ENTRY 31472 20100923 31463147200000001 SUBENT 31472001 20100923 31463147200100001 BIB 11 18 3147200100002 TITLE Thermal neutron activation cross-section of some 3147200100003 nuclides used in activation measurements. 3147200100004 REFERENCE (J,NKA,8,437,1963) 3147200100005 AUTHOR (E.T.Jozefowicz) 3147200100006 INSTITUTE (3POLIBJ) 3147200100007 FACILITY (REAC,3POLIBJ) 3147200100008 INC-SOURCE (THCOL) Thermal column of EWA reactor. 3147200100009 INC-SPECT Thermal spectrum. 3147200100010 CORRECTION Corrections have been made for activity induced by 3147200100011 higher energy neutrons, local depression of flux, 3147200100012 selfshielding. 3147200100013 METHOD (ACTIV) 3147200100014 STATUS (TABLE) Data are from the text of Nukleonika, vol. 8, 3147200100015 p. 437(1963). 3147200100016 HISTORY (19780508C) 3147200100017 (19970521T) Data from previous entry 70403 recompiled. 3147200100018 (20100219A) SD:Updated to new date formats, cosmetic 3147200100019 changes. SAMPLE were added to all Subents. 3147200100020 ENDBIB 18 0 3147200100021 COMMON 1 3 3147200100022 EN-DUMMY 3147200100023 EV 3147200100024 2.5300E-02 3147200100025 ENDCOMMON 3 0 3147200100026 ENDSUBENT 25 0 3147200199999 SUBENT 31472002 20100923 31463147200200001 BIB 4 6 3147200200002 REACTION 1((53-I-127(N,G)53-I-128,,SIG,,MXW)/ 3147200200003 (11-NA-23(N,G)11-NA-24,,SIG,,MXW)) 3147200200004 2(53-I-127(N,G)53-I-128,,SIG,,MXW) 3147200200005 MONITOR 2(11-NA-23(N,G)11-NA-24,,SIG,,MXW) 3147200200006 MONIT-REF 2(,D.J.Hughes+,R,BNL-325,1958) 3147200200007 SAMPLE Indium foil was 0.0035 mm thick 3147200200008 ENDBIB 6 0 3147200200009 NOCOMMON 0 0 3147200200010 DATA 4 1 3147200200011 DATA 1DATA 2MONIT 2MONIT-ERR 2 3147200200012 NO-DIM B B B 3147200200013 1.0800E+01 5.7300E+00 5.3000E-01 1.0000E-02 3147200200014 ENDDATA 3 0 3147200200015 ENDSUBENT 14 0 3147200299999 SUBENT 31472003 20100923 31463147200300001 BIB 4 6 3147200300002 REACTION 1((53-I-127(N,G)53-I-128,,SIG,,MXW)/ 3147200300003 (25-MN-55(N,G)25-MN-56,,SIG,,MXW)) 3147200300004 2(53-I-127(N,G)53-I-128,,SIG,,MXW) 3147200300005 MONITOR 2(25-MN-55(N,G)25-MN-56,,SIG,,MXW) 3147200300006 MONIT-REF 2(,D.J.Hughes+,R,BNL-325,1960) 3147200300007 SAMPLE Indium foil was 0.0035 mm thick 3147200300008 ENDBIB 6 0 3147200300009 NOCOMMON 0 0 3147200300010 DATA 4 1 3147200300011 DATA 1DATA 2MONIT 2MONIT-ERR 2 3147200300012 NO-DIM B B B 3147200300013 4.4800E-01 5.9600E+00 1.3300E+01 2.0000E-01 3147200300014 ENDDATA 3 0 3147200300015 ENDSUBENT 14 0 3147200399999 SUBENT 31472004 20100923 31463147200400001 BIB 6 10 3147200400002 REACTION 1((49-IN-115(N,G)49-IN-116-M,,SIG,,MXW)/ 3147200400003 (25-MN-55(N,G)25-MN-56,,SIG,,MXW)) 3147200400004 2(49-IN-115(N,G)49-IN-116-M,,SIG,,MXW) 3147200400005 MONITOR 2(25-MN-55(N,G)25-MN-56,,SIG,,MXW) 3147200400006 MONIT-REF 2(,D.J.Hughes+,R,BNL-325,1960) 3147200400007 SAMPLE Indium foil was 0.0035 mm thick 3147200400008 CORRECTION A correction after Westcott has been introduced as 3147200400009 indium does not fulfill 1/V law below cadmium cut-off. 3147200400010 ERR-ANALYS (DATA-ERR) summarized error was estimated as 4% and 3147200400011 includes error in monitor cross section. 3147200400012 ENDBIB 10 0 3147200400013 NOCOMMON 0 0 3147200400014 DATA 5 1 3147200400015 DATA 1DATA 2DATA-ERR 2MONIT 2MONIT-ERR 2 3147200400016 NO-DIM B B B B 3147200400017 1.1590E+01 1.5400E+02 6.0000E+00 1.3300E+01 2.0000E-01 3147200400018 ENDDATA 3 0 3147200400019 ENDSUBENT 18 0 3147200499999 SUBENT 31472005 20100923 31463147200500001 BIB 5 13 3147200500002 REACTION 1((15-P-31(N,G)15-P-32,,SIG,,MXW)/ 3147200500003 (11-NA-23(N,G)11-NA-24,,SIG,,MXW)) 3147200500004 2(15-P-31(N,G)15-P-32,,SIG,,MXW) 3147200500005 MONITOR 2(11-NA-23(N,G)11-NA-24,,SIG,,MXW) 3147200500006 MONIT-REF 2(,D.J.Hughes+,R,BNL-325,1958) 3147200500007 SAMPLE Following compounds were irradiated: NaH2PO2 x H2O, 3147200500008 Na2CO3, NaNO2, (C6H5CH2)2PH, (C6H5CH2)2PO, 3147200500009 and (C4H9O)3PO; all were placed in the polyethylene 3147200500010 capsules 4 mm in diam. 3147200500011 ERR-ANALYS (DATA-ERR) Error includes standard deviation obtained 3147200500012 from the results of activation measurements on 3147200500013 different samples (compounds), error in monitor cross 3147200500014 section and half-live errors. 3147200500015 ENDBIB 13 0 3147200500016 NOCOMMON 0 0 3147200500017 DATA 6 1 3147200500018 DATA 1ERR-T 1DATA 2DATA-ERR 2MONIT 2MONIT-ERR 23147200500019 NO-DIM NO-DIM B B B B 3147200500020 3.2500E-01 8.0000E-03 1.7200E-01 8.0000E-03 5.3000E-01 1.0000E-023147200500021 ENDDATA 3 0 3147200500022 ENDSUBENT 21 0 3147200599999 SUBENT 31472006 20100923 31463147200600001 BIB 3 7 3147200600002 REACTION ((25-MN-55(N,G)25-MN-56,,SIG,,MXW)/ 3147200600003 (11-NA-23(N,G)11-NA-24,,SIG,,MXW)) 3147200600004 SAMPLE Three manganese samples were placed with sodium 3147200600005 carbonate in three polyethylene capsules, one being 3147200600006 used to measure the cadmium ratio 3147200600007 ERR-ANALYS (ERR-S) Error is standard deviation obtained from the 3147200600008 results of three activation measurements. 3147200600009 ENDBIB 7 0 3147200600010 NOCOMMON 0 0 3147200600011 DATA 2 1 3147200600012 DATA ERR-S 3147200600013 NO-DIM NO-DIM 3147200600014 2.5000E+01 2.0000E-01 3147200600015 ENDDATA 3 0 3147200600016 ENDSUBENT 15 0 3147200699999 ENDENTRY 6 0 3147299999999