ENTRY 22208 20151214 22462220800000001 SUBENT 22208001 20151214 22462220800100001 BIB 15 45 2220800100002 INSTITUTE (2JPNJAE) Y.I., C.K. and experimental site. 2220800100003 (1USAANL) D.L.S. 2220800100004 (1USACLA) A.K. 2220800100005 REFERENCE ((S,JAERI-M-91-032,272,199103)= 2220800100006 (S,NEANDC(J)-160,272,199103)= 2220800100007 (S,INDC(JPN)-148,272,199103)) Main ref. 2220800100008 AUTHOR (Y.Ikeda,D.L.Smith,A.Kumar,C.Konno) 2220800100009 TITLE Measurements of long-lived activation cross sections 2220800100010 by 14 MeV neutrons at FNS 2220800100011 FACILITY (CCW,2JPNJAE) Fusion neutron source facility at JAERI. 2220800100012 INC-SOURCE (D-T) 2220800100013 METHOD (ACTIV) 2220800100014 DETECTOR (HPGE) The activity measurements were performed more 2220800100015 than 1.5 years after the irradiation, using a high 2220800100016 efficiency Ge detector (115% relative to a 3 by 2220800100017 3 inch NaI detector). The gamma-ray spectra were ana- 2220800100018 lyzed using the genie code system. The detector effi- 2220800100019 ciency was calibrated to a precision of about 3% 2220800100020 using standard gamma-ray sources. 2220800100021 PART-DET (DG) 2220800100022 MONITOR (41-NB-93(N,2N)41-NB-92-M,,SIG) 2220800100023 CORRECTION The activity measurements were corrected for the decay2220800100024 constant, cooling time, collection time, detector ef- 2220800100025 ficiency, isotopic abundance, gamma-ray branching ra- 2220800100026 tio, sample weight, self-absorption of gamma-rays, 2220800100027 neutron flux fluctuation during irradiation and so 2220800100028 forth. 2220800100029 ERR-ANALYS (DATA-ERR) No details given. 2220800100030 (ERR-1) Uncertainty of detector efficiency 2220800100031 COMMENT Preliminary results. Reliable results for the 2220800100032 Eu-153(n,2n)Eu-152 reaction could not be determined 2220800100033 because of a too large Eu-151(n,gamma) contribution. 2220800100034 STATUS (TABLE) Data from the Table JAERI-M-91-032,272,1991 2220800100035 There are discrepancies between data given in the text2220800100036 and the table of results. The compiled data were taken2220800100037 from the table. 2220800100038 HISTORY (19930106C) N.O. 2220800100039 (20070801A) Date and reaction SF4 in SAN 005 2220800100040 are corrected. History duplication in SAN 002-006 2220800100041 deleted - SM 2220800100042 (20070801U) Last corrections have been done. 2220800100043 (20151214A) SD: DECAY-DATA corrected in Subent 004. 2220800100044 STATUS 'superseded' added to Subents 002-006 - final 2220800100045 data published in INDC(NDS)-342,19,1996 (22658 Entry). 2220800100046 FACILITY was changed (FNS -> CCW). 2220800100047 ENDBIB 45 0 2220800100048 COMMON 1 3 2220800100049 ERR-1 2220800100050 PER-CENT 2220800100051 3. 2220800100052 ENDCOMMON 3 0 2220800100053 ENDSUBENT 52 0 2220800199999 SUBENT 22208002 20151214 22462220800200001 BIB 5 10 2220800200002 REACTION (13-AL-27(N,2N)13-AL-26-G,,SIG) 2220800200003 SAMPLE .Four sets of foil packages, placed at 0, 45, 90 and 2220800200004 135 degrees with respect to the d-beam, at a distance 2220800200005 of 30 mm from the T-target. Multiple thin Nb foils 2220800200006 were inserted in the packages for flux monitoring. The2220800200007 neutron fluence was estimated to 1-2. x 10**15/cm2. 2220800200008 DECAY-DATA (13-AL-26-G,7.16E+05YR,DG,1808.65,.9976) 2220800200009 STATUS (SPSDD,22658002) final value published. 2220800200010 HISTORY (19961204U) * * Duplicated status keyword deleted 2220800200011 (20151214U) SD: STATUS 'superseded' added. 2220800200012 ENDBIB 10 0 2220800200013 NOCOMMON 0 0 2220800200014 DATA 3 1 2220800200015 EN DATA DATA-ERR 2220800200016 MEV MB MB 2220800200017 1.49E+01 4.4E+01 5. 2220800200018 ENDDATA 3 0 2220800200019 ENDSUBENT 18 0 2220800299999 SUBENT 22208003 20151214 22462220800300001 BIB 5 15 2220800300002 REACTION (47-AG-109(N,2N)47-AG-108-M,,SIG) 2220800300003 SAMPLE Two sample packages were placed at 7 cm from the d-t 2220800300004 source. The nominal fluence was about 2.x10**14/cm2. 2220800300005 The fluence in the sample packages was monitored by 2220800300006 foils of Ni, Ti and Fe. For absolute fluence 2220800300007 determination, Nb foils were attached on both front 2220800300008 and rear surfaces of the packages. 2220800300009 DECAY-DATA (47-AG-108-M,127.YR,DG,434.0,.905) 2220800300010 STATUS (SPSDD,22658008) final data are given with corrected 2220800300011 half-life (127.yr -> 438.yr). In final publication 2220800300012 (INDC(NDS-342,19) authors mentioned:" After revising 2220800300013 half-life of 127 yr to 418 yr, the experimental data 2220800300014 becomes very consistent with the evaluation at IRK". 2220800300015 HISTORY (19961204U) * * Duplicated status keyword deleted 2220800300016 (20151214U) SD: STATUS 'superseded' added. 2220800300017 ENDBIB 15 0 2220800300018 NOCOMMON 0 0 2220800300019 DATA 3 1 2220800300020 EN DATA DATA-ERR 2220800300021 MEV MB MB 2220800300022 1.48E+01 1.91E+02 7. 2220800300023 ENDDATA 3 0 2220800300024 ENDSUBENT 23 0 2220800399999 SUBENT 22208004 20151214 22462220800400001 BIB 5 12 2220800400002 REACTION (63-EU-151(N,2N)63-EU-150-G,,SIG) 2220800400003 SAMPLE Two sample packages were placed at 7 cm from the d-t 2220800400004 source. The nominal fluence was about 2.x10**14/cm2. 2220800400005 The fluence in the sample packages was monitored by 2220800400006 foils of Ni, Ti and Fe. For absolute fluence 2220800400007 determination, Nb foils were attached on both front 2220800400008 and rear surfaces of the packages. 2220800400009 DECAY-DATA (63-EU-150-G,35.8YR,DG,333.96,.94) 2220800400010 STATUS (SPSDD,22658009) final value published. 2220800400011 HISTORY (19961204U) * * Duplicated status keyword deleted 2220800400012 (20151214A) SD: STATUS 'superseded' added. Eu-150m -> 2220800400013 Eu-150g in REACTION code and DECAY-DATA. 2220800400014 ENDBIB 12 0 2220800400015 NOCOMMON 0 0 2220800400016 DATA 3 1 2220800400017 EN DATA DATA-ERR 2220800400018 MEV MB MB 2220800400019 1.48E+01 1.127E+03 5.5E+01 2220800400020 ENDDATA 3 0 2220800400021 ENDSUBENT 20 0 2220800499999 SUBENT 22208005 20151214 22462220800500001 BIB 5 13 2220800500002 REACTION (65-TB-159(N,2N)65-TB-158,,SIG) 2220800500003 SAMPLE Two sample packages were placed at 7 cm from the d-t 2220800500004 source. The nominal fluence was about 2.x10**14/cm2. 2220800500005 The fluence in the sample packages was monitored by 2220800500006 foils of Ni, Ti and Fe. For absolute fluence 2220800500007 determination, Nb foils were attached on both front 2220800500008 and rear surfaces of the packages. 2220800500009 DECAY-DATA (65-TB-158-G,150.YR,DG,944.2,.43) 2220800500010 STATUS (SPSDD,22658011) final value published. 2220800500011 HISTORY (19961204U) * * Duplicated status keyword deleted 2220800500012 (20070801A) Reaction SF4 corrected from 65-TB-158-G 2220800500013 after N.Otsuka comments - 2007-06-08 2220800500014 (20151214U) SD: STATUS 'superseded' added. 2220800500015 ENDBIB 13 0 2220800500016 NOCOMMON 0 0 2220800500017 DATA 3 1 2220800500018 EN DATA DATA-ERR 2220800500019 MEV MB MB 2220800500020 1.48E+01 1.6E+03 8.8E+01 2220800500021 ENDDATA 3 0 2220800500022 ENDSUBENT 21 0 2220800599999 SUBENT 22208006 20151214 22462220800600001 BIB 5 12 2220800600002 REACTION (72-HF-179(N,2N)72-HF-178-M2,,SIG) 2220800600003 SAMPLE Two sample packages were placed at 7 cm from the d-t 2220800600004 source. The nominal fluence was about 2.x10**14/cm2. 2220800600005 The fluence in the sample packages was monitored by 2220800600006 foils of Ni, Ti and Fe. For absolute fluence 2220800600007 determination, Nb foils were attached on both front 2220800600008 and rear surfaces of the packages. 2220800600009 DECAY-DATA (72-HF-178-M2,31.YR,DG,325.56,.941) 2220800600010 STATUS (SPSDD,22658014) final value published. 2220800600011 HISTORY (19961204U) * * Duplicated STATUS keyword deleted 2220800600012 (20151214A) SD: STATUS 'superseded' added. Hf-178m -> 2220800600013 Hf-178m2 in REACTION code and DECAY-DATA. 2220800600014 ENDBIB 12 0 2220800600015 NOCOMMON 0 0 2220800600016 DATA 3 1 2220800600017 EN DATA DATA-ERR 2220800600018 MEV MB MB 2220800600019 1.48E+01 6. 3.E-01 2220800600020 ENDDATA 3 0 2220800600021 ENDSUBENT 20 0 2220800699999 ENDENTRY 6 0 2220899999999