolution. 2215600800010 MONITOR (13-AL-27(N,P)12-MG-27,,SIG) Based on standard 2215600800011 Al-27(N,a) reaction in ENDF/B-V. Errors within 0.5%. 2215600800012 DECAY-MON (12-MG-27,9.46MIN,DG,843.8,.73) 2215600800013 STATUS (SPSDD,22433011) 2215600800014 ENDBIB 12 0 2215600800015 NOCOMMON 0 0 2215600800016 DATA 7 6 2215600800017 EN EN-ERR DATA ERR-1 ERR-2 ERR-T 2215600800018 MONIT 2215600800019 MEV MEV MB PER-CENT PER-CENT PER-CENT 2215600800020 MB 2215600800021 14.87 0.05 19.5 6.9 3.6 7.82215600800022 66.82 2215600800023 14.64 0.05 18.3 7.1 3.6 8.2215600800024 69.4 2215600800025 14.35 0.05 16.7 6.5 3.6 7.42215600800026 72.66 2215600800027 14.01 0.05 17.5 5.2 3.6 6.42215600800028 76.36 2215600800029 13.7 0.05 11.9 11. 3.6 12.2215600800030 79.95 2215600800031 13.4 0.05 13.1 5.3 3.6 6.42215600800032 83.32 2215600800033 ENDDATA 16 0 2215600800034 ENDSUBENT 33 0 2215600899999 SUBENT 22156009 20060123 21752215600900001 BIB 7 12 2215600900002 REACTION (28-NI-62(N,P)27-CO-62-G,,SIG) 2215600900003 DECAY-DATA (27-CO-62-G,1.50MIN,DG,1129.1,.113) 2215600900004 SAMPLE .Weight 40 mg, 97.01% enriched 2215600900005 .Two Al monitor foils, 1. X 1. X 0.02 cm, 99.2% purity.2215600900006 DETECTOR (HPGE ) Vertical hpge, 12% efficiency, 1.75 KeV 2215600900007 resolution 2215600900008 (HPGE ) For Al monitor foil, horizontal hpge, 2215600900009 16% efficiency, 1.75 KeV resolution. 2215600900010 MONITOR (13-AL-27(N,P)12-MG-27,,SIG) Based on standard 2215600900011 Al-27(N,a) reaction in ENDF/B-V. Errors within 0.5%. 2215600900012 DECAY-MON (12-MG-27,9.46MIN,DG,843.8,.73) 2215600900013 STATUS (SPSDD,22433012) 2215600900014 ENDBIB 12 0 2215600900015 NOCOMMON 0 0 2215600900016 DATA 7 6 2215600900017 EN EN-ERR DATA ERR-1 ERR-2 ERR-T 2215600900018 MONIT 2215600900019 MEV MEV MB PER-CENT PER-CENT PER-CENT 2215600900020 MB 2215600900021 14.87 0.05 26. 17. 6.9 19.2215600900022 66.82 2215600900023 14.64 0.05 33. 23. 6.9 24.2215600900024 69.4 2215600900025 14.35 0.05 25. 19. 6.9 20.2215600900026 72.66 2215600900027 14.01 0.05 21. 16. 6.9 17.2215600900028 76.36 2215600900029 13.7 0.05 17. 40. 6.9 41.2215600900030 79.95 2215600900031 13.4 0.05 16. 15. 6.9 17.2215600900032 83.32 2215600900033 ENDDATA 16 0 2215600900034 ENDSUBENT 33 0 2215600999999 SUBENT 22156010 20060123 21752215601000001 BIB 7 12 2215601000002 REACTION (29-CU-63(N,A)27-CO-60-M,,SIG) 2215601000003 DECAY-DATA (27-CO-60-M,10.47MIN,DG,58.6,.02) 2215601000004 SAMPLE .Weight 90 mg natural Cu, 99.9% purity 2215601000005 .Two Al monitor foils, 1. X 1. X 0.02 cm, 99.2% purity.2215601000006 DETECTOR (HPGE ) Vertical hpge, 12% efficiency, 1.75 KeV 2215601000007 resolution 2215601000008 (HPGE ) For Al monitor foil, horizontal hpge, 2215601000009 16% efficiency, 1.75 KeV resolution. 2215601000010 MONITOR (13-AL-27(N,P)12-MG-27,,SIG) Based on standard 2215601000011 Al-27(N,a) reaction in ENDF/B-V. Errors within 0.5%. 2215601000012 DECAY-MON (12-MG-27,9.46MIN,DG,843.8,.73) 2215601000013 STATUS (SPSDD,22434006) 2215601000014 ENDBIB 12 0 2215601000015 NOCOMMON 0 0 2215601000016 DATA 7 6 2215601000017 EN EN-ERR DATA ERR-1 ERR-2 ERR-T 2215601000018 MONIT 2215601000019 MEV MEV MB PER-CENT PER-CENT PER-CENT 2215601000020 MB 2215601000021 14.87 0.05 8. 31. 5.9 32.2215601000022 66.82 2215601000023 14.64 0.05 11. 30. 5.9 31.2215601000024 69.4 2215601000025 14.35 0.05 8. 40. 5.9 40.2215601000026 72.66 2215601000027 14.01 0.05 9. 34. 5.9 35.2215601000028 76.36 2215601000029 13.7 0.05 14. 21. 5.9 22.2215601000030 79.95 2215601000031 13.4 0.05 9. 22. 5.9 23.2215601000032 83.32 2215601000033 ENDDATA 16 0 2215601000034 ENDSUBENT 33 0 2215601099999 SUBENT 22156011 20060123 21752215601100001 BIB 7 12 2215601100002 REACTION (38-SR-88(N,P)37-RB-88,,SIG) 2215601100003 DECAY-DATA (37-RB-88,17.8MIN,DG,1836.0,.214) 2215601100004 SAMPLE .Weight 80 mg natural Sr, 99.999% purity 2215601100005 .Two Al monitor foils, 1. X 1. X 0.02 cm, 99.2% purity.2215601100006 DETECTOR (HPGE ) Vertical hpge, 12% efficiency, 1.75 KeV 2215601100007 resolution 2215601100008 (HPGE ) For Al monitor foil, horizontal hpge, 2215601100009 16% efficiency, 1.75 KeV resolution. 2215601100010 MONITOR (13-AL-27(N,P)12-MG-27,,SIG) Based on standard 2215601100011 Al-27(N,a) reaction in ENDF/B-V. Errors within 0.5%. 2215601100012 DECAY-MON (12-MG-27,9.46MIN,DG,843.8,.73) 2215601100013 STATUS (SPSDD,22433016) 2215601100014 ENDBIB 12 0 2215601100015 NOCOMMON 0 0 2215601100016 DATA 7 6 2215601100017 EN EN-ERR DATA ERR-1 ERR-2 ERR-T 2215601100018 MONIT 2215601100019 MEV MEV MB PER-CENT PER-CENT PER-CENT 2215601100020 MB 2215601100021 14.87 0.05 23. 12. 6.4 14.2215601100022 66.82 2215601100023 14.64 0.05 20. 11. 6.4 13.2215601100024 69.4 2215601100025 14.35 0.05 22. 10. 6.4 12.2215601100026 72.66 2215601100027 14.01 0.05 18. 11. 6.4 13.2215601100028 76.36 2215601100029 13.7 0.05 12. 21. 6.4 23.2215601100030 79.95 2215601100031 13.4 0.05 14. 11. 6.4 13.2215601100032 83.32 2215601100033 ENDDATA 16 0 2215601100034 ENDSUBENT 33 0 2215601199999 SUBENT 22156012 20060123 21752215601200001 BIB 6 11 2215601200002 REACTION (40-ZR-94(N,P)39-Y-94,,SIG) 2215601200003 DECAY-DATA (39-Y-94,18.7MIN,DG,918.8,.56) 2215601200004 SAMPLE .Weight 65 mg natural Zr, 99.8% purity 2215601200005 .Two Al monitor foils, 1. X 1. X 0.02 cm, 99.2% purity.2215601200006 DETECTOR (HPGE ) Vertical hpge, 12% efficiency, 1.75 KeV 2215601200007 resolution 2215601200008 (HPGE ) For Al monitor foil, horizontal hpge, 2215601200009 16% efficiency, 1.75 KeV resolution. 2215601200010 MONITOR (13-AL-27(N,P)12-MG-27,,SIG) Based on standard 2215601200011 Al-27(N,a) reaction in ENDF/B-V. Errors within 0.5%. 2215601200012 DECAY-MON (12-MG-27,9.46MIN,DG,843.8,.73) 2215601200013 ENDBIB 11 0 2215601200014 NOCOMMON 0 0 2215601200015 DATA 7 6 2215601200016 EN EN-ERR DATA ERR-1 ERR-2 ERR-T 2215601200017 MONIT 2215601200018 MEV MEV MB PER-CENT PER-CENT PER-CENT 2215601200019 MB 2215601200020 14.87 0.05 6.6 12. 6.1 13.2215601200021 66.82 2215601200022 14.64 0.05 7.7 10. 6.1 11.2215601200023 69.4 2215601200024 14.35 0.05 5.6 12. 6.1 13.2215601200025 72.66 2215601200026 14.01 0.05 5.7 11. 6.1 12.2215601200027 76.36 2215601200028 13.7 0.05 5.3 12. 6.1 13.2215601200029 79.95 2215601200030 13.4 0.05 4.2 10. 6.1 12.2215601200031 83.32 2215601200032 ENDDATA 16 0 2215601200033 ENDSUBENT 32 0 2215601299999 SUBENT 22156013 20060123 21752215601300001 BIB 7 17 2215601300002 REACTION (42-MO-92(N,2N)42-MO-91-G,,SIG) 2215601300003 DECAY-DATA (42-MO-91-G,15.49MIN,AR,511.,1.874) 2215601300004 SAMPLE .Weight 70 mg, 97.01% enriched, impurities: 94 (0.86%),2215601300005 95 (0.54%), 96 (0.43%), 97 (0.26%), 98 (0.51%) and 2215601300006 100 (0.40%). 2215601300007 .Two Al monitor foils, 1. X 1. X 0.02 cm, 99.2% purity.2215601300008 DETECTOR .The detected gamma was from B+ annihilation occurring 2215601300009 in the 10 mm thick acrylic plates either side of the 2215601300010 irradiated sample. 2215601300011 (HPGE ) Vertical hpge, 12% efficiency, 1.75 KeV 2215601300012 resolution 2215601300013 (HPGE ) For Al monitor foil, horizontal hpge, 2215601300014 16% efficiency, 1.75 KeV resolution. 2215601300015 MONITOR (13-AL-27(N,P)12-MG-27,,SIG) Based on standard 2215601300016 Al-27(N,a) reaction in ENDF/B-V. Errors within 0.5%. 2215601300017 DECAY-MON (12-MG-27,9.46MIN,DG,843.8,.73) 2215601300018 STATUS (SPSDD,22662008) 2215601300019 ENDBIB 17 0 2215601300020 NOCOMMON 0 0 2215601300021 DATA 7 6 2215601300022 EN EN-ERR DATA ERR-1 ERR-2 ERR-T 2215601300023 MONIT 2215601300024 MEV MEV MB PER-CENT PER-CENT PER-CENT 2215601300025 MB 2215601300026 14.87 0.05 221. 3.2 3. 4.42215601300027 66.82 2215601300028 14.64 0.05 203. 3.1 3. 4.32215601300029 69.4 2215601300030 14.35 0.05 176. 3.1 3. 4.32215601300031 72.66 2215601300032 14.01 0.05 136. 3. 3. 4.22215601300033 76.36 2215601300034 13.7 0.05 89. 3.3 3. 4.52215601300035 79.95 2215601300036 13.4 0.05 46. 3.3 3. 4.52215601300037 83.32 2215601300038 ENDDATA 16 0 2215601300039 ENDSUBENT 38 0 2215601399999 SUBENT 22156014 20060123 21752215601400001 BIB 8 17 2215601400002 REACTION (42-MO-97(N,P)41-NB-97-M,,SIG) 2215601400003 DECAY-DATA (41-NB-97-M,1.0MIN,DG,743.4,.9795) 2215601400004 SAMPLE .Weight 50 mg, 94.25% enriched, impurities: 92 (0.22%),2215601400005 94 (0.24%), 95 (0.59%), 96 (1.34%), 98 (3.07%) and 2215601400006 100 (0.30%). 2215601400007 .Two Al monitor foils, 1. X 1. X 0.02 cm, 99.2% purity.2215601400008 DETECTOR (HPGE ) Vertical hpge, 12% efficiency, 1.75 KeV 2215601400009 resolution 2215601400010 (HPGE ) For Al monitor foil, horizontal hpge, 2215601400011 16% efficiency, 1.75 KeV resolution. 2215601400012 MONITOR (13-AL-27(N,P)12-MG-27,,SIG) Based on standard 2215601400013 Al-27(N,a) reaction in ENDF/B-V. Errors within 0.5%. 2215601400014 DECAY-MON (12-MG-27,9.46MIN,DG,843.8,.73) 2215601400015 STATUS (SPSDD,22433017) 2215601400016 HISTORY (19910403A) S.W. Err-1 and err-t corrected 2215601400017 (19910523E) 2215601400018 (20060123U) Last checking has been done. 2215601400019 ENDBIB 17 0 2215601400020 NOCOMMON 0 0 2215601400021 DATA 7 6 2215601400022 EN EN-ERR DATA ERR-1 ERR-2 ERR-T 2215601400023 MONIT 2215601400024 MEV MEV MB PER-CENT PER-CENT PER-CENT 2215601400025 MB 2215601400026 1.487E+01 5.E-02 4.9 12. 6.7 14.2215601400027 6.682E+01 2215601400028 1.464E+01 5.E-02 3.4 20. 6.7 21.2215601400029 6.94E+01 2215601400030 1.435E+01 5.E-02 4.2 19. 6.7 20.2215601400031 7.266E+01 2215601400032 1.401E+01 5.E-02 3.4 17. 6.7 18.2215601400033 7.636E+01 2215601400034 1.37E+01 5.E-02 3.3 21. 6.7 22.2215601400035 7.995E+01 2215601400036 1.34E+01 5.E-02 3.6 20. 6.7 21.2215601400037 8.332E+01 2215601400038 ENDDATA 16 0 2215601400039 ENDSUBENT 38 0 2215601499999 SUBENT 22156015 20150819 22432215601500001 BIB 8 17 2215601500002 REACTION (42-MO-98(N,X)41-NB-97-M,,SIG) 2215601500003 DECAY-DATA (41-NB-97-M,1.0MIN,DG,743.4,.9795) 2215601500004 SAMPLE (42-MO-98,ENR=0.983) .Weight 70 mg, 98.3% enriched, 2215601500005 impurities: Mo-92 (0.14%), Mo-94 (0.1%), Mo-95 (0.22%),2215601500006 Mo-96 (0.34%), Mo-97 (0.58%) and Mo-100 (0.31%). 2215601500007 .Two Al monitor foils, 1. x 1. x 0.02 cm, 99.2% purity.2215601500008 DETECTOR (HPGE ) Vertical HPGe, 12% efficiency, 1.75 keV 2215601500009 resolution 2215601500010 (HPGE ) For Al monitor foil, horizontal HPGe, 2215601500011 16% efficiency, 1.75 keV resolution. 2215601500012 MONITOR (13-AL-27(N,P)12-MG-27,,SIG) Based on standard 2215601500013 Al-27(n,alpha) reaction in ENDF/B-V.Errors within 0.5%2215601500014 DECAY-MON (12-MG-27,9.46MIN,DG,843.8,.73) 2215601500015 STATUS (SPSDD,22800009) Better statistics, by 2215601500016 K.Kawade (2014-04-30) 2215601500017 HISTORY (20150819A) SD: Status 'superseded' added. Small 2215601500018 additional corrections. SF3=n+p -> X in REACTION code.2215601500019 ENDBIB 17 0 2215601500020 NOCOMMON 0 0 2215601500021 DATA 7 3 2215601500022 EN EN-ERR DATA ERR-1 ERR-2 ERR-T 2215601500023 MONIT 2215601500024 MEV MEV MB PER-CENT PER-CENT PER-CENT 2215601500025 MB 2215601500026 14.87 0.05 1.2 30. 6.7 31.2215601500027 66.82 2215601500028 14.64 0.05 1. 35. 6.7 36.2215601500029 69.4 2215601500030 14.35 0.05 0.5 40. 6.7 41.2215601500031 72.66 2215601500032 ENDDATA 10 0 2215601500033 ENDSUBENT 32 0 2215601599999 SUBENT 22156016 20060123 21752215601600001 BIB 9 16 2215601600002 REACTION (49-IN-113(N,2N)49-IN-112-M,,SIG) 2215601600003 COMMENT .See also EXFOR 22187018 2215601600004 DECAY-DATA (49-IN-112-M,20.9MIN,DG,155.,.128) 2215601600005 SAMPLE .Weight 70 mg natural in, 99.99% purity 2215601600006 .Two Al monitor foils, 1. X 1. X 0.02 cm, 99.2% purity.2215601600007 DETECTOR (HPGE ) Vertical hpge, 12% efficiency, 1.75 KeV 2215601600008 resolution 2215601600009 (HPGE ) For Al monitor foil, horizontal hpge, 2215601600010 16% efficiency, 1.75 KeV resolution. 2215601600011 MONITOR (13-AL-27(N,P)12-MG-27,,SIG) Based on standard 2215601600012 Al-27(N,a) reaction in ENDF/B-V. Errors within 0.5%. 2215601600013 DECAY-MON (12-MG-27,9.46MIN,DG,843.8,.73) 2215601600014 STATUS (SPSDD,22662010) 2215601600015 HISTORY (19910717U) S.W. Decay-data corrected, comment added 2215601600016 (19910722E) 2215601600017 (20060123U) Last checking has been done. 2215601600018 ENDBIB 16 0 2215601600019 NOCOMMON 0 0 2215601600020 DATA 7 6 2215601600021 EN EN-ERR DATA ERR-1 ERR-2 ERR-T 2215601600022 MONIT 2215601600023 MEV MEV B PER-CENT PER-CENT PER-CENT 2215601600024 MB 2215601600025 1.487E+01 5.E-02 1.41 8.1 4.3 9.22215601600026 6.682E+01 2215601600027 1.464E+01 5.E-02 1.39 6.3 4.3 7.62215601600028 6.94E+01 2215601600029 1.435E+01 5.E-02 1.32 7. 4.3 8.22215601600030 7.266E+01 2215601600031 1.401E+01 5.E-02 1.24 1.E+01 4.3 1.1E+012215601600032 7.636E+01 2215601600033 1.37E+01 5.E-02 1.32 7.2 4.3 8.42215601600034 7.995E+01 2215601600035 1.34E+01 5.E-02 1.06 6.1 4.3 7.52215601600036 8.332E+01 2215601600037 ENDDATA 16 0 2215601600038 ENDSUBENT 37 0 2215601699999 SUBENT 22156017 20060123 21752215601700001 BIB 5 6 2215601700002 REACTION (28-NI-58(N,T)27-CO-56,,SIG) 2215601700003 DECAY-DATA (27-CO-56,77.1D,DG,2598.4,.1695) 2215601700004 SAMPLE .Weight 2.6 g natural Ni, 99.7% purity. 2215601700005 DETECTOR (GE-IN) Well type Ge detector, 25% efficiency, 2215601700006 2.14 KeV resolution 2215601700007 MONITOR (28-NI-58(N,P)27-CO-58,,SIG) 2215601700008 ENDBIB 6 0 2215601700009 NOCOMMON 0 0 2215601700010 DATA 6 4 2215601700011 EN EN-ERR DATA ERR-1 ERR-2 ERR-T 2215601700012 MEV MEV MICRO-B PER-CENT PER-CENT PER-CENT 2215601700013 14.87 0.1 30.7 18. 4.7 19.2215601700014 14.63 0.1 24.8 19. 4.7 20.2215601700015 14.43 0.1 17.8 21. 4.7 26.2215601700016 14.16 0.1 11.6 25. 4.7 26.2215601700017 ENDDATA 6 0 2215601700018 ENDSUBENT 17 0 2215601799999 SUBENT 22156018 20060123 21752215601800001 BIB 5 10 2215601800002 REACTION (42-MO-92(N,N+A)40-ZR-88,,SIG) 2215601800003 DECAY-DATA (40-ZR-88,83.4D,DG,393.7,.973) 2215601800004 SAMPLE .Weight 1.0 g natural Mo, 99.95% purity. 2215601800005 DETECTOR (GE-IN) Well type Ge detector, 25% efficiency, 2215601800006 2.14 KeV resolution 2215601800007 (GELI ) Horizontal Ge(Li), 10% ) 2215601800008 efficiency, 1.92 KeV resolution ) for Nb monitor 2215601800009 (HPGE ) Vertical hpge, 23% ) reaction 2215601800010 resolution, 2.00 KeV resolution ) 2215601800011 MONITOR (41-NB-93(N,2N)41-NB-92-M,,SIG) 2215601800012 ENDBIB 10 0 2215601800013 NOCOMMON 0 0 2215601800014 DATA 6 4 2215601800015 EN EN-ERR DATA ERR-1 ERR-2 ERR-T 2215601800016 MEV MEV MICRO-B PER-CENT PER-CENT PER-CENT 2215601800017 14.87 0.05 151. 13. 3. 14.2215601800018 14.64 0.05 111. 19. 3. 20.2215601800019 14.38 0.05 94. 16. 3. 17.2215601800020 14.08 0.05 56. 25. 3. 25.2215601800021 ENDDATA 6 0 2215601800022 ENDSUBENT 21 0 2215601899999 SUBENT 22156019 20060512 21772215601900001 BIB 5 11 2215601900002 REACTION (59-PR-141(N,P)58-CE-141,,SIG) 2215601900003 SAMPLE .Weight 0.2 g, 99.999% purity. 2215601900004 DETECTOR (GE-IN) Well type Ge detector, 25% efficiency, 2215601900005 2.14 KeV resolution 2215601900006 (GELI ) Horizontal Ge(Li), 10% 2215601900007 efficiency, 1.92 KeV resolution for Nb monitor 2215601900008 (HPGE ) Vertical hpge, 23% reaction 2215601900009 resolution, 2.00 KeV resolution 2215601900010 MONITOR (41-NB-93(N,2N)41-NB-92-M,,SIG) 2215601900011 HISTORY (20060512A) Units for data changed - MICRO-B to MB, 2215601900012 according to JENDL evaluation - N.Otsuka 2215601900013 ENDBIB 11 0 2215601900014 NOCOMMON 0 0 2215601900015 DATA 6 6 2215601900016 EN EN-ERR DATA ERR-1 ERR-2 ERR-T 2215601900017 MEV MEV MB PER-CENT PER-CENT PER-CENT 2215601900018 14.87 0.05 9.73 3.4 3. 4.52215601900019 14.67 0.05 10.10 3.4 3. 4.52215601900020 14.44 0.05 9.65 3.4 3. 4.52215601900021 14.19 0.05 9.31 3.4 3. 4.52215601900022 13.89 0.05 8.72 9.5 3. 10.02215601900023 13.43 0.05 7.86 5.4 3. 6.22215601900024 ENDDATA 8 0 2215601900025 ENDSUBENT 24 0 2215601999999 SUBENT 22156020 20060512 21772215602000001 BIB 6 8 2215602000002 REACTION (59-PR-141(N,T)58-CE-139,,SIG) 2215602000003 DECAY-DATA (58-CE-139-G,137.66D,DG,165.9,.7999) 2215602000004 SAMPLE .Weight 0.2 g, 99.999% purity. 2215602000005 DETECTOR (GE-IN) Well type Ge detector, 25% efficiency, 2215602000006 2.14 KeV resolution 2215602000007 MONITOR (59-PR-141(N,P)58-CE-141,,SIG) 2215602000008 (41-NB-93(N,2N)41-NB-92-M,,SIG) 2215602000009 MONIT-REF (22156019,T.KATOH+,R,JAERI-M-89-083,1989) 2215602000010 ENDBIB 8 0 2215602000011 NOCOMMON 0 0 2215602000012 DATA 6 6 2215602000013 EN EN-ERR DATA ERR-1 ERR-2 ERR-T 2215602000014 MEV MEV MICRO-B PER-CENT PER-CENT PER-CENT 2215602000015 14.87 0.05 332. 15. 4.5 16.2215602000016 14.67 0.05 358. 14. 4.5 15.2215602000017 14.44 0.05 276. 14. 4.5 15.2215602000018 14.19 0.05 240. 14. 4.5 15.2215602000019 13.89 0.05 203. 16. 10.0 19.2215602000020 13.43 0.05 150. 18. 6.2 19.2215602000021 ENDDATA 8 0 2215602000022 ENDSUBENT 21 0 2215602099999 ENDENTRY 20 0 2215699999999