ENTRY 30104 20080208 31263010400000001 SUBENT 30104001 20080208 31263010400100001 BIB 14 45 3010400100002 INSTITUTE (3POLIBJ,3POLWWA) 3010400100003 REFERENCE (J,NP/A,204,121,197304) full paper 3010400100004 (R,INR-1417/I/PL,197208) includes other reactions,see 3010400100005 Exfor 30151. 3010400100006 (P,INR-1172,1970)method,table,cfd theory 3010400100007 (P,INR-1197/I/PL,10,197005) identical to INR-1172. 3010400100008 (J,APP/B,1,271,1970) identical to INR-1172 3010400100009 (C,72BUD,190,197207) short paper,no data, graph 3010400100010 AUTHOR (P.Decowski,W.Grochulski,J.Karolyi,A.Marcinkowsky, 3010400100011 J.Piotrowski,E.Saad,K.Siwek,Z.Wilhelmi) 3010400100012 TITLE Isomeric cross section ratios and total cross sections 3010400100013 for the In-113(n,2n) reaction in the neutron energy 3010400100014 range 13-18 MeV 3010400100015 FACILITY (VDG) 3MeV Van de Graaff accelerator 3010400100016 INC-SOURCE (D-T) T(d,n)alpha reaction 3010400100017 INC-SPECT The energy spreads were determined taking into account 3010400100018 .The effective distribution of incident neutrons 3010400100019 .The irradiation geometry 3010400100020 .The neutron energy dependence on the emission angle 3010400100021 .The deuteron energy loss in the tritium target 3010400100022 SAMPLE Indium oxide enriched to 80% 3010400100023 METHOD (ACTIV) The 14.3 min and the 20.7 min beta+ activities 3010400100024 of the residual nucleus allowed to determine the 3010400100025 isomeric ratio by measuring the annihilation quanta. 3010400100026 DETECTOR (NAICR) Scintillation spectrometer with a 3x3 inch 3010400100027 NaI crystal. The photo-peak efficiencies were taken 3010400100028 from C.E Crouthamel(applied gamma-ray spectrometry, 3010400100029 Pergamon Press(1960)) 3010400100030 PART-DET (AR) Annihilation radiation 3010400100031 STATUS (TABLE) Data taken from Nucl.Phys.A204,Tables 2,4. 3010400100032 (APRVD) Approved by Marcinkowski (19731002) 3010400100033 HISTORY (19720117C) CA. 3010400100034 (19730731A) CA..New reference was added= Nucl.Phys.A2043010400100035 .Numerical values of errors in subent.0033010400100036 were changed according to Nucl.Phys.A2043010400100037 .Numerical values of standard were added 3010400100038 .Other minor changes. 3010400100039 (19731016U) CA. .Status approved added 3010400100040 .References added= Acta Phys.Pol.B1(1970)3010400100041 271 and 72Bud(1972)190. 3010400100042 (19791023U) KO.-One reference added.- 3010400100043 (20080208A) BIB section updated 3010400100044 CORRECTION The monitoring of the neutron flux is made by counting 3010400100045 in a CsI scintillator the protons recoiled from a 3010400100046 polyethylene foil 3010400100047 ENDBIB 45 0 3010400100048 NOCOMMON 0 0 3010400100049 ENDSUBENT 48 0 3010400199999 SUBENT 30104002 20080208 31263010400200001 BIB 3 4 3010400200002 REACTION (49-IN-113(N,2N)49-IN-112-G/M,,SIG/RAT) 3010400200003 DECAY-DATA (49-IN-112-G,14.3MIN) half-lives were 3010400200004 (49-IN-112-M,20.7MIN) assumed by author 3010400200005 ERR-ANALYS (ERR-S) statistical errors only 3010400200006 ENDBIB 4 0 3010400200007 NOCOMMON 0 0 3010400200008 DATA 4 10 3010400200009 EN EN-RSL DATA ERR-S 3010400200010 MEV MEV NO-DIM NO-DIM 3010400200011 1.2980E+01 1.5000E-01 2.3000E-01 6.0000E-02 3010400200012 1.3330E+01 1.0000E-01 1.3000E-01 1.0000E-02 3010400200013 1.3860E+01 9.0000E-02 1.5000E-01 1.0000E-02 3010400200014 1.4520E+01 1.2000E-01 6.0000E-02 1.0000E-02 3010400200015 1.5170E+01 1.4000E-01 6.0000E-02 1.0000E-02 3010400200016 1.5980E+01 1.9000E-01 1.0000E-01 2.0000E-02 3010400200017 1.6280E+01 1.6000E-01 1.3000E-01 2.0000E-02 3010400200018 1.6870E+01 2.5000E-01 1.7000E-01 4.0000E-02 3010400200019 1.7370E+01 2.4000E-01 1.6000E-01 3.0000E-02 3010400200020 1.7830E+01 1.3000E-01 1.4000E-01 2.0000E-02 3010400200021 ENDDATA 12 0 3010400200022 ENDSUBENT 21 0 3010400299999 SUBENT 30104003 20080208 31263010400300001 BIB 3 27 3010400300002 REACTION (49-IN-113(N,2N)49-IN-112,,SIG) 3010400300003 MONITOR (30-ZN-64(N,2N)30-ZN-63,,SIG) 3010400300004 En stand 3010400300005 MeV mb 3010400300006 13.0 42. 3010400300007 13.3 75. 3010400300008 13.5 80. 3010400300009 14.2 142. 3010400300010 14.6 183. 3010400300011 15.0 200. 3010400300012 15.3 240. 3010400300013 15.5 240. 3010400300014 15.7 250. 3010400300015 16.0 260. 3010400300016 16.4 290. 3010400300017 16.8 310. 3010400300018 17.0 320. 3010400300019 17.5 330. 3010400300020 18.0 340. 3010400300021 ERR-ANALYS (ERR-T) errors contain statistical and systematic 3010400300022 errors which consist of uncertainties 3010400300023 .In the integration of the pulse-height spectrum 3010400300024 .Caused by fluctuations of the beam current 3010400300025 .Of sample weight and composition 3010400300026 .Of counter efficiency 3010400300027 .Of the gamma-ray attenuation in the sample 3010400300028 .Of the cross section of the monitoring reaction 3010400300029 ENDBIB 27 0 3010400300030 NOCOMMON 0 0 3010400300031 DATA 4 11 3010400300032 EN EN-RSL DATA ERR-T 3010400300033 MEV MEV MB MB 3010400300034 1.2980E+01 1.5000E-01 1.3690E+03 2.4600E+02 3010400300035 1.3330E+01 1.0000E-01 1.3560E+03 2.1500E+02 3010400300036 1.3860E+01 9.0000E-02 1.5030E+03 2.3600E+02 3010400300037 1.4520E+01 1.2000E-01 1.5270E+03 2.3700E+02 3010400300038 1.5170E+01 1.4000E-01 1.5570E+03 2.3400E+02 3010400300039 1.5440E+01 1.6000E-01 1.7250E+03 2.4400E+02 3010400300040 1.5980E+01 1.9000E-01 1.4890E+03 2.4500E+02 3010400300041 1.6280E+01 1.6000E-01 1.3770E+03 2.2800E+02 3010400300042 1.6870E+01 2.5000E-01 1.4620E+03 3.0600E+02 3010400300043 1.7370E+01 2.4000E-01 1.4080E+03 2.6400E+02 3010400300044 1.7830E+01 1.3000E-01 1.4450E+03 2.1500E+02 3010400300045 ENDDATA 13 0 3010400300046 ENDSUBENT 45 0 3010400399999 ENDENTRY 3 0 3010499999999