ENTRY 30106 20080208 31263010600000001 SUBENT 30106001 20080208 31263010600100001 BIB 12 18 3010600100002 INSTITUTE (3CRORBZ) 3010600100003 REFERENCE (J,NP/A,154,273,1970)full information 3010600100004 (P,INDC(SEC)-18,189,197108) small report 3010600100005 AUTHOR (S.Lulic,P.Strohal,I.Slaus) 3010600100006 TITLE The study of (n,2p) reactions at 14 MeV 3010600100007 FACILITY (CCW) 200 keV Cockcroft Walton generator 3010600100008 INC-SOURCE (D-T) d+t reaction 3010600100009 SAMPLE Powder- thin wall-plastic box, 5 cm in diameter and 1cm3010600100010 high filled with powdered target material 3010600100011 METHOD (ACTIV) activation method. 3010600100012 PART-DET (DG) decay gammas 3010600100013 STATUS (TABLE) Data are taken from Tables in Nucl.Phys.A154 3010600100014 HISTORY (19720421C) CA. 3010600100015 (20080208A) BIB section updated 3010600100016 CORRECTION The cross sections were determined taking into account 3010600100017 all necessary corrections, such as branching ratios and3010600100018 the efficiency of spectrometer as a function of the 3010600100019 gamma-ray energy. 3010600100020 ENDBIB 18 0 3010600100021 COMMON 2 3 3010600100022 EN EN-RSL 3010600100023 MEV MEV 3010600100024 1.4600E+01 2.0000E-01 3010600100025 ENDCOMMON 3 0 3010600100026 ENDSUBENT 25 0 3010600199999 SUBENT 30106002 20080208 31263010600200001 BIB 6 10 3010600200002 REACTION (19-K-41(N,2P)17-CL-40,,SIG) 3010600200003 SAMPLE salt- KNO3 3010600200004 METHOD After irradiation, the chemical separation of Z-2 3010600200005 elements from predominantly Z and Z-1 materials was 3010600200006 performed. 3010600200007 DETECTOR (GELI) 20 cm3 Ge(Li) detector coupled to a PDP-8 used 3010600200008 as a 1024-channel analyser 3010600200009 MONITOR (19-K-41(N,A)17-CL-38,,SIG) 3010600200010 Value taken from Bramlitt,Phys.Rev.131 (1963)2649 3010600200011 ERR-ANALYS Datum is an upper limit,no further information 3010600200012 ENDBIB 10 0 3010600200013 COMMON 2 3 3010600200014 MONIT MONIT-ERR 3010600200015 MB MB 3010600200016 3.0000E+01 6.0000E+00 3010600200017 ENDCOMMON 3 0 3010600200018 DATA 1 1 3010600200019 DATA-MAX 3010600200020 MICRO-B 3010600200021 5.0000E+01 3010600200022 ENDDATA 3 0 3010600200023 ENDSUBENT 22 0 3010600299999 SUBENT 30106003 20080208 31263010600300001 BIB 5 7 3010600300002 REACTION (22-TI-50(N,2P)20-CA-49,,SIG) 3010600300003 SAMPLE oxide- TiO2 3010600300004 DETECTOR (NAICR) 7.6X7.6 cm NaI(Tl) scintillation counter in 3010600300005 connection with a 256-channel analyser 3010600300006 MONITOR (22-TI-50(N,P)21-SC-50,,SIG) 3010600300007 Value taken from Bramlitt,Phys.Rev.131 (1963)2649 3010600300008 ERR-ANALYS Datum is an upper limit,no further information 3010600300009 ENDBIB 7 0 3010600300010 COMMON 2 3 3010600300011 MONIT MONIT-ERR 3010600300012 MB MB 3010600300013 2.8000E+01 6.0000E+00 3010600300014 ENDCOMMON 3 0 3010600300015 DATA 1 1 3010600300016 DATA-MAX 3010600300017 MICRO-B 3010600300018 1.0000E+02 3010600300019 ENDDATA 3 0 3010600300020 ENDSUBENT 19 0 3010600399999 SUBENT 30106004 20080208 31263010600400001 BIB 5 10 3010600400002 REACTION (25-MN-55(N,2P)23-V-54,,SIG) 3010600400003 SAMPLE Oxide- MnO2 3010600400004 DETECTOR (GELI) 20 cm3 Ge(Li) detector coupled to a PDP-8 used 3010600400005 as a 1024-channel analyser 3010600400006 MONITOR (25-MN-55(N,A)23-V-52,,SIG) 3010600400007 Value taken from= 3010600400008 .Kumabe,J.Phys.Soc.Jap.13(1958)325 3010600400009 .Weigold,Austral.J.Phys.13(1960)186 3010600400010 .Husain,J.Inorg.Nucl.Chem.30(1968)3145 3010600400011 ERR-ANALYS Datum is an upper limit,no further information 3010600400012 ENDBIB 10 0 3010600400013 COMMON 1 3 3010600400014 MONIT 3010600400015 MB 3010600400016 3.3000E+01 3010600400017 ENDCOMMON 3 0 3010600400018 DATA 1 1 3010600400019 DATA-MAX 3010600400020 MICRO-B 3010600400021 1.1000E+02 3010600400022 ENDDATA 3 0 3010600400023 ENDSUBENT 22 0 3010600499999 SUBENT 30106005 20080208 31263010600500001 BIB 6 10 3010600500002 REACTION (37-RB-87(N,2P)35-BR-86,,SIG) 3010600500003 SAMPLE Salt- RbNO3 3010600500004 METHOD After irradiation, the chemical separation of Z-2 3010600500005 elements from predominantly Z and Z-1 materials was 3010600500006 performed. 3010600500007 DETECTOR (GELI) 20 cm3 Ge(Li) detector coupled to a PDP-8 used 3010600500008 as a 1024-channel analyser 3010600500009 MONITOR (37-RB-87(N,A)35-BR-84,,SIG) 3010600500010 Value taken from Strohal,Nucl.Phys.30 (1962)49 3010600500011 ERR-ANALYS Datum is an upper limit,no further information 3010600500012 ENDBIB 10 0 3010600500013 COMMON 2 3 3010600500014 MONIT MONIT-ERR 3010600500015 MB MB 3010600500016 5.9000E+01 1.2000E+01 3010600500017 ENDCOMMON 3 0 3010600500018 DATA 1 1 3010600500019 DATA-MAX 3010600500020 MICRO-B 3010600500021 5.0000E+00 3010600500022 ENDDATA 3 0 3010600500023 ENDSUBENT 22 0 3010600599999 SUBENT 30106006 20080208 31263010600600001 BIB 6 17 3010600600002 REACTION (21-SC-45(N,2P)19-K-44,,SIG) 3010600600003 SAMPLE Oxide- Sc2-O3 3010600600004 METHOD After irradiation, the chemical separation of Z-2 3010600600005 elements from predominantly Z and Z-1 materials was 3010600600006 performed. 3010600600007 DETECTOR (GELI) 20 cm3 Ge(Li) detector coupled to a PDP-8 used 3010600600008 as a 1024-channel analyser 3010600600009 MONITOR (21-SC-45(N,A)19-K-42,,SIG) 3010600600010 Value taken from Bramlitt,Phys.Rev.131 (1963)2649 3010600600011 ERR-ANALYS (ERR-T) data error includes uncertainties from= 3010600600012 .Statistics(main error) 3010600600013 .Photopeak extraction 3010600600014 .Impurities 3010600600015 .Crystal efficiency 3010600600016 .Branching ratios 3010600600017 .Standard cross-section 3010600600018 .Etc... 3010600600019 ENDBIB 17 0 3010600600020 NOCOMMON 0 0 3010600600021 DATA 4 1 3010600600022 DATA ERR-T MONIT MONIT-ERR 3010600600023 MICRO-B MICRO-B MB MB 3010600600024 2.5000E+01 1.0000E+01 6.3000E+01 1.2000E+01 3010600600025 ENDDATA 3 0 3010600600026 ENDSUBENT 25 0 3010600699999 SUBENT 30106007 20080208 31263010600700001 BIB 5 14 3010600700002 REACTION (23-V-51(N,2P)21-SC-50,,SIG) 3010600700003 SAMPLE Oxide- V2-O5 containing 1.4% of TiO2 3010600700004 (percentage determined by studying the (n,2n) reaction3010600700005 on the Ti-46 impurity in the target) 3010600700006 DETECTOR (GELI) 20 cm3 Ge(Li) detector coupled to a PDP-8 used 3010600700007 as a 1024-channel analyser 3010600700008 MONITOR (23-V-51(N,P)22-TI-51,,SIG) 3010600700009 Value taken from Bramlitt,Phys.Rev.131 (1963)2649 3010600700010 ERR-ANALYS (DATA-ERR)Due to the parasitic reaction 50Ti(n,p)50Sc 3010600700011 which masked the investigated (n,2p) reaction on V-51, 3010600700012 the uncertainty is about 100%. Additional 3010600700013 uncertainty comes from the fact that chemical 3010600700014 separation of Z-2 elements from predominantly Z and Z-13010600700015 materials was not performed 3010600700016 ENDBIB 14 0 3010600700017 COMMON 2 3 3010600700018 MONIT MONIT-ERR 3010600700019 MB MB 3010600700020 5.5000E+01 1.2000E+01 3010600700021 ENDCOMMON 3 0 3010600700022 DATA 2 1 3010600700023 DATA DATA-ERR 3010600700024 MICRO-B PER-CENT 3010600700025 6.0000E+01 1.0000E+02 3010600700026 ENDDATA 3 0 3010600700027 ENDSUBENT 26 0 3010600799999 SUBENT 30106008 20080208 31263010600800001 BIB 6 17 3010600800002 REACTION (33-AS-75(N,2P)31-GA-74,,SIG) 3010600800003 SAMPLE Oxide- As2-O3 3010600800004 METHOD After irradiation, the chemical separation of Z-2 3010600800005 elements from predominantly Z and Z-1 materials was 3010600800006 performed. 3010600800007 DETECTOR (GELI) 20 cm3 Ge(Li) detector coupled to a PDP-8 used 3010600800008 as a 1024-channel analyser 3010600800009 MONITOR (33-AS-75(N,A)31-GA-72,,SIG) 3010600800010 Value taken from Bramlitt,Phys.Rev.131 (1963)2649 3010600800011 ERR-ANALYS (DATA-ERR) data error includes uncertainties from= 3010600800012 .Statistics(main error) 3010600800013 .Photopeak extraction 3010600800014 .Impurities 3010600800015 .Crystal efficiency 3010600800016 .Branching ratios 3010600800017 .Standard cross-section 3010600800018 .Etc... 3010600800019 ENDBIB 17 0 3010600800020 COMMON 2 3 3010600800021 MONIT MONIT-ERR 3010600800022 MB MB 3010600800023 9.3000E+00 3.1000E+00 3010600800024 ENDCOMMON 3 0 3010600800025 DATA 2 1 3010600800026 DATA DATA-ERR 3010600800027 MICRO-B MICRO-B 3010600800028 5.2000E+01 2.9000E+01 3010600800029 ENDDATA 3 0 3010600800030 ENDSUBENT 29 0 3010600899999 SUBENT 30106009 20080208 31263010600900001 BIB 6 18 3010600900002 REACTION (39-Y-89(N,2P)37-RB-88,,SIG) 3010600900003 SAMPLE Salt- Y(NO3)3 3010600900004 METHOD After irradiation, performed using the sandwich 3010600900005 arrangement= Al foil-Y(NO3)3-Al foil, the chemical 3010600900006 separation of Z-2 elements from predominantly Z and Z-13010600900007 materials was made. 3010600900008 DETECTOR (GELI) 20 cm3 Ge(Li) detector coupled to a PDP-8 used 3010600900009 as a 1024-channel analyser 3010600900010 MONITOR (13-AL-27(N,P)12-MG-27,,SIG) 3010600900011 Value taken from Kantele,Nucl.Phys.35,353 (1962) 3010600900012 ERR-ANALYS (DATA-ERR) data error includes uncertainties from= 3010600900013 .Statistics(main error) 3010600900014 .Photopeak extraction 3010600900015 .Impurities 3010600900016 .Crystal efficiency 3010600900017 .Branching ratios 3010600900018 .Standard cross-section 3010600900019 .Etc... 3010600900020 ENDBIB 18 0 3010600900021 COMMON 2 3 3010600900022 MONIT MONIT-ERR 3010600900023 MB MB 3010600900024 8.2000E+01 1.0000E+01 3010600900025 ENDCOMMON 3 0 3010600900026 DATA 2 1 3010600900027 DATA DATA-ERR 3010600900028 MICRO-B MICRO-B 3010600900029 5.0000E+01 4.0000E+01 3010600900030 ENDDATA 3 0 3010600900031 ENDSUBENT 30 0 3010600999999 SUBENT 30106010 20080208 31263010601000001 BIB 6 17 3010601000002 REACTION (41-NB-93(N,2P)39-Y-92,,SIG) 3010601000003 SAMPLE Oxide- Nb2-O5 3010601000004 METHOD After irradiation, the chemical separation of Z-2 3010601000005 elements from predominantly Z and Z-1 materials was 3010601000006 performed. 3010601000007 DETECTOR (GELI) 20 cm3 Ge(Li) detector coupled to a PDP-8 used 3010601000008 as a 1024-channel analyser 3010601000009 MONITOR (41-NB-93(N,A)39-Y-90,,SIG) Value taken 3010601000010 from Bramlitt,J.Inorg.Nucl.Chem.24(1962)1321 3010601000011 ERR-ANALYS (DATA-ERR) Data error includes uncertainties from= 3010601000012 .Statistics(main error) 3010601000013 .Photopeak extraction 3010601000014 .Impurities 3010601000015 .Crystal efficiency 3010601000016 .Branching ratios 3010601000017 .Standard cross-section 3010601000018 .Etc... 3010601000019 ENDBIB 17 0 3010601000020 COMMON 2 3 3010601000021 MONIT MONIT-ERR 3010601000022 MB MB 3010601000023 5.9000E+00 2.0000E+00 3010601000024 ENDCOMMON 3 0 3010601000025 DATA 2 1 3010601000026 DATA DATA-ERR 3010601000027 MICRO-B MICRO-B 3010601000028 5.0000E+01 2.0000E+01 3010601000029 ENDDATA 3 0 3010601000030 ENDSUBENT 29 0 3010601099999 SUBENT 30106011 20080208 31263010601100001 BIB 6 17 3010601100002 REACTION (55-CS-133(N,2P)53-I-132,,SIG) 3010601100003 SAMPLE Salt- CsNO3 3010601100004 METHOD After irradiation, the chemical separation of Z-2 3010601100005 elements from predominantly Z and Z-1 materials was 3010601100006 performed. 3010601100007 DETECTOR (GELI) 20 cm3 Ge(Li) detector coupled to a PDP-8 used 3010601100008 as a 1024-channel analyser 3010601100009 MONITOR (55-CS-133(N,A)53-I-130,,SIG) 3010601100010 Value taken from Bramlitt,Phys.Rev.131 (1963)2649 3010601100011 ERR-ANALYS (DATA-ERR) data error includes uncertainties from= 3010601100012 .Statistics(main error) 3010601100013 .Photopeak extraction 3010601100014 .Impurities 3010601100015 .Crystal efficiency 3010601100016 .Branching ratios 3010601100017 .Standard cross-section 3010601100018 .Etc... 3010601100019 ENDBIB 17 0 3010601100020 COMMON 2 3 3010601100021 MONIT MONIT-ERR 3010601100022 MB MB 3010601100023 1.0000E+00 9.0000E-01 3010601100024 ENDCOMMON 3 0 3010601100025 DATA 2 1 3010601100026 DATA DATA-ERR 3010601100027 MICRO-B MICRO-B 3010601100028 2.5000E+01 2.0000E+01 3010601100029 ENDDATA 3 0 3010601100030 ENDSUBENT 29 0 3010601199999 SUBENT 30106012 20080208 31263010601200001 BIB 6 17 3010601200002 REACTION (57-LA-139(N,2P)55-CS-138,,SIG) 3010601200003 SAMPLE Salt- La(NO3)3 3010601200004 METHOD After irradiation, the chemical separation of Z-2 3010601200005 elements from predominantly Z and Z-1 materials was 3010601200006 performed. 3010601200007 DETECTOR (GELI) 20 cm3 Ge(Li) detector coupled to a PDP-8 used 3010601200008 as a 1024-channel analyser 3010601200009 MONITOR (57-LA-139(N,A)55-CS-136,,SIG) 3010601200010 Value taken from Coleman,Proc.Phys.Soc.73(1959)215 3010601200011 ERR-ANALYS (DATA-ERR) data error includes uncertainties from= 3010601200012 .Statistics(main error) 3010601200013 .Photopeak extraction 3010601200014 .Impurities 3010601200015 .Crystal efficiency 3010601200016 .Branching ratios 3010601200017 .Standard cross-section 3010601200018 .Etc... 3010601200019 ENDBIB 17 0 3010601200020 COMMON 2 3 3010601200021 MONIT MONIT-ERR 3010601200022 MB MB 3010601200023 1.8700E+00 1.9000E-01 3010601200024 ENDCOMMON 3 0 3010601200025 DATA 2 1 3010601200026 DATA DATA-ERR 3010601200027 MICRO-B MICRO-B 3010601200028 3.0000E+01 2.0000E+01 3010601200029 ENDDATA 3 0 3010601200030 ENDSUBENT 29 0 3010601299999 ENDENTRY 12 0 3010699999999