ENTRY 30465 20090311 31353046500000001 SUBENT 30465001 20090311 31353046500100001 BIB 10 31 3046500100002 TITLE Measurements of neutron capture cross-section of 3046500100003 232-Th by activation method 3046500100004 AUTHOR (H.M.Jain,R.P.Anand,M.L.Jhingan,R.N.Jindal, 3046500100005 V.C.Deniz,M.K.Mehta) 3046500100006 INSTITUTE (3INDTRM) 3046500100007 EXP-YEAR (1978) 3046500100008 REFERENCE (C,78HARWELL,,1108,197809) Full information. 3046500100009 (P,BARC-990,22,197809) Measured in neutron energy range3046500100010 of 400-600 keV. No data given 3046500100011 (P,INDC(SEC)-61,100,197710) No data given 3046500100012 (P,BARC-897,16,1977) No data given 3046500100013 (P,BARC-897,54,1977) No data given. 3046500100014 (C,76BOMBAY,,542,197603) Experimental details given. 3046500100015 No data given 3046500100016 (P,BARC-843,30,1975) Identical to BARC-897, 1977, p. 163046500100017 (P,BARC-831,13,1975) Identical to BARC-897, 1977, p. 543046500100018 FACILITY (VDG,3INDTRM) 3046500100019 Van-de-Graff using a liquid nitrogen cooled lithium 3046500100020 metal target. 3046500100021 METHOD (ACTIV) Activation method. 3046500100022 DETECTOR (GELI) 27 cm3 high resolution detector and gamma 3046500100023 counting (resolution not given). Energy calibration 3046500100024 was performed with IAEA standard sources. 3046500100025 STATUS (PRELM) 3046500100026 .Data taken from the presentation to 1978 Harwell. 3046500100027 (SPSDD,30781001) 3046500100028 For improved measurement by same authors. 3046500100029 See exfor-30781 3046500100030 HISTORY (19790129C) CS. 3046500100031 (19880415U) TMK reference added. 3046500100032 (20090310A) SD:Updated to new date formats,lower case. 3046500100033 ENDBIB 31 0 3046500100034 NOCOMMON 0 0 3046500100035 ENDSUBENT 34 0 3046500199999 SUBENT 30465002 20090311 31353046500200001 BIB 5 18 3046500200002 REACTION (90-TH-232(N,G)90-TH-233,,SIG) 3046500200003 DECAY-DATA (90-TH-233,22.3MIN,B-,,,DG,459.,0.01, 3046500200004 DG,670.,0.004) 3046500200005 for 90-Th-233 was measured by the author. 3046500200006 The error related to this measurement is 0.5 min. The 3046500200007 abundances were taken from literature,but not mentioned3046500200008 by author. 3046500200009 MONITOR (79-AU-197(N,G)79-AU-198,,SIG) No monitor reference 3046500200010 is given. 3046500200011 DECAY-MON (79-AU-198-G,,B-,,,DG,412.,0.9553) The abundance was 3046500200012 also taken from literature,but not mentioned by author.3046500200013 ERR-ANALYS (ERR-T) Uncertainty includes: 3046500200014 (ERR-1) Efficiency - 5%. 3046500200015 (ERR-2) gold cross sections - 3% 3046500200016 (ERR-3) flux variation - 7% and 3046500200017 Photopeak area - 2% for 412 keV 3046500200018 3% for 459 keV 3046500200019 6% for 670 keV 3046500200020 ENDBIB 18 0 3046500200021 COMMON 5 3 3046500200022 EN-ERR ERR-1 ERR-2 ERR-3 ERR-HL 3046500200023 KEV PER-CENT PER-CENT PER-CENT MIN 3046500200024 20. 5.0 3.0 7.0 0.5 3046500200025 ENDCOMMON 3 0 3046500200026 DATA 4 3 3046500200027 EN DATA ERR-T MONIT 3046500200028 KEV MB MB MB 3046500200029 3.5000E+02 1.4100E+02 1.4000E+01 1.8700E+02 3046500200030 4.6000E+02 1.2300E+02 1.2000E+01 1.5000E+02 3046500200031 6.8000E+02 1.2500E+02 1.2000E+01 1.0800E+02 3046500200032 ENDDATA 5 0 3046500200033 ENDSUBENT 32 0 3046500299999 ENDENTRY 2 0 3046599999999