ENTRY 22860 20180831 22702286000000001 SUBENT 22860001 20180831 22702286000100001 BIB 14 40 2286000100002 TITLE Measurement method of activation cross-sections of 2286000100003 reactions producing short-lived nuclei with 14-MeV 2286000100004 neutrons. 2286000100005 AUTHOR (K.Kawade,H.Sakane,Y.Kasugai,M.Shibata,T.Iida, 2286000100006 A.Takahashi,T.Fukahori) 2286000100007 INSTITUTE (2JPNNAG) 2286000100008 (2JPNOSA) 2286000100009 (2JPNJAE) 2286000100010 REFERENCE (J,NIM/A,496,183,2003) 2286000100011 SAMPLE Al-foil of 10-mm*10-mm*0.2-mm thick was used. 2286000100012 INC-SOURCE (D-T) The d-t-neutrons were generated by bombarding a 2286000100013 water-cooled 3.7 x 10**11-Bq-tritiated titanium target 2286000100014 with a 300-keV deuteron beam. 2286000100015 DETECTOR (HPGE) 2286000100016 MONITOR (13-AL-27(N,A)11-NA-24,,SIG).ENDF/B-VI summary 2286000100017 documentation, BNL-NCS-17541, NNDC, BNL,1991. 2286000100018 MONIT-REF (,P.F.Rose+,R,BNL-NCS-17541,1991) 2286000100019 FACILITY (CCW,2JPNOSA) The intense 14-MeV neutron source 2286000100020 facility of OSAKA University-OKTAVIAN. 2286000100021 METHOD (ACTIV) 2286000100022 CORRECTION *By authors*.Neutron irradiation fields was noted and 2286000100023 induced activities was measured including the 2286000100024 contributions of scattered low-energy neutrons, the 2286000100025 fluctuation of the neutron fluence rate during 2286000100026 irradiation, the true coincidence sum effect, the 2286000100027 random coincidence sum effect, the deviation in the 2286000100028 measuring position due to finite sample thickness, 2286000100029 the self-absorption of the gamma-ray in the sample 2286000100030 materials and the interference reactions producing the2286000100031 same radionuclides or the ones emitting the gamma-ray 2286000100032 with the same energy interest. 2286000100033 ERR-ANALYS (ERR-T) The total errors 2286000100034 The main source of the total error is the standard 2286000100035 cross-section of 27Al (n,alpha) 24Na (ENDF/B-VI). 2286000100036 HISTORY (20041126C) SM, SB 2286000100037 (20041222U) Last checking has been done. 2286000100038 (20131212A) SD: Subent 2 deleted according to letter 2286000100039 from author: Dr. K.Kawade. ERR-ANALYS updated. 2286000100040 (20180831U) SD: ERR-ANALYS was updated according to 2286000100041 remark from N.Otsuka. 2286000100042 ENDBIB 40 0 2286000100043 COMMON 1 3 2286000100044 ERR-T 2286000100045 PER-CENT 2286000100046 3.6 2286000100047 ENDCOMMON 3 0 2286000100048 ENDSUBENT 47 0 2286000199999 NOSUBENT 22860002 20131212 22382286000200001 SUBENT 22860003 20180831 22702286000300001 BIB 3 4 2286000300002 REACTION (13-AL-27(N,P)12-MG-27,,SIG) 2286000300003 ERR-ANALYS (ERR-1) Error in detector efficiency 2286000300004 (ERR-2) Uncertainty in monitor cross section: 3% 2286000300005 STATUS (TABLE) Data sent via internet, O.Naohiko, 2005-02-10 2286000300006 ENDBIB 4 0 2286000300007 COMMON 2 3 2286000300008 ERR-1 ERR-2 2286000300009 PER-CENT PER-CENT 2286000300010 1.5 3.0 2286000300011 ENDCOMMON 3 0 2286000300012 DATA 2 6 2286000300013 EN DATA 2286000300014 MEV MB 2286000300015 13.38 80.23 2286000300016 13.69 78.24 2286000300017 14.02 73.65 2286000300018 14.36 68.31 2286000300019 14.65 66.31 2286000300020 14.88 63.98 2286000300021 ENDDATA 8 0 2286000300022 ENDSUBENT 21 0 2286000399999 ENDENTRY 3 0 2286099999999