ENTRY 30116 20080208 31263011600000001 SUBENT 30116001 20080208 31263011600100001 BIB 12 27 3011600100002 TITLE In-113(n,n'g)In-113m and Rh-103(n,n'g)Rh-103m cross- 3011600100003 sections for fast neutrons 3011600100004 AUTHOR (A.Pazsit,J.Csikai) 3011600100005 INSTITUTE (3HUNKOS) 3011600100006 EXP-YEAR (1971) 3011600100007 REFERENCE (J,YF,15,412,197203)In Russian,full information, table 3011600100008 (J,SNP,15,232,197209) English translation of Yad.Fiz.153011600100009 FACILITY (CCW) 200 kV accelerator 3011600100010 INC-SOURCE (D-D) d-d reaction 3011600100011 (D-T) d-t reaction 3011600100012 METHOD (ACTIV) Activation method 3011600100013 CORRECTION Low energy gamma rays absorption in the sample was 3011600100014 taken into account. 3011600100015 ERR-ANALYS Not given 3011600100016 STATUS (TABLE) Data taken from Yadernaya Fisika 15(1972)412 3011600100017 (APRVD) Approved by Peto (5/9/1972) 3011600100018 HISTORY (19710212C) HDL. 3011600100019 (19720927A) CA. New reference, new informations and 3011600100020 status approved added. 3011600100021 (19730822A) CA. English translation added 3011600100022 keyword 'en-sec' deleted 3011600100023 other minor alterations 3011600100024 (19741021A) CA. - Correction made in subentry 3. 3011600100025 (19880531A) TMK Codes of iso-quant changed to reaction,3011600100026 standard changed to monitor and cosmetic 3011600100027 corrections. 3011600100028 (20080208A) BIB section updated 3011600100029 ENDBIB 27 0 3011600100030 NOCOMMON 0 0 3011600100031 ENDSUBENT 30 0 3011600199999 SUBENT 30116002 20080208 31263011600200001 BIB 8 11 3011600200002 REACTION (49-IN-113(N,INL)49-IN-113-M,,SIG) 3011600200003 SAMPLE Thickness of indium target = 302 mg/cm2 3011600200004 DETECTOR (GELI) 28 cm3 Ge(Li) detector with a resolution of 5keV3011600200005 at 1.33MeV 3011600200006 DECAY-DATA (49-IN-113-M,98.5MIN,DG,393.) measured by author. 3011600200007 MONITOR (49-IN-115(N,INL)49-IN-115-M,,SIG) 3011600200008 DECAY-MON (49-IN-115-M,270.MIN,DG,335.) 3011600200009 MONIT-REF (11421004,H.O.Menlove+,J,PR,163,1308,1967) for 2.8 MeV 3011600200010 FLAG (1.) at 2.8 MeV the standard was taken from H.O.Menlove3011600200011 and al. Phys.Rev.163(1967)1308. 3011600200012 (2.) at 14.7 MeV data were taken from Subent 004 3011600200013 ENDBIB 11 0 3011600200014 NOCOMMON 0 0 3011600200015 DATA 6 2 3011600200016 EN DATA DATA-ERR MONIT MONIT-ERR FLAG 3011600200017 MEV MB MB MB MB NO-DIM 3011600200018 2.8 260. 25. 340. 30. 1. 3011600200019 14.7 66. 5. 63. 4. 2. 3011600200020 ENDDATA 4 0 3011600200021 ENDSUBENT 20 0 3011600299999 SUBENT 30116003 20080208 31263011600300001 BIB 9 19 3011600300002 REACTION (45-RH-103(N,INL)45-RH-103-M,,SIG) 3011600300003 REFERENCE (P,INDC(HUN)-1,2,197004) Very brief progress-report 3011600300004 SAMPLE Thickness of rhodium target = 123 mg/cm2 3011600300005 DETECTOR Si(Li) detector with following characteristics = 3011600300006 .Surface = 1 cm2 3011600300007 .Depth of sensitive layer = 2.2 Mm 3011600300008 .Resolution = 5.5 keV for the l-shell X-rays 3011600300009 of Am-241. 3011600300010 DECAY-DATA (45-RH-103-M,57.5MIN,DG,40.) measured by author. 3011600300011 MONITOR (49-IN-115(N,INL)49-IN-115-M,,SIG) 3011600300012 DECAY-MON (49-IN-113-M,98.5MIN,DG,393.) measured by author. 3011600300013 COMMENT Results with high resolution in Jour. of Appl.Radiat. 3011600300014 Isotop. Vol. 26, p. 621 0ct.1975 were entered in 3011600300015 Exfor as 30266. 3011600300016 HISTORY (19741021A) CA. -Numerical value of standard (intensity3011600300017 of the K X-rays of In-115m) and self- 3011600300018 absorption correction were corrected, 3011600300019 hence the new data. 3011600300020 (19760318U) KO. -Add new ref. and note.- 3011600300021 ENDBIB 19 0 3011600300022 NOCOMMON 0 0 3011600300023 DATA 5 1 3011600300024 EN DATA DATA-ERR MONIT MONIT-ERR 3011600300025 MEV MB MB MB MB 3011600300026 14.7 211. 19. 63. 4. 3011600300027 ENDDATA 3 0 3011600300028 ENDSUBENT 27 0 3011600399999 SUBENT 30116004 20080208 31263011600400001 BIB 7 10 3011600400002 REACTION (49-IN-115(N,INL)49-IN-115-M,,SIG) 3011600400003 DECAY-DATA (49-IN-115-M,270.MIN,DG,335.) 3011600400004 MONITOR (13-AL-27(N,A)11-NA-24,,SIG) 3011600400005 MONIT-REF (,Z.Body+,T,BOGY,1967) for Al-27(n,apha) cross- 3011600400006 section value was taken from Z.Body's thesis (Kossuth 3011600400007 University,1972)3011600400008 SAMPLE Thickness of indium target = 302 mg/cm2 3011600400009 DETECTOR (GELI) 28 cm3 Ge(Li) detector with a resolution of 5keV3011600400010 at 1.33MeV 3011600400011 REL-REF (A,11421006,H.O.Menlove,J,PR,163,1308,1967) 3011600400012 ENDBIB 10 0 3011600400013 NOCOMMON 0 0 3011600400014 DATA 5 1 3011600400015 EN DATA DATA-ERR MONIT MONIT-ERR 3011600400016 MEV MB MB MB MB 3011600400017 14.7 63. 4. 114. 4. 3011600400018 ENDDATA 3 0 3011600400019 ENDSUBENT 18 0 3011600499999 ENDENTRY 4 0 3011699999999