ENTRY 31459 20221011 3145900000001 SUBENT 31459001 20221011 20231011 3145900100001 BIB 7 14 3145900100002 TITLE Integral neutron cross sections measured around 14 MeV 3145900100003 AUTHOR (I.Garlea, C.Miron-Garlea, H.N.Rosu, G.Fodor, V.Raducu)3145900100004 INSTITUTE (3RUMBUC) 3145900100005 REFERENCE (J,RRP,37,19,1992) 3145900100006 (P,INDC(ROM)-017,22,1986) Some preliminary data. 3145900100007 FACILITY (NGEN,3RUMBUC) Neutron generator 9900-TEXAS type. 3145900100008 INC-SOURCE (D-T) 3145900100009 HISTORY (19960808C) HW.- 3145900100010 (19970424A) HW.- Small corrections under STATUS in 3145900100011 subents 002 - 006. Subents 022-025 added.- 3145900100012 (20030319A) OS. Keyword DECAY-DATA added, converted 3145900100013 to 4-digit year. 3145900100014 (20211001A) VS. Major revision. 3145900100015 (20221011A) VT. Revision in 002-025 3145900100016 ENDBIB 14 0 3145900100017 NOCOMMON 0 0 3145900100018 ENDSUBENT 17 0 3145900199999 SUBENT 31459002 20221011 20231011 3145900200001 BIB 8 23 3145900200002 REACTION (42-MO-92(N,2N)42-MO-91-M,,SIG) 3145900200003 SAMPLE Natural abundance samples. 3145900200004 METHOD (ACTIV) 3145900200005 DETECTOR (GELI) crystal 100 cm3. The crystal resolution (for 3145900200006 1332.5 keV 60Co) was 2.98 keV. 3145900200007 MONITOR (41-NB-93(N,2N)41-NB-92,,SIG) 3145900200008 Neutron flux has also been monitored by three parallel 3145900200009 plate fission chambers set up at 120 degree in the 3145900200010 plane of the tritium target perpendicular to the 3145900200011 deuteron beam. 3145900200012 ERR-ANALYS (ERR-T) Errors associated to the absolute activation 3145900200013 cross sections arise from: 3145900200014 (ERR-S,0.4,1.2) Statistical errors (0.4-1.2%) 3145900200015 (ERR-1,1.5,2.1) Absolute efficiency calibration 3145900200016 (1.5-2.1%) 3145900200017 (ERR-2,0.5,0.9) Background subtraction (0.5-0.9%) 3145900200018 (ERR-3,2.13,2.50) Flux determination (2.13-2.50%) 3145900200019 STATUS (TABLE) Table 3 of Revue Roumaine Physique,7(1992)19 3145900200020 HISTORY (20211005U) VS. Compilation on activation measurements 3145900200021 moved from 001. ERR-ANALYS, STATUS added. 3145900200022 DATA-ERR->ERR-T 3145900200023 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S, DATA: 3145900200024 replaced floating point to fixed point. 3145900200025 ENDBIB 23 0 3145900200026 COMMON 2 3 3145900200027 EN EN-RSL 3145900200028 MEV MEV 3145900200029 14.8 .300 3145900200030 ENDCOMMON 3 0 3145900200031 DATA 3 1 3145900200032 DATA ERR-T MONIT 3145900200033 MB MB MB 3145900200034 164.5 13.7 453.0 3145900200035 ENDDATA 3 0 3145900200036 ENDSUBENT 35 0 3145900299999 SUBENT 31459003 20221011 20231011 3145900300001 BIB 8 23 3145900300002 REACTION (42-MO-92(N,P)41-NB-92-M,,SIG) 3145900300003 SAMPLE Natural abundance samples. 3145900300004 METHOD (ACTIV) 3145900300005 DETECTOR (GELI) crystal 100 cm3. The crystal resolution (for 3145900300006 1332.5 keV 60Co) was 2.98 keV. 3145900300007 MONITOR (41-NB-93(N,2N)41-NB-92,,SIG) 3145900300008 Neutron flux has also been monitored by three parallel 3145900300009 plate fission chambers set up at 120 degree in the 3145900300010 plane of the tritium target perpendicular to the 3145900300011 deuteron beam. 3145900300012 ERR-ANALYS (ERR-T) Errors associated to the absolute activation 3145900300013 cross sections arise from: 3145900300014 (ERR-S,0.4,1.2) Statistical errors (0.4-1.2%) 3145900300015 (ERR-1,1.5,2.1) Absolute efficiency calibration 3145900300016 (1.5-2.1%) 3145900300017 (ERR-2,0.5,0.9) Background subtraction (0.5-0.9%) 3145900300018 (ERR-3,2.13,2.50) Flux determination (2.13-2.50%) 3145900300019 STATUS (TABLE) Table 3 of Revue Roumaine Physique,7(1992)19 3145900300020 HISTORY (20211005U) VS. Compilation on activation measurements 3145900300021 moved from 001. ERR-ANALYS, STATUS added. 3145900300022 DATA-ERR->ERR-T 3145900300023 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S, DATA: 3145900300024 replaced floating point to fixed point. 3145900300025 ENDBIB 23 0 3145900300026 COMMON 2 3 3145900300027 EN EN-RSL 3145900300028 MEV MEV 3145900300029 14.8 .300 3145900300030 ENDCOMMON 3 0 3145900300031 DATA 3 1 3145900300032 DATA ERR-T MONIT 3145900300033 MB MB MB 3145900300034 58.3 3.3 453.0 3145900300035 ENDDATA 3 0 3145900300036 ENDSUBENT 35 0 3145900399999 SUBENT 31459004 20221011 20231011 3145900400001 BIB 8 23 3145900400002 REACTION (42-MO-92(N,A)40-ZR-89-M,,SIG) 3145900400003 SAMPLE Natural abundance samples. 3145900400004 METHOD (ACTIV) 3145900400005 DETECTOR (GELI) crystal 100 cm3. The crystal resolution (for 3145900400006 1332.5 keV 60Co) was 2.98 keV. 3145900400007 MONITOR (41-NB-93(N,2N)41-NB-92,,SIG) 3145900400008 Neutron flux has also been monitored by three parallel 3145900400009 plate fission chambers set up at 120 degree in the 3145900400010 plane of the tritium target perpendicular to the 3145900400011 deuteron beam. 3145900400012 ERR-ANALYS (ERR-T) Errors associated to the absolute activation 3145900400013 cross sections arise from: 3145900400014 (ERR-S,0.4,1.2) Statistical errors (0.4-1.2%) 3145900400015 (ERR-1,1.5,2.1) Absolute efficiency calibration 3145900400016 (1.5-2.1%) 3145900400017 (ERR-2,0.5,0.9) Background subtraction (0.5-0.9%) 3145900400018 (ERR-3,2.13,2.50) Flux determination (2.13-2.50%) 3145900400019 STATUS (TABLE) Table 3 of Revue Roumaine Physique,7(1992)19 3145900400020 HISTORY (20211005U) VS. Compilation on activation measurements 3145900400021 moved from 001. ERR-ANALYS, STATUS added. 3145900400022 DATA-ERR->ERR-T 3145900400023 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S, DATA: 3145900400024 replaced floating point to fixed point. 3145900400025 ENDBIB 23 0 3145900400026 COMMON 2 3 3145900400027 EN EN-RSL 3145900400028 MEV MEV 3145900400029 14.8 .300 3145900400030 ENDCOMMON 3 0 3145900400031 DATA 3 1 3145900400032 DATA ERR-T MONIT 3145900400033 MB MB MB 3145900400034 5.15 0.55 453.0 3145900400035 ENDDATA 3 0 3145900400036 ENDSUBENT 35 0 3145900499999 SUBENT 31459005 20221011 20231011 3145900500001 BIB 8 23 3145900500002 REACTION (42-MO-92(N,A)40-ZR-89-G,,SIG) 3145900500003 SAMPLE Natural abundance samples. 3145900500004 METHOD (ACTIV) 3145900500005 DETECTOR (GELI) crystal 100 cm3. The crystal resolution (for 3145900500006 1332.5 keV 60Co) was 2.98 keV. 3145900500007 MONITOR (41-NB-93(N,2N)41-NB-92,,SIG) 3145900500008 Neutron flux has also been monitored by three parallel 3145900500009 plate fission chambers set up at 120 degree in the 3145900500010 plane of the tritium target perpendicular to the 3145900500011 deuteron beam. 3145900500012 ERR-ANALYS (ERR-T) Errors associated to the absolute activation 3145900500013 cross sections arise from: 3145900500014 (ERR-S,0.4,1.2) Statistical errors (0.4-1.2%) 3145900500015 (ERR-1,1.5,2.1) Absolute efficiency calibration 3145900500016 (1.5-2.1%) 3145900500017 (ERR-2,0.5,0.9) Background subtraction (0.5-0.9%) 3145900500018 (ERR-3,2.13,2.50) Flux determination (2.13-2.50%) 3145900500019 STATUS (TABLE) Table 3 of Revue Roumaine Physique,7(1992)19 3145900500020 HISTORY (20211005U) VS. Compilation on activation measurements 3145900500021 moved from 001. ERR-ANALYS, STATUS added. 3145900500022 DATA-ERR->ERR-T 3145900500023 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S, DATA: 3145900500024 replaced floating point to fixed point. 3145900500025 ENDBIB 23 0 3145900500026 COMMON 2 3 3145900500027 EN EN-RSL 3145900500028 MEV MEV 3145900500029 14.8 .300 3145900500030 ENDCOMMON 3 0 3145900500031 DATA 3 1 3145900500032 DATA ERR-T MONIT 3145900500033 MB MB MB 3145900500034 24.9 2.5 453.0 3145900500035 ENDDATA 3 0 3145900500036 ENDSUBENT 35 0 3145900599999 SUBENT 31459006 20221011 20231011 3145900600001 BIB 8 23 3145900600002 REACTION (42-MO-94(N,2N)42-MO-93-M,,SIG) 3145900600003 SAMPLE Natural abundance samples. 3145900600004 METHOD (ACTIV) 3145900600005 DETECTOR (GELI) crystal 100 cm3. The crystal resolution (for 3145900600006 1332.5 keV 60Co) was 2.98 keV. 3145900600007 MONITOR (41-NB-93(N,2N)41-NB-92,,SIG) 3145900600008 Neutron flux has also been monitored by three parallel 3145900600009 plate fission chambers set up at 120 degree in the 3145900600010 plane of the tritium target perpendicular to the 3145900600011 deuteron beam. 3145900600012 ERR-ANALYS (ERR-T) Errors associated to the absolute activation 3145900600013 cross sections arise from: 3145900600014 (ERR-S,0.4,1.2) Statistical errors (0.4-1.2%) 3145900600015 (ERR-1,1.5,2.1) Absolute efficiency calibration 3145900600016 (1.5-2.1%) 3145900600017 (ERR-2,0.5,0.9) Background subtraction (0.5-0.9%) 3145900600018 (ERR-3,2.13,2.50) Flux determination (2.13-2.50%) 3145900600019 STATUS (TABLE) Table 3 of Revue Roumaine Physique,7(1992)19 3145900600020 HISTORY (20211005U) VS. Compilation on activation measurements 3145900600021 moved from 001. ERR-ANALYS, STATUS added. 3145900600022 DATA-ERR->ERR-T 3145900600023 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S, DATA: 3145900600024 replaced floating point to fixed point. 3145900600025 ENDBIB 23 0 3145900600026 COMMON 2 3 3145900600027 EN EN-RSL 3145900600028 MEV MEV 3145900600029 14.8 .300 3145900600030 ENDCOMMON 3 0 3145900600031 DATA 3 1 3145900600032 DATA ERR-T MONIT 3145900600033 MB MB MB 3145900600034 4.64 0.37 453.0 3145900600035 ENDDATA 3 0 3145900600036 ENDSUBENT 35 0 3145900699999 SUBENT 31459007 20221011 20231011 3145900700001 BIB 8 23 3145900700002 REACTION (42-MO-98(N,P)41-NB-98,,SIG) 3145900700003 SAMPLE Natural abundance samples. 3145900700004 METHOD (ACTIV) 3145900700005 DETECTOR (GELI) crystal 100 cm3. The crystal resolution (for 3145900700006 1332.5 keV 60Co) was 2.98 keV. 3145900700007 MONITOR (41-NB-93(N,2N)41-NB-92,,SIG) 3145900700008 Neutron flux has also been monitored by three parallel 3145900700009 plate fission chambers set up at 120 degree in the 3145900700010 plane of the tritium target perpendicular to the 3145900700011 deuteron beam. 3145900700012 ERR-ANALYS (ERR-T) Errors associated to the absolute activation 3145900700013 cross sections arise from: 3145900700014 (ERR-S,0.4,1.2) Statistical errors (0.4-1.2%) 3145900700015 (ERR-1,1.5,2.1) Absolute efficiency calibration 3145900700016 (1.5-2.1%) 3145900700017 (ERR-2,0.5,0.9) Background subtraction (0.5-0.9%) 3145900700018 (ERR-3,2.13,2.50) Flux determination (2.13-2.50%) 3145900700019 STATUS (TABLE) Table 3 of Revue Roumaine Physique,7(1992)19 3145900700020 HISTORY (20211005U) VS. Compilation on activation measurements 3145900700021 moved from 001. ERR-ANALYS, STATUS added. 3145900700022 DATA-ERR->ERR-T 3145900700023 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S, DATA: 3145900700024 replaced floating point to fixed point. 3145900700025 ENDBIB 23 0 3145900700026 COMMON 2 3 3145900700027 EN EN-RSL 3145900700028 MEV MEV 3145900700029 14.8 .300 3145900700030 ENDCOMMON 3 0 3145900700031 DATA 3 1 3145900700032 DATA ERR-T MONIT 3145900700033 MB MB MB 3145900700034 4.9 0.3 453.0 3145900700035 ENDDATA 3 0 3145900700036 ENDSUBENT 35 0 3145900799999 SUBENT 31459008 20221011 20231011 3145900800001 BIB 8 23 3145900800002 REACTION (13-AL-27(N,A)11-NA-24,,SIG) 3145900800003 SAMPLE Natural abundance samples. 3145900800004 METHOD (ACTIV) 3145900800005 DETECTOR (GELI) crystal 100 cm3. The crystal resolution (for 3145900800006 1332.5 keV 60Co) was 2.98 keV. 3145900800007 MONITOR (41-NB-93(N,2N)41-NB-92,,SIG) 3145900800008 Neutron flux has also been monitored by three parallel 3145900800009 plate fission chambers set up at 120 degree in the 3145900800010 plane of the tritium target perpendicular to the 3145900800011 deuteron beam. 3145900800012 ERR-ANALYS (ERR-T) Errors associated to the absolute activation 3145900800013 cross sections arise from: 3145900800014 (ERR-S,0.4,1.2) Statistical errors (0.4-1.2%) 3145900800015 (ERR-1,1.5,2.1) Absolute efficiency calibration 3145900800016 (1.5-2.1%) 3145900800017 (ERR-2,0.5,0.9) Background subtraction (0.5-0.9%) 3145900800018 (ERR-3,2.13,2.50) Flux determination (2.13-2.50%) 3145900800019 STATUS (TABLE) Table 3 of Revue Roumaine Physique,7(1992)19 3145900800020 HISTORY (20211005U) VS. Compilation on activation measurements 3145900800021 moved from 001. ERR-ANALYS, STATUS added. 3145900800022 DATA-ERR->ERR-T 3145900800023 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S, DATA: 3145900800024 replaced floating point to fixed point. 3145900800025 ENDBIB 23 0 3145900800026 COMMON 2 3 3145900800027 EN EN-RSL 3145900800028 MEV MEV 3145900800029 14.758 .300 3145900800030 ENDCOMMON 3 0 3145900800031 DATA 3 1 3145900800032 DATA ERR-T MONIT 3145900800033 MB MB MB 3145900800034 115.4 3.7 453.0 3145900800035 ENDDATA 3 0 3145900800036 ENDSUBENT 35 0 3145900899999 SUBENT 31459009 20221011 20231011 3145900900001 BIB 8 23 3145900900002 REACTION (13-AL-27(N,P)12-MG-27,,SIG) 3145900900003 SAMPLE Natural abundance samples. 3145900900004 METHOD (ACTIV) 3145900900005 DETECTOR (GELI) crystal 100 cm3. The crystal resolution (for 3145900900006 1332.5 keV 60Co) was 2.98 keV. 3145900900007 MONITOR (41-NB-93(N,2N)41-NB-92,,SIG) 3145900900008 Neutron flux has also been monitored by three parallel 3145900900009 plate fission chambers set up at 120 degree in the 3145900900010 plane of the tritium target perpendicular to the 3145900900011 deuteron beam. 3145900900012 ERR-ANALYS (ERR-T) Errors associated to the absolute activation 3145900900013 cross sections arise from: 3145900900014 (ERR-S,0.4,1.2) Statistical errors (0.4-1.2%) 3145900900015 (ERR-1,1.5,2.1) Absolute efficiency calibration 3145900900016 (1.5-2.1%) 3145900900017 (ERR-2,0.5,0.9) Background subtraction (0.5-0.9%) 3145900900018 (ERR-3,2.13,2.50) Flux determination (2.13-2.50%) 3145900900019 STATUS (TABLE) Table 3 of Revue Roumaine Physique,7(1992)19 3145900900020 HISTORY (20211005U) VS. Compilation on activation measurements 3145900900021 moved from 001. ERR-ANALYS, STATUS added. 3145900900022 DATA-ERR->ERR-T 3145900900023 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S, DATA: 3145900900024 replaced floating point to fixed point. 3145900900025 ENDBIB 23 0 3145900900026 COMMON 2 3 3145900900027 EN EN-RSL 3145900900028 MEV MEV 3145900900029 14.8 .300 3145900900030 ENDCOMMON 3 0 3145900900031 DATA 3 1 3145900900032 DATA ERR-T MONIT 3145900900033 MB MB MB 3145900900034 72.5 3.6 453.0 3145900900035 ENDDATA 3 0 3145900900036 ENDSUBENT 35 0 3145900999999 SUBENT 31459010 20221011 20231011 3145901000001 BIB 8 24 3145901000002 REACTION ((22-TI-48(N,P)21-SC-48,,SIG)+ 3145901000003 (22-TI-49(N,X)21-SC-48,,SIG,,RAB)) 3145901000004 SAMPLE Natural abundance samples. 3145901000005 METHOD (ACTIV) 3145901000006 DETECTOR (GELI) crystal 100 cm3. The crystal resolution (for 3145901000007 1332.5 keV 60Co) was 2.98 keV. 3145901000008 MONITOR (41-NB-93(N,2N)41-NB-92,,SIG) 3145901000009 Neutron flux has also been monitored by three parallel 3145901000010 plate fission chambers set up at 120 degree in the 3145901000011 plane of the tritium target perpendicular to the 3145901000012 deuteron beam. 3145901000013 ERR-ANALYS (ERR-T) Errors associated to the absolute activation 3145901000014 cross sections arise from: 3145901000015 (ERR-S,0.4,1.2) Statistical errors (0.4-1.2%) 3145901000016 (ERR-1,1.5,2.1) Absolute efficiency calibration 3145901000017 (1.5-2.1%) 3145901000018 (ERR-2,0.5,0.9) Background subtraction (0.5-0.9%) 3145901000019 (ERR-3,2.13,2.50) Flux determination (2.13-2.50%) 3145901000020 STATUS (TABLE) Table 3 of Revue Roumaine Physique,7(1992)19 3145901000021 HISTORY (20211001A) VS. REACTION corrected c.f. Memo CP-D/0954.3145901000022 Compilation on activation measurements moved from 001.3145901000023 ERR-ANALYS, STATUS added. DATA-ERR->ERR-T 3145901000024 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S, DATA: 3145901000025 replaced floating point to fixed point. 3145901000026 ENDBIB 24 0 3145901000027 COMMON 2 3 3145901000028 EN EN-RSL 3145901000029 MEV MEV 3145901000030 14.8 .300 3145901000031 ENDCOMMON 3 0 3145901000032 DATA 3 1 3145901000033 DATA ERR-T MONIT 3145901000034 MB MB MB 3145901000035 66.8 3.2 453.0 3145901000036 ENDDATA 3 0 3145901000037 ENDSUBENT 36 0 3145901099999 SUBENT 31459011 20221011 20231011 3145901100001 BIB 8 24 3145901100002 REACTION ((26-FE-56(N,P)25-MN-56,,SIG)+ 3145901100003 (26-FE-57(N,X)25-MN-56,,SIG,,RAB)) 3145901100004 SAMPLE Natural abundance samples. 3145901100005 METHOD (ACTIV) 3145901100006 DETECTOR (GELI) crystal 100 cm3. The crystal resolution (for 3145901100007 1332.5 keV 60Co) was 2.98 keV. 3145901100008 MONITOR (41-NB-93(N,2N)41-NB-92,,SIG) 3145901100009 Neutron flux has also been monitored by three parallel 3145901100010 plate fission chambers set up at 120 degree in the 3145901100011 plane of the tritium target perpendicular to the 3145901100012 deuteron beam. 3145901100013 ERR-ANALYS (ERR-T) Errors associated to the absolute activation 3145901100014 cross sections arise from: 3145901100015 (ERR-S,0.4,1.2) Statistical errors (0.4-1.2%) 3145901100016 (ERR-1,1.5,2.1) Absolute efficiency calibration 3145901100017 (1.5-2.1%) 3145901100018 (ERR-2,0.5,0.9) Background subtraction (0.5-0.9%) 3145901100019 (ERR-3,2.13,2.50) Flux determination (2.13-2.50%) 3145901100020 STATUS (TABLE) Table 3 of Revue Roumaine Physique,7(1992)19 3145901100021 HISTORY (20211001A) VS. REACTION corrected c.f. Memo CP-D/0954.3145901100022 Compilation on activation measurements moved from 001.3145901100023 ERR-ANALYS, STATUS added. DATA-ERR->ERR-T 3145901100024 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S, DATA: 3145901100025 replaced floating point to fixed point. 3145901100026 ENDBIB 24 0 3145901100027 COMMON 2 3 3145901100028 EN EN-RSL 3145901100029 MEV MEV 3145901100030 14.8 .300 3145901100031 ENDCOMMON 3 0 3145901100032 DATA 3 1 3145901100033 DATA ERR-T MONIT 3145901100034 MB MB MB 3145901100035 115.2 5.4 453.0 3145901100036 ENDDATA 3 0 3145901100037 ENDSUBENT 36 0 3145901199999 SUBENT 31459012 20221011 20231011 3145901200001 BIB 8 23 3145901200002 REACTION (26-FE-54(N,P)25-MN-54,,SIG) 3145901200003 SAMPLE Natural abundance samples. 3145901200004 METHOD (ACTIV) 3145901200005 DETECTOR (GELI) crystal 100 cm3. The crystal resolution (for 3145901200006 1332.5 keV 60Co) was 2.98 keV. 3145901200007 MONITOR (41-NB-93(N,2N)41-NB-92,,SIG) 3145901200008 Neutron flux has also been monitored by three parallel 3145901200009 plate fission chambers set up at 120 degree in the 3145901200010 plane of the tritium target perpendicular to the 3145901200011 deuteron beam. 3145901200012 ERR-ANALYS (ERR-T) Errors associated to the absolute activation 3145901200013 cross sections arise from: 3145901200014 (ERR-S,0.4,1.2) Statistical errors (0.4-1.2%) 3145901200015 (ERR-1,1.5,2.1) Absolute efficiency calibration 3145901200016 (1.5-2.1%) 3145901200017 (ERR-2,0.5,0.9) Background subtraction (0.5-0.9%) 3145901200018 (ERR-3,2.13,2.50) Flux determination (2.13-2.50%) 3145901200019 STATUS (TABLE) Table 3 of Revue Roumaine Physique,7(1992)19 3145901200020 HISTORY (20211005U) VS. Compilation on activation measurements 3145901200021 moved from 001. ERR-ANALYS, STATUS added. 3145901200022 DATA-ERR->ERR-T 3145901200023 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S, DATA: 3145901200024 replaced floating point to fixed point. 3145901200025 ENDBIB 23 0 3145901200026 COMMON 2 3 3145901200027 EN EN-RSL 3145901200028 MEV MEV 3145901200029 14.8 .300 3145901200030 ENDCOMMON 3 0 3145901200031 DATA 3 1 3145901200032 DATA ERR-T MONIT 3145901200033 MB MB MB 3145901200034 300.3 23.0 453.0 3145901200035 ENDDATA 3 0 3145901200036 ENDSUBENT 35 0 3145901299999 SUBENT 31459013 20221011 20231011 3145901300001 BIB 8 23 3145901300002 REACTION (27-CO-59(N,P)26-FE-59,,SIG) 3145901300003 SAMPLE Natural abundance samples. 3145901300004 METHOD (ACTIV) 3145901300005 DETECTOR (GELI) crystal 100 cm3. The crystal resolution (for 3145901300006 1332.5 keV 60Co) was 2.98 keV. 3145901300007 MONITOR (41-NB-93(N,2N)41-NB-92,,SIG) 3145901300008 Neutron flux has also been monitored by three parallel 3145901300009 plate fission chambers set up at 120 degree in the 3145901300010 plane of the tritium target perpendicular to the 3145901300011 deuteron beam. 3145901300012 ERR-ANALYS (ERR-T) Errors associated to the absolute activation 3145901300013 cross sections arise from: 3145901300014 (ERR-S,0.4,1.2) Statistical errors (0.4-1.2%) 3145901300015 (ERR-1,1.5,2.1) Absolute efficiency calibration 3145901300016 (1.5-2.1%) 3145901300017 (ERR-2,0.5,0.9) Background subtraction (0.5-0.9%) 3145901300018 (ERR-3,2.13,2.50) Flux determination (2.13-2.50%) 3145901300019 STATUS (TABLE) Table 3 of Revue Roumaine Physique,7(1992)19 3145901300020 HISTORY (20211005U) VS. Compilation on activation measurements 3145901300021 moved from 001. ERR-ANALYS, STATUS added. 3145901300022 DATA-ERR->ERR-T replaced. 3145901300023 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S, DATA: 3145901300024 replaced floating point to fixed point. 3145901300025 ENDBIB 23 0 3145901300026 COMMON 2 3 3145901300027 EN EN-RSL 3145901300028 MEV MEV 3145901300029 14.8 .300 3145901300030 ENDCOMMON 3 0 3145901300031 DATA 3 1 3145901300032 DATA ERR-T MONIT 3145901300033 MB MB MB 3145901300034 46.4 3.1 453.0 3145901300035 ENDDATA 3 0 3145901300036 ENDSUBENT 35 0 3145901399999 SUBENT 31459014 20221011 20231011 3145901400001 BIB 8 23 3145901400002 REACTION (27-CO-59(N,2N)27-CO-58,,SIG) 3145901400003 SAMPLE Natural abundance samples. 3145901400004 METHOD (ACTIV) 3145901400005 DETECTOR (GELI) crystal 100 cm3. The crystal resolution (for 3145901400006 1332.5 keV 60Co) was 2.98 keV. 3145901400007 MONITOR (41-NB-93(N,2N)41-NB-92,,SIG) 3145901400008 Neutron flux has also been monitored by three parallel 3145901400009 plate fission chambers set up at 120 degree in the 3145901400010 plane of the tritium target perpendicular to the 3145901400011 deuteron beam. 3145901400012 ERR-ANALYS (ERR-T) Errors associated to the absolute activation 3145901400013 cross sections arise from: 3145901400014 (ERR-S,0.4,1.2) Statistical errors (0.4-1.2%) 3145901400015 (ERR-1,1.5,2.1) Absolute efficiency calibration 3145901400016 (1.5-2.1%) 3145901400017 (ERR-2,0.5,0.9) Background subtraction (0.5-0.9%) 3145901400018 (ERR-3,2.13,2.50) Flux determination (2.13-2.50%) 3145901400019 STATUS (TABLE) Table 3 of Revue Roumaine Physique,7(1992)19 3145901400020 HISTORY (20211005U) VS. Compilation on activation measurements 3145901400021 moved from 001. ERR-ANALYS, STATUS added. 3145901400022 DATA-ERR->ERR-T replaced. 3145901400023 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S, DATA: 3145901400024 replaced floating point to fixed point. 3145901400025 ENDBIB 23 0 3145901400026 COMMON 2 3 3145901400027 EN EN-RSL 3145901400028 MEV MEV 3145901400029 14.8 .300 3145901400030 ENDCOMMON 3 0 3145901400031 DATA 3 1 3145901400032 DATA ERR-T MONIT 3145901400033 MB MB MB 3145901400034 758.0 55. 453.0 3145901400035 ENDDATA 3 0 3145901400036 ENDSUBENT 35 0 3145901499999 SUBENT 31459015 20221011 20231011 3145901500001 BIB 8 23 3145901500002 REACTION (27-CO-59(N,A)25-MN-56,,SIG) 3145901500003 SAMPLE Natural abundance samples. 3145901500004 METHOD (ACTIV) 3145901500005 DETECTOR (GELI) crystal 100 cm3. The crystal resolution (for 3145901500006 1332.5 keV 60Co) was 2.98 keV. 3145901500007 MONITOR (41-NB-93(N,2N)41-NB-92,,SIG) 3145901500008 Neutron flux has also been monitored by three parallel 3145901500009 plate fission chambers set up at 120 degree in the 3145901500010 plane of the tritium target perpendicular to the 3145901500011 deuteron beam. 3145901500012 ERR-ANALYS (ERR-T) Errors associated to the absolute activation 3145901500013 cross sections arise from: 3145901500014 (ERR-S,0.4,1.2) Statistical errors (0.4-1.2%) 3145901500015 (ERR-1,1.5,2.1) Absolute efficiency calibration 3145901500016 (1.5-2.1%) 3145901500017 (ERR-2,0.5,0.9) Background subtraction (0.5-0.9%) 3145901500018 (ERR-3,2.13,2.50) Flux determination (2.13-2.50%) 3145901500019 STATUS (TABLE) Table 3 of Revue Roumaine Physique,7(1992)19 3145901500020 HISTORY (20211005U) VS. Compilation on activation measurements 3145901500021 moved from 001. ERR-ANALYS, STATUS added. 3145901500022 DATA-ERR->ERR-T replaced. 3145901500023 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S, DATA: 3145901500024 replaced floating point to fixed point. 3145901500025 ENDBIB 23 0 3145901500026 COMMON 2 3 3145901500027 EN EN-RSL 3145901500028 MEV MEV 3145901500029 14.8 .300 3145901500030 ENDCOMMON 3 0 3145901500031 DATA 3 1 3145901500032 DATA ERR-T MONIT 3145901500033 MB MB MB 3145901500034 32.1 1.8 453.0 3145901500035 ENDDATA 3 0 3145901500036 ENDSUBENT 35 0 3145901599999 SUBENT 31459016 20221011 20231011 3145901600001 BIB 8 23 3145901600002 REACTION (28-NI-58(N,2N)28-NI-57,,SIG) 3145901600003 SAMPLE Natural abundance samples. 3145901600004 METHOD (ACTIV) 3145901600005 DETECTOR (GELI) crystal 100 cm3. The crystal resolution (for 3145901600006 1332.5 keV 60Co) was 2.98 keV. 3145901600007 MONITOR (41-NB-93(N,2N)41-NB-92,,SIG) 3145901600008 Neutron flux has also been monitored by three parallel 3145901600009 plate fission chambers set up at 120 degree in the 3145901600010 plane of the tritium target perpendicular to the 3145901600011 deuteron beam. 3145901600012 ERR-ANALYS (ERR-T) Errors associated to the absolute activation 3145901600013 cross sections arise from: 3145901600014 (ERR-S,0.4,1.2) Statistical errors (0.4-1.2%) 3145901600015 (ERR-1,1.5,2.1) Absolute efficiency calibration 3145901600016 (1.5-2.1%) 3145901600017 (ERR-2,0.5,0.9) Background subtraction (0.5-0.9%) 3145901600018 (ERR-3,2.13,2.50) Flux determination (2.13-2.50%) 3145901600019 STATUS (TABLE) Table 3 of Revue Roumaine Physique,7(1992)19 3145901600020 HISTORY (20211005U) VS. Compilation on activation measurements 3145901600021 moved from 001. ERR-ANALYS, STATUS added. 3145901600022 DATA-ERR->ERR-T replaced 3145901600023 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S, DATA: 3145901600024 replaced floating point to fixed point. 3145901600025 ENDBIB 23 0 3145901600026 COMMON 2 3 3145901600027 EN EN-RSL 3145901600028 MEV MEV 3145901600029 14.8 .300 3145901600030 ENDCOMMON 3 0 3145901600031 DATA 3 1 3145901600032 DATA ERR-T MONIT 3145901600033 MB MB MB 3145901600034 36.9 1.8 453.0 3145901600035 ENDDATA 3 0 3145901600036 ENDSUBENT 35 0 3145901699999 SUBENT 31459017 20221011 20231011 3145901700001 BIB 8 23 3145901700002 REACTION (28-NI-58(N,P)27-CO-58,,SIG) 3145901700003 SAMPLE Natural abundance samples. 3145901700004 METHOD (ACTIV) 3145901700005 DETECTOR (GELI) crystal 100 cm3. The crystal resolution (for 3145901700006 1332.5 keV 60Co) was 2.98 keV. 3145901700007 MONITOR (41-NB-93(N,2N)41-NB-92,,SIG) 3145901700008 Neutron flux has also been monitored by three parallel 3145901700009 plate fission chambers set up at 120 degree in the 3145901700010 plane of the tritium target perpendicular to the 3145901700011 deuteron beam. 3145901700012 ERR-ANALYS (ERR-T) Errors associated to the absolute activation 3145901700013 cross sections arise from: 3145901700014 (ERR-S,0.4,1.2) Statistical errors (0.4-1.2%) 3145901700015 (ERR-1,1.5,2.1) Absolute efficiency calibration 3145901700016 (1.5-2.1%) 3145901700017 (ERR-2,0.5,0.9) Background subtraction (0.5-0.9%) 3145901700018 (ERR-3,2.13,2.50) Flux determination (2.13-2.50%) 3145901700019 STATUS (TABLE) Table 3 of Revue Roumaine Physique,7(1992)19 3145901700020 HISTORY (20211005U) VS. Compilation on activation measurements 3145901700021 moved from 001. ERR-ANALYS, STATUS added. 3145901700022 DATA-ERR->ERR-T replaced. 3145901700023 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S, DATA: 3145901700024 replaced floating point to fixed point. 3145901700025 ENDBIB 23 0 3145901700026 COMMON 3 3 3145901700027 EN EN-RSL MONIT 3145901700028 MEV MEV MB 3145901700029 14.8 .300 453.0 3145901700030 ENDCOMMON 3 0 3145901700031 DATA 2 1 3145901700032 DATA ERR-T 3145901700033 MB MB 3145901700034 358.9 18.7 3145901700035 ENDDATA 3 0 3145901700036 ENDSUBENT 35 0 3145901799999 SUBENT 31459018 20221011 20231011 3145901800001 BIB 9 24 3145901800002 REACTION (30-ZN-64(N,P)29-CU-64,,SIG) 3145901800003 RAD-DET (29-CU-64,B+) 3145901800004 SAMPLE Natural abundance samples. 3145901800005 METHOD (ACTIV) 3145901800006 DETECTOR (GELI) crystal 100 cm3. The crystal resolution (for 3145901800007 1332.5 keV 60Co) was 2.98 keV. 3145901800008 MONITOR (41-NB-93(N,2N)41-NB-92,,SIG) 3145901800009 Neutron flux has also been monitored by three parallel 3145901800010 plate fission chambers set up at 120 degree in the 3145901800011 plane of the tritium target perpendicular to the 3145901800012 deuteron beam. 3145901800013 ERR-ANALYS (ERR-T) Errors associated to the absolute activation 3145901800014 cross sections arise from: 3145901800015 (ERR-S,0.4,1.2) Statistical errors (0.4-1.2%) 3145901800016 (ERR-1,1.5,2.1) Absolute efficiency calibration 3145901800017 (1.5-2.1%) 3145901800018 (ERR-2,0.5,0.9) Background subtraction (0.5-0.9%) 3145901800019 (ERR-3,2.13,2.50) Flux determination (2.13-2.50%) 3145901800020 STATUS (TABLE) Table 3 of Revue Roumaine Physique,7(1992)19 3145901800021 HISTORY (20211005U) VS. Compilation on activation measurements 3145901800022 moved from 001. ERR-ANALYS, STATUS added. 3145901800023 DATA-ERR->ERR-T replaced. 3145901800024 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S, DATA: 3145901800025 replaced floating point to fixed point. 3145901800026 ENDBIB 24 0 3145901800027 COMMON 2 3 3145901800028 EN EN-RSL 3145901800029 MEV MEV 3145901800030 14.8 .300 3145901800031 ENDCOMMON 3 0 3145901800032 DATA 3 1 3145901800033 DATA ERR-T MONIT 3145901800034 MB MB MB 3145901800035 158.0 13.2 453.0 3145901800036 ENDDATA 3 0 3145901800037 ENDSUBENT 36 0 3145901899999 SUBENT 31459019 20221011 20231011 3145901900001 BIB 8 23 3145901900002 REACTION (41-NB-93(N,A)39-Y-90-M,,SIG) 3145901900003 SAMPLE Natural abundance samples. 3145901900004 METHOD (ACTIV) 3145901900005 DETECTOR (GELI) crystal 100 cm3. The crystal resolution (for 3145901900006 1332.5 keV 60Co) was 2.98 keV. 3145901900007 MONITOR (41-NB-93(N,2N)41-NB-92,,SIG) 3145901900008 Neutron flux has also been monitored by three parallel 3145901900009 plate fission chambers set up at 120 degree in the 3145901900010 plane of the tritium target perpendicular to the 3145901900011 deuteron beam. 3145901900012 ERR-ANALYS (ERR-T) Errors associated to the absolute activation 3145901900013 cross sections arise from: 3145901900014 (ERR-S,0.4,1.2) Statistical errors (0.4-1.2%) 3145901900015 (ERR-1,1.5,2.1) Absolute efficiency calibration 3145901900016 (1.5-2.1%) 3145901900017 (ERR-2,0.5,0.9) Background subtraction (0.5-0.9%) 3145901900018 (ERR-3,2.13,2.50) Flux determination (2.13-2.50%) 3145901900019 STATUS (TABLE) Table 3 of Revue Roumaine Physique,7(1992)19 3145901900020 HISTORY (20211005U) VS. Compilation on activation measurements 3145901900021 moved from 001. ERR-ANALYS, STATUS added. 3145901900022 DATA-ERR->ERR-T replaced. 3145901900023 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S, DATA: 3145901900024 replaced floating point to fixed point. 3145901900025 ENDBIB 23 0 3145901900026 COMMON 2 3 3145901900027 EN EN-RSL 3145901900028 MEV MEV 3145901900029 14.8 .300 3145901900030 ENDCOMMON 3 0 3145901900031 DATA 3 1 3145901900032 DATA ERR-T MONIT 3145901900033 MB MB MB 3145901900034 5.33 0.27 453.0 3145901900035 ENDDATA 3 0 3145901900036 ENDSUBENT 35 0 3145901999999 SUBENT 31459020 20221011 20231011 3145902000001 BIB 8 23 3145902000002 REACTION (49-IN-115(N,INL)49-IN-115-M,,SIG) 3145902000003 SAMPLE Natural abundance samples. 3145902000004 METHOD (ACTIV) 3145902000005 DETECTOR (GELI) crystal 100 cm3. The crystal resolution (for 3145902000006 1332.5 keV 60Co) was 2.98 keV. 3145902000007 MONITOR (41-NB-93(N,2N)41-NB-92,,SIG) 3145902000008 Neutron flux has also been monitored by three parallel 3145902000009 plate fission chambers set up at 120 degree in the 3145902000010 plane of the tritium target perpendicular to the 3145902000011 deuteron beam. 3145902000012 ERR-ANALYS (ERR-T) Errors associated to the absolute activation 3145902000013 cross sections arise from: 3145902000014 (ERR-S,0.4,1.2) Statistical errors (0.4-1.2%) 3145902000015 (ERR-1,1.5,2.1) Absolute efficiency calibration 3145902000016 (1.5-2.1%) 3145902000017 (ERR-2,0.5,0.9) Background subtraction (0.5-0.9%) 3145902000018 (ERR-3,2.13,2.50) Flux determination (2.13-2.50%) 3145902000019 STATUS (TABLE) Table 3 of Revue Roumaine Physique,7(1992)19 3145902000020 HISTORY (20211005U) VS. Compilation on activation measurements 3145902000021 moved from 001. ERR-ANALYS, STATUS added. 3145902000022 DATA-ERR->ERR-T replaced 3145902000023 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S, DATA: 3145902000024 replaced floating point to fixed point. 3145902000025 ENDBIB 23 0 3145902000026 COMMON 2 3 3145902000027 EN EN-RSL 3145902000028 MEV MEV 3145902000029 14.758 .300 3145902000030 ENDCOMMON 3 0 3145902000031 DATA 3 1 3145902000032 DATA ERR-T MONIT 3145902000033 MB MB MB 3145902000034 83.9 3.8 453.0 3145902000035 ENDDATA 3 0 3145902000036 ENDSUBENT 35 0 3145902099999 SUBENT 31459021 20221011 20231011 3145902100001 BIB 8 23 3145902100002 REACTION (79-AU-197(N,2N)79-AU-196,,SIG) 3145902100003 SAMPLE Natural abundance samples. 3145902100004 METHOD (ACTIV) 3145902100005 DETECTOR (GELI) crystal 100 cm3. The crystal resolution (for 3145902100006 1332.5 keV 60Co) was 2.98 keV. 3145902100007 MONITOR (41-NB-93(N,2N)41-NB-92,,SIG) 3145902100008 Neutron flux has also been monitored by three parallel 3145902100009 plate fission chambers set up at 120 degree in the 3145902100010 plane of the tritium target perpendicular to the 3145902100011 deuteron beam. 3145902100012 ERR-ANALYS (ERR-T) Errors associated to the absolute activation 3145902100013 cross sections arise from: 3145902100014 (ERR-S,0.4,1.2) Statistical errors (0.4-1.2%) 3145902100015 (ERR-1,1.5,2.1) Absolute efficiency calibration 3145902100016 (1.5-2.1%) 3145902100017 (ERR-2,0.5,0.9) Background subtraction (0.5-0.9%) 3145902100018 (ERR-3,2.13,2.50) Flux determination (2.13-2.50%) 3145902100019 STATUS (TABLE) Table 3 of Revue Roumaine Physique,7(1992)19 3145902100020 HISTORY (20211005U) VS. Compilation on activation measurements 3145902100021 moved from 001. ERR-ANALYS, STATUS added. 3145902100022 DATA-ERR->ERR-T replaced. 3145902100023 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S, DATA: 3145902100024 replaced floating point to fixed point. 3145902100025 ENDBIB 23 0 3145902100026 COMMON 2 3 3145902100027 EN EN-RSL 3145902100028 MEV MEV 3145902100029 14.758 .300 3145902100030 ENDCOMMON 3 0 3145902100031 DATA 3 1 3145902100032 DATA ERR-T MONIT 3145902100033 MB MB MB 3145902100034 1896. 85. 453.0 3145902100035 ENDDATA 3 0 3145902100036 ENDSUBENT 35 0 3145902199999 SUBENT 31459022 20221011 20231011 3145902200001 BIB 7 22 3145902200002 REACTION (92-U-238(N,F),,SIG) 3145902200003 MONITOR (92-U-235(N,F),,SIG) 3145902200004 DETECTOR (FISCH) 3145902200005 REL-REF (M,30813012,I.Garlea+,J,RRP,29,421,1984) 3145902200006 Fission chamber characteristics. 3145902200007 ERR-ANALYS (ERR-T) Uncertainties associated to the fission 3145902200008 cross sections arise from: 3145902200009 (ERR-S,0.56,1.81) Counting statistics (0.56-1.81%) 3145902200010 (ERR-1) Undetected fission fragments 3145902200011 due to extrapolation to zero (0.4%) 3145902200012 (ERR-2) Undetected fission fragments 3145902200013 due to absorption in deposit (0.35%) 3145902200014 (ERR-3) Fission impurity isotope (0.02%) 3145902200015 (ERR-4,0.97,1.13) Flux level (run-to-run monitor) 3145902200016 (0.97-1.13%) 3145902200017 (ERR-5,1.6,3.5) Deposit mass calibration (1.6-3.5%) 3145902200018 STATUS (TABLE) Table 1 of Revue Roumaine Physique,7(1992)19 3145902200019 HISTORY (20211005U) VS. ERR-ANALYS, STATUS, DETECTOR added. 3145902200020 DATA-ERR->ERR-T 3145902200021 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S and 0.4-1.2-> 3145902200022 0.56-1.81 replaced. STATUS: SPSDD added, DATA: 3145902200023 replaced floating point to fixed point. 3145902200024 ENDBIB 22 0 3145902200025 COMMON 5 3 3145902200026 EN EN-RSL ERR-1 ERR-2 ERR-3 3145902200027 MEV MEV PER-CENT PER-CENT PER-CENT 3145902200028 14.758 .300 0.4 0.35 0.02 3145902200029 ENDCOMMON 3 0 3145902200030 DATA 3 1 3145902200031 DATA ERR-T MONIT 3145902200032 MB MB MB 3145902200033 1190. 44. 2087. 3145902200034 ENDDATA 3 0 3145902200035 ENDSUBENT 34 0 3145902299999 SUBENT 31459023 20221011 20231011 3145902300001 BIB 7 22 3145902300002 REACTION (94-PU-239(N,F),,SIG) 3145902300003 MONITOR (92-U-235(N,F),,SIG) 3145902300004 DETECTOR (FISCH) 3145902300005 REL-REF (M,30813014,I.Garlea+,J,RRP,29,421,1984) 3145902300006 Fission chamber characteristics. 3145902300007 ERR-ANALYS (ERR-T) Uncertainties associated to the fission 3145902300008 cross sections arise from: 3145902300009 (ERR-S,0.56,1.81) Counting statistics (0.56-1.81%) 3145902300010 (ERR-1) Undetected fission fragments 3145902300011 due to extrapolation to zero (0.4%) 3145902300012 (ERR-2) Undetected fission fragments 3145902300013 due to absorption in deposit (0.35%) 3145902300014 (ERR-3) Fission impurity isotope (0.02%) 3145902300015 (ERR-4,0.97,1.13) Flux level (run-to-run monitor) 3145902300016 (0.97-1.13%) 3145902300017 (ERR-5,1.6,3.5) Deposit mass calibration (1.6-3.5%) 3145902300018 STATUS (TABLE) Table 1 of Revue Roumaine Physique,7(1992)19 3145902300019 HISTORY (20211005U) VS. ERR-ANALYS, STATUS, DETECTOR added. 3145902300020 DATA-ERR->ERR-T 3145902300021 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S and 0.4-1.2-> 3145902300022 0.56-1.81 replaced. DATA: replaced floating point to 3145902300023 fixed point. 3145902300024 ENDBIB 22 0 3145902300025 COMMON 5 3 3145902300026 EN EN-RSL ERR-1 ERR-2 ERR-3 3145902300027 MEV MEV PER-CENT PER-CENT PER-CENT 3145902300028 14.758 .300 0.4 0.35 0.02 3145902300029 ENDCOMMON 3 0 3145902300030 DATA 3 1 3145902300031 DATA ERR-T MONIT 3145902300032 MB MB MB 3145902300033 2521. 81. 2087. 3145902300034 ENDDATA 3 0 3145902300035 ENDSUBENT 34 0 3145902399999 SUBENT 31459024 20221011 20231011 3145902400001 BIB 7 22 3145902400002 REACTION (93-NP-237(N,F),,SIG) 3145902400003 MONITOR (92-U-235(N,F),,SIG) 3145902400004 DETECTOR (FISCH) 3145902400005 REL-REF (M,30813013,I.Garlea+,J,RRP,29,421,1984) 3145902400006 Fission chamber characteristics. 3145902400007 ERR-ANALYS (ERR-T) Uncertainties associated to the fission 3145902400008 cross sections arise from: 3145902400009 (ERR-S,0.56,1.81) Counting statistics (0.56-1.81%) 3145902400010 (ERR-1) Undetected fission fragments 3145902400011 due to extrapolation to zero (0.4%) 3145902400012 (ERR-2) Undetected fission fragments 3145902400013 due to absorption in deposit (0.35%) 3145902400014 (ERR-3) Fission impurity isotope (0.02%) 3145902400015 (ERR-4,0.97,1.13) Flux level (run-to-run monitor) 3145902400016 (0.97-1.13%) 3145902400017 (ERR-5,1.6,3.5) Deposit mass calibration (1.6-3.5%) 3145902400018 STATUS (TABLE) Table 1 of Revue Roumaine Physique,7(1992)19 3145902400019 HISTORY (20211005U) VS. ERR-ANALYS, STATUS, DETECTOR added. 3145902400020 DATA-ERR->ERR-T 3145902400021 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S and 0.4-1.2-> 3145902400022 0.56-1.81 replaced. DATA: replaced floating point to 3145902400023 fixed point. 3145902400024 ENDBIB 22 0 3145902400025 COMMON 5 3 3145902400026 EN EN-RSL ERR-1 ERR-2 ERR-3 3145902400027 MEV MEV PER-CENT PER-CENT PER-CENT 3145902400028 14.758 .300 0.4 0.35 0.02 3145902400029 ENDCOMMON 3 0 3145902400030 DATA 3 1 3145902400031 DATA ERR-T MONIT 3145902400032 MB MB MB 3145902400033 2314. 81. 2087. 3145902400034 ENDDATA 3 0 3145902400035 ENDSUBENT 34 0 3145902499999 SUBENT 31459025 20221011 20231011 3145902500001 BIB 7 22 3145902500002 REACTION (90-TH-232(N,F),,SIG) 3145902500003 MONITOR (92-U-235(N,F),,SIG) 3145902500004 DETECTOR (FISCH) 3145902500005 REL-REF (M,30813011,I.Garlea+,J,RRP,29,421,1984) 3145902500006 Fission chamber characteristics. 3145902500007 ERR-ANALYS (ERR-T) Uncertainties associated to the fission 3145902500008 cross sections arise from: 3145902500009 (ERR-S,0.56,1.81) Counting statistics (0.56-1.81%) 3145902500010 (ERR-1) Undetected fission fragments 3145902500011 due to extrapolation to zero (0.4%) 3145902500012 (ERR-2) Undetected fission fragments 3145902500013 due to absorption in deposit (0.35%) 3145902500014 (ERR-3) Fission impurity isotope (0.02%) 3145902500015 (ERR-4,0.97,1.13) Flux level (run-to-run monitor) 3145902500016 (0.97-1.13%) 3145902500017 (ERR-5,1.6,3.5) Deposit mass calibration (1.6-3.5%) 3145902500018 STATUS (TABLE) Table 1 of Revue Roumaine Physique,7(1992)19 3145902500019 HISTORY (20211005U) VS. ERR-ANALYS, STATUS, DETECTOR added. 3145902500020 DATA-ERR->ERR-T 3145902500021 (20221011A) VT. ERR-ANALYS: ERR-1->ERR-S and 0.4-1.2-> 3145902500022 0.56-1.81 replaced. DATA: replaced floating point to 3145902500023 fixed point. 3145902500024 ENDBIB 22 0 3145902500025 COMMON 5 3 3145902500026 EN EN-RSL ERR-1 ERR-2 ERR-3 3145902500027 MEV MEV PER-CENT PER-CENT PER-CENT 3145902500028 14.758 .300 0.4 0.35 0.02 3145902500029 ENDCOMMON 3 0 3145902500030 DATA 3 1 3145902500031 DATA ERR-T MONIT 3145902500032 MB MB MB 3145902500033 392. 22. 2087. 3145902500034 ENDDATA 3 0 3145902500035 ENDSUBENT 34 0 3145902599999 ENDENTRY 25 0 3145999999999