ENTRY 31596 20160929 31753159600000001 SUBENT 31596001 20160929 31753159600100001 BIB 15 49 3159600100002 TITLE Measurement on the thermal neutron capture cross 3159600100003 section of 180W 3159600100004 AUTHOR (W.G.Kang, Y.D.Kim, J.I.Lee, I.S.Hahn, A.R.Kim, 3159600100005 H.J.Kim) 3159600100006 INSTITUTE (3KORKOR) Department of Physics, Sejong Univ., Seoul 3159600100007 (3KORKOR) Department of Science Education, Ewha 3159600100008 Woman's University, Seoul 3159600100009 (3KORKNU) Physics Department 3159600100010 REFERENCE (J,PR/C,76,067602,2007) 3159600100011 FACILITY (REAC,3KORKAE) HANARO facility 3159600100012 SAMPLE Two identical tungsten foils (99.9% pure) with a 3159600100013 size of 50.1 mm X50.1 mm X 0.138mm (6.644 g) to 3159600100014 measure the Cd ratio at the same time of the 3159600100015 irradiation. 3159600100016 The thickness of the foil was calculated by dividing 3159600100017 the mass of the foil by the area with a density of 3159600100018 19.25 g/cm3. 3159600100019 One foil was sandwiched by two cadmium foils of about 3159600100020 1 mm thickness. 3159600100021 DECAY-DATA (74-W-181,121.2D,DG,136.3,0.000311, 3159600100022 DG,152.3,0.00083) 3159600100023 DECAY-MON (74-W-185-G,75.1D,DG,125.4,0.000192) 3159600100024 (74-W-187,0.988D,DG,551.5,0.0508, 3159600100025 DG,618.4,0.0628, 3159600100026 DG,685.8,0.273, 3159600100027 DG,772.9,0.0412) 3159600100028 INC-SOURCE (THCOL) The thermal neutron flux was previously 3159600100029 measured at this beam line as about 7-8x10**8 3159600100030 neutrons/sec/cm2. 3159600100031 METHOD (GSPEC) 3159600100032 MONITOR ((MONIT1)74-W-186(N,G)74-W-187,,SIG,,MXW) 3159600100033 ((MONIT2)74-W-184(N,G)74-W-185,,SIG,,MXW) 3159600100034 MONIT-REF ((MONIT1)22842002,M.Karadag+,J,ANE,31,1285,2004) 3159600100035 ((MONIT2)31572004,V.Bondarenko+,J,NP/A,762,167,2005) 3159600100036 DETECTOR (HPGE) a low background HPGe detector located at 700 m 3159600100037 deep underground at Yangyang laboratory of Dark Matter3159600100038 Research Center (DMRC) in Korea 3159600100039 ERR-ANALYS (ERR-T) Total error obtained from the following 3159600100040 partial uncertainties: 3159600100041 (ERR-1) Gamma ray detector efficiency (4%) 3159600100042 - Counting statistics 3159600100043 - Gamma ray intensity 3159600100044 HISTORY (20070514C) SD 3159600100045 (20080105A) SD. New ref. was added. Data were corrected3159600100046 (20080430A) SD. REACTION code was corrected according 3159600100047 to author's comments. 3159600100048 (20101216A) On. INSTITUTE corrected, Preprint deleted. 3159600100049 (20160923A) VS. DECAY-DATA corrected. DECAY-MON added. 3159600100050 ERR-ANALYS modified. 3159600100051 ENDBIB 49 0 3159600100052 COMMON 6 3 3159600100053 EN MONIT1 MONIT1-ERR MONIT2 MONIT2-ERR ERR-1 3159600100054 EV B B B B PER-CENT 3159600100055 0.0253 39.5 2.3 1.76 0.09 4. 3159600100056 ENDCOMMON 3 0 3159600100057 ENDSUBENT 56 0 3159600199999 SUBENT 31596002 20080114 31273159600200001 BIB 2 2 3159600200002 REACTION (74-W-180(N,G)74-W-181,,SIG) 3159600200003 STATUS (TABLE) table from Phys.Ref. C 76,067602,2007 3159600200004 ENDBIB 2 0 3159600200005 NOCOMMON 0 0 3159600200006 DATA 2 1 3159600200007 DATA ERR-T 3159600200008 B B 3159600200009 22.6 1.7 3159600200010 ENDDATA 3 0 3159600200011 ENDSUBENT 10 0 3159600299999 ENDENTRY 2 0 3159699999999