ENTRY 31768 20180925 31863176800000001 SUBENT 31768001 20180925 31863176800100001 BIB 10 19 3176800100002 TITLE Thermal neutron radiative cross sections for 6,7Li, 3176800100003 9Be, 10,11B, 12,13C, and 14,15N 3176800100004 AUTHOR (R.B.Firestone, Zs.Revay) 3176800100005 INSTITUTE (1USAUCX,3HUNKFI,2GERMUN) 3176800100006 REFERENCE (J,PR/C,93,054306,2016) 3176800100007 #doi:10.1103/PhysRevC.93.054306 3176800100008 FACILITY (REAC,3HUNKFI) 10-MW Budapest Reactor 3176800100009 INC-SOURCE (REAC) 3176800100010 INC-SPECT Both thermal and cold neutron beams with neutron flux 3176800100011 at the target 5x10**7 n/cm2s and 2.3x10**8 n/cm2s 3176800100012 respectively. 3176800100013 DETECTOR (HPGE,BGO) Compton suppressed by a BGO-scintillator 3176800100014 guard detector. 3176800100015 Target-detector distance 23.5 cm. 3176800100016 Counting efficiency calibrated from 50 keV to 10 MeV 3176800100017 using radioactive sources and (n,gamma) reactions. 3176800100018 METHOD (GSPEC) PGAA - prompt gamma activation analysis 3176800100019 HISTORY (20160610C) VS 3176800100020 (20180925A) On. Major revision in 026. 3176800100021 ENDBIB 19 0 3176800100022 COMMON 1 3 3176800100023 EN 3176800100024 EV 3176800100025 0.0253 3176800100026 ENDCOMMON 3 0 3176800100027 ENDSUBENT 26 0 3176800199999 SUBENT 31768002 20160610 31743176800200001 BIB 8 24 3176800200002 REACTION (7-N-14(N,G)7-N-15,,SPC) 3176800200003 EN-SEC (E,G) 3176800200004 SAMPLE (7-N-14,NAT=0.99632) 98% enriched deuterated 3176800200005 Urea (CH4N2O) target 3176800200006 REL-REF (R,,M.Berglund+,J,PAC,87,397,2011) abundances for the 3176800200007 targets with natural isotopic composition. 3176800200008 ANALYSIS The absolute gamma -ray transition probabilities were 3176800200009 determined by a least-squares fit of the transition 3176800200010 intensities to the decay scheme assuming that the 3176800200011 intensity is balanced feeding/deexciting each 3176800200012 intermediary level and the total primary transition 3176800200013 intensity deexciting the capture state equals the 3176800200014 secondary intensity populating the ground state. 3176800200015 CORRECTION Gamma-ray intensities were corrected for internal 3176800200016 conversion. 3176800200017 ERR-ANALYS (ERR-T) The total uncertainties were determined from 3176800200018 the following partial uncertainties: 3176800200019 (ERR-1,,3.) detector efficiency (accuracy better than 3176800200020 1% from 0.5 to 6 MeV) 3176800200021 - Decay scheme data 3176800200022 - Fitting procedure 3176800200023 STATUS (TABLE) Tbls. I of Phys.Rev.C93(2016)054306 3176800200024 Only gamma's for which production cross section was 3176800200025 determined in this work are compiled. 3176800200026 ENDBIB 24 0 3176800200027 NOCOMMON 0 0 3176800200028 DATA 4 2 3176800200029 E E-ERR DATA ERR-T 3176800200030 KEV KEV PRT/REAC PRT/REAC 3176800200031 1884.85 0.03 0.1832 0.0008 3176800200032 10829.10 0.21 0.1344 0.0021 3176800200033 ENDDATA 4 0 3176800200034 ENDSUBENT 33 0 3176800299999 SUBENT 31768003 20160610 31743176800300001 BIB 9 31 3176800300002 REACTION (7-N-14(N,G)7-N-15,PAR,SIG) 3176800300003 EN-SEC (E,G) 3176800300004 MONITOR (1-H-1(N,G)1-H-2,PAR,SIG) 3176800300005 REL-REF (R,,M.Berglund+,J,PAC,87,397,2011) abundances for the 3176800300006 targets with natural isotopic composition. 3176800300007 MONIT-REF (23296001,R.B.Firestone+,J,PR/C,93,044311,2016) 3176800300008 MISC-COL (MISC) Total radiative thermal neutron cross section 3176800300009 obtained from the gamma-ray cross sections, total 3176800300010 transition probabilities and isotopic abundance in 3176800300011 the target. 3176800300012 SAMPLE (7-N-14,NAT=0.99632) 3176800300013 The following stoichiometric compounds were used 3176800300014 for the Standardization of the 1884.85 keV gamma-ray 3176800300015 cross section 3176800300016 Standard Formula 3176800300017 Pyridine C5H5N 3176800300018 Melamine C3H6N6 3176800300019 Urea CH4N2O 3176800300020 Ammonium sulphate (NH4)2SO4 3176800300021 Ammonium nitrate-1 NH4NO3 3176800300022 Ammonium nitrate-2 NH4NO3 3176800300023 Ammonium nitrate-3 NH4NO3 3176800300024 ERR-ANALYS (ERR-T) The total uncertainties were determined from 3176800300025 the following partial uncertainties: 3176800300026 (ERR-1,,3.) detector efficiency (accuracy better than 3176800300027 1% from 0.5 to 6 MeV) 3176800300028 - standardisation gamma-ray cross section 3176800300029 - Total transition probabilities 3176800300030 - Statistical uncertainties in the peak analysis of 3176800300031 the gamma-ray spectrum 3176800300032 STATUS (TABLE) Tbls. I of Phys.Rev.C93(2016)054306 3176800300033 ENDBIB 31 0 3176800300034 COMMON 3 3 3176800300035 E-NRM MONIT MONIT-ERR 3176800300036 KEV MB MB 3176800300037 2223. 332.5 0.7 3176800300038 ENDCOMMON 3 0 3176800300039 DATA 6 2 3176800300040 E E-ERR DATA ERR-T MISC MISC-ERR 3176800300041 KEV KEV MB MB MB MB 3176800300042 1884.85 0.03 14.57 0.09 79.5 0.7 3176800300043 10829.10 0.21 10.7 0.4 79.6 0.3 3176800300044 ENDDATA 4 0 3176800300045 ENDSUBENT 44 0 3176800399999 SUBENT 31768004 20160616 31743176800400001 BIB 5 13 3176800400002 REACTION (7-N-14(N,G)7-N-15,,SIG) 3176800400003 REL-REF (R,31586002,T.Belgya,J,PR/C,74,024603,2006) 3176800400004 Gamma-ray cross sections used to determine tot. cr.s. 3176800400005 ANALYSIS Weighted average of the total cross sections obtained 3176800400006 from the gamma-ray cross sections. 3176800400007 STATUS (DEP,31768003) Gamma-ray cross sections 3176800400008 (DEP,31586002) Gamma-ray cross sections 3176800400009 (DEP,31768002) Gamma -ray transition probabilities. 3176800400010 (TABLE) Tbl. I of Phys.Rev.C93(2016)054306 3176800400011 ERR-ANALYS (ERR-T) The total uncertainty was determined from 3176800400012 the following partial uncertainties: 3176800400013 (ERR-S) - Statistical uncertainty 3176800400014 (ERR-1) - Calibration uncertainty. 3176800400015 ENDBIB 13 0 3176800400016 NOCOMMON 0 0 3176800400017 DATA 4 1 3176800400018 DATA ERR-T ERR-S ERR-1 3176800400019 MB MB MB MB 3176800400020 80.0 0.4 0.2 0.3 3176800400021 ENDDATA 3 0 3176800400022 ENDSUBENT 21 0 3176800499999 SUBENT 31768005 20160616 31743176800500001 BIB 8 20 3176800500002 REACTION (7-N-15(N,G)7-N-16,,SPC) 3176800500003 FLAG (1.) from 16N beta- decay. 3176800500004 EN-SEC (E,G) 3176800500005 ANALYSIS The absolute gamma -ray transition probabilities were 3176800500006 determined by a least-squares fit of the transition 3176800500007 intensities to the decay scheme assuming that the 3176800500008 intensity is balanced feeding/deexciting each 3176800500009 intermediary level and the total primary transition 3176800500010 intensity deexciting the capture state equals the 3176800500011 secondary intensity populating the ground state. 3176800500012 CORRECTION Gamma-ray intensities were corrected for internal 3176800500013 conversion. 3176800500014 ERR-ANALYS (ERR-T) The total uncertainties were determined from 3176800500015 the following partial uncertainties: 3176800500016 (ERR-1,,3.) detector efficiency (accuracy better than 3176800500017 1% from 0.5 to 6 MeV) 3176800500018 - Decay scheme data 3176800500019 - Fitting procedure 3176800500020 SAMPLE (7-N-15,ENR=0.98) Pyridine (C5H5N) target. 3176800500021 STATUS (TABLE) Tbls. IV of Phys.Rev.C93(2016)054306 3176800500022 ENDBIB 20 0 3176800500023 NOCOMMON 0 0 3176800500024 DATA 4 3 3176800500025 E DATA ERR-T FLAG 3176800500026 KEV PRT/REAC PRT/REAC NO-DIM 3176800500027 289. 0.999970 0.000005 3176800500028 2192. 0.99959 0.006 3176800500029 6129. 0.670 0.06 1. 3176800500030 ENDDATA 5 0 3176800500031 ENDSUBENT 30 0 3176800599999 SUBENT 31768006 20160616 31743176800600001 BIB 10 21 3176800600002 REACTION (7-N-15(N,G)7-N-16,PAR,SIG) 3176800600003 MONITOR (1-H-1(N,G)1-H-2,PAR,SIG) 3176800600004 MONIT-REF (23296001,R.B.Firestone+,J,PR/C,93,044311,2016) 3176800600005 REL-REF (R,,M.Berglund+,J,PAC,87,397,2011) abundances for the 3176800600006 targets with natural isotopic composition. 3176800600007 EN-SEC (E,G) 3176800600008 FLAG (1.) from 16N beta- decay. 3176800600009 MISC-COL (MISC) Total radiative thermal neutron cross section 3176800600010 obtained from the gamma-ray cross sections, total 3176800600011 transition probabilities and isotopic abundance in 3176800600012 the target. 3176800600013 SAMPLE (7-N-15,ENR=0.98) Pyridine (C5H5N) target. 3176800600014 ERR-ANALYS (ERR-T) The total uncertainties were determined from 3176800600015 the following partial uncertainties: 3176800600016 (ERR-1,,3.) detector efficiency (accuracy better than 3176800600017 1% from 0.5 to 6 MeV) 3176800600018 - Standardization gamma-ray cross section 3176800600019 - Total transition probabilities 3176800600020 - Statistical uncertainties in the peak analysis of 3176800600021 the gamma-ray spectrum 3176800600022 STATUS (TABLE) Tbl. IV of Phys.Rev.C93(2016)054306 3176800600023 ENDBIB 21 0 3176800600024 COMMON 3 3 3176800600025 E-NRM MONIT MONIT-ERR 3176800600026 KEV MB MB 3176800600027 2223. 332.5 0.7 3176800600028 ENDCOMMON 3 0 3176800600029 DATA 6 4 3176800600030 E DATA ERR-T MISC MISC-ERR FLAG 3176800600031 KEV MICRO-B MICRO-B MICRO-B MICRO-B NO-DIM 3176800600032 289. 39.9 0.17 39.9 0.17 3176800600033 2192. 37.7 7.5 37.7 7.5 3176800600034 6129. 25.9 4.4 38.6 6.6 1. 3176800600035 6129. 26.4 1.8 39.4 2.7 3176800600036 ENDDATA 6 0 3176800600037 ENDSUBENT 36 0 3176800699999 SUBENT 31768007 20160616 31743176800700001 BIB 4 7 3176800700002 REACTION (7-N-15(N,G)7-N-16,,SIG) 3176800700003 ANALYSIS Weighted average of the total cross sections obtained 3176800700004 from the gamma-ray cross sections. 3176800700005 STATUS (DEP,31768006) Gamma-ray cross sections 3176800700006 (DEP,31768005) Gamma -ray transition probabilities. 3176800700007 (TABLE) Tbls. IV of Phys.Rev.C93(2016)054306 3176800700008 ERR-ANALYS (DATA-ERR) The unc. is nearly entirely statistical. 3176800700009 ENDBIB 7 0 3176800700010 NOCOMMON 0 0 3176800700011 DATA 2 1 3176800700012 DATA DATA-ERR 3176800700013 MICRO-B MICRO-B 3176800700014 39.6 1.4 3176800700015 ENDDATA 3 0 3176800700016 ENDSUBENT 15 0 3176800799999 SUBENT 31768008 20160616 31743176800800001 BIB 10 27 3176800800002 REACTION (6-C-12(N,G)6-C-13,PAR,SIG) 3176800800003 MONITOR ((MONIT1)1-H-1(N,G)1-H-2,PAR,SIG) 3176800800004 ((MONIT2)7-N-14(N,G)7-N-15,PAR,SIG) 3176800800005 EN-SEC (E,G) 3176800800006 MISC-COL (MISC) Total radiative thermal neutron cross section 3176800800007 obtained from the gamma-ray cross sections, total 3176800800008 transition probabilities and isotopic abundance in 3176800800009 the target. 3176800800010 SAMPLE (6-C-12,NAT=0.9893) 3176800800011 The following stoichiometric compounds were used 3176800800012 Standard Formula 3176800800013 FLAG (1.) Polyethylene (C2H4)n 3176800800014 (2.) Melamine C3H6N6 3176800800015 (3.) Urea CH4N2O 3176800800016 (4.) Pyridine C5H5N 3176800800017 REL-REF (R,,M.Berglund+,J,PAC,87,397,2011) abundances for the 3176800800018 targets with natural isotopic composition. 3176800800019 MONIT-REF (23296001,R.B.Firestone+,J,PR/C,93,044311,2016)(MONIT1)3176800800020 ERR-ANALYS (ERR-T) The total uncertainties were determined from 3176800800021 the following partial uncertainties: 3176800800022 (ERR-1,,3.) detector efficiency (accuracy better than 3176800800023 1% from 0.5 to 6 MeV) 3176800800024 - Standardization gamma-ray cross section 3176800800025 - Total transition probabilities 3176800800026 - Statistical uncertainties in the peak analysis of 3176800800027 the gamma-ray spectrum 3176800800028 STATUS (TABLE) Tbls. V and VI of Phys.Rev.C93(2016)054306 3176800800029 ENDBIB 27 0 3176800800030 NOCOMMON 0 0 3176800800031 DATA 12 5 3176800800032 E DATA ERR-T FLAG MISC MISC-ERR 3176800800033 E-NRM1 MONIT1 MONIT1-ERR E-NRM2 MONIT2 MONIT2-ERR 3176800800034 KEV MB MB NO-DIM MB MB 3176800800035 KEV MB MB KEV MB MB 3176800800036 4945.30 2.67 0.07 1. 3.93 0.10 3176800800037 2223. 332.5 0.7 3176800800038 4945.30 2.64 0.04 2. 3.90 0.06 3176800800039 2223. 332.5 0.7 3176800800040 4945.30 2.73 0.10 3. 4.03 0.14 3176800800041 1885. 79.5 0.7 3176800800042 4945.30 2.604 0.023 4. 3.84 0.03 3176800800043 2223. 332.5 0.7 3176800800044 4945.30 2.621 0.022 4. 3.87 0.03 3176800800045 1885. 79.5 0.7 3176800800046 ENDDATA 14 0 3176800800047 ENDSUBENT 46 0 3176800899999 SUBENT 31768009 20160616 31743176800900001 BIB 3 7 3176800900002 REACTION (6-C-12(N,G)6-C-13,,SIG) 3176800900003 STATUS (DEP,31768006) 4945.30-keV Gamma-ray cross sections 3176800900004 (TABLE) Tbls. VI of Phys.Rev.C93(2016)054306 3176800900005 ERR-ANALYS (ERR-T) The total uncertainty was determined from 3176800900006 the following partial uncertainties: 3176800900007 (ERR-S) - Statistical uncertainty 3176800900008 (ERR-1) - Standardization 3176800900009 ENDBIB 7 0 3176800900010 NOCOMMON 0 0 3176800900011 DATA 4 1 3176800900012 DATA ERR-T ERR-S ERR-1 3176800900013 MB MB MB MB 3176800900014 3.87 0.03 0.03 0.01 3176800900015 ENDDATA 3 0 3176800900016 ENDSUBENT 15 0 3176800999999 SUBENT 31768010 20160616 31743176801000001 BIB 11 24 3176801000002 REACTION (6-C-13(N,G)6-C-14,PAR,SIG) 3176801000003 ASSUMED (ASSUM,6-C-13(N,G)6-C-14,,SPC) 3176801000004 EN-SEC (E,G) 3176801000005 MONITOR (1-H-1(N,G)1-H-2,PAR,SIG) 3176801000006 MISC-COL (MISC) Total radiative thermal neutron cross section 3176801000007 obtained from the gamma-ray cross sections, total 3176801000008 transition probabilities and isotopic abundance in 3176801000009 the target. 3176801000010 SAMPLE (6-C-13,NAT=0.995) Urea target CH4N2O 3176801000011 FLAG (1.) Irradiation 1 3176801000012 (2.) Irradiation 2 3176801000013 (3.) Irradiation 3 3176801000014 REL-REF (R,,M.Berglund+,J,PAC,87,397,2011) abundances for the 3176801000015 targets with natural isotopic composition. 3176801000016 MONIT-REF (23296001,R.B.Firestone+,J,PR/C,93,044311,2016)(MONIT1)3176801000017 ERR-ANALYS (ERR-T) The total uncertainties were determined from 3176801000018 the following partial uncertainties: 3176801000019 (ERR-1,,3.) detector efficiency (accuracy better than 3176801000020 1% from 0.5 to 6 MeV) 3176801000021 - Standardization gamma-ray cross section 3176801000022 - Total transition probabilities 3176801000023 - Statistical uncertainties in the peak analysis of 3176801000024 the gamma-ray spectrum 3176801000025 STATUS (TABLE) Tbl. IX of Phys.Rev.C93(2016)054306 3176801000026 ENDBIB 24 0 3176801000027 COMMON 3 3 3176801000028 E-NRM MONIT MONIT-ERR 3176801000029 KEV MB MB 3176801000030 2223. 332.5 0.7 3176801000031 ENDCOMMON 3 0 3176801000032 DATA 9 6 3176801000033 E E-ERR DATA ERR-T ASSUM ASSUM-ERR 3176801000034 FLAG MISC MISC-ERR 3176801000035 KEV KEV MB MB PRT/REAC PRT/REAC 3176801000036 NO-DIM MB MB 3176801000037 6092.46 0.10 0.207 0.006 0.142 0.004 3176801000038 1. 1.45 0.04 3176801000039 6092.46 0.10 0.187 0.005 0.142 0.004 3176801000040 2. 3176801000041 6092.46 0.10 0.225 0.016 0.142 0.004 3176801000042 3. 1.59 0.11 3176801000043 8174.04 0.10 1.300 0.024 0.855 0.005 3176801000044 1. 1.52 0.03 3176801000045 8174.04 0.10 1.275 0.021 0.855 0.005 3176801000046 2. 1.491 0.025 3176801000047 8174.04 0.10 1.27 0.04 0.855 0.005 3176801000048 3. 1.48 0.04 3176801000049 ENDDATA 16 0 3176801000050 ENDSUBENT 49 0 3176801099999 SUBENT 31768011 20160616 31743176801100001 BIB 4 9 3176801100002 REACTION (6-C-13(N,G)6-C-14,,SIG) 3176801100003 ANALYSIS Weighted average of the total cross sections obtained 3176801100004 from the gamma-ray cross sections. 3176801100005 STATUS (DEP,31768008) Gamma-ray cross sections 3176801100006 (TABLE) Tbls. IX and X of Phys.Rev.C93(2016)054306 3176801100007 ERR-ANALYS (ERR-T) The total uncertainty was determined from 3176801100008 the following partial uncertainties: 3176801100009 (ERR-S) - Statistical uncertainty 3176801100010 (ERR-1) - Standardization 3176801100011 ENDBIB 9 0 3176801100012 NOCOMMON 0 0 3176801100013 DATA 4 1 3176801100014 DATA ERR-T ERR-S ERR-1 3176801100015 MB MB MB MB 3176801100016 1.496 0.018 0.018 0.003 3176801100017 ENDDATA 3 0 3176801100018 ENDSUBENT 17 0 3176801199999 SUBENT 31768012 20160616 31743176801200001 BIB 7 19 3176801200002 REACTION (5-B-10(N,G)5-B-11,,SPC) 3176801200003 EN-SEC (E,G) 3176801200004 SAMPLE (5-B-10,NAT=0.199) 3176801200005 ANALYSIS The absolute gamma -ray transition probabilities were 3176801200006 determined by a least-squares fit of the transition 3176801200007 intensities to the decay scheme assuming that the 3176801200008 intensity is balanced feeding/deexciting each 3176801200009 intermediary level and the total primary transition 3176801200010 intensity deexciting the capture state equals the 3176801200011 secondary intensity populating the ground state. 3176801200012 CORRECTION Gamma-ray intensities were corrected for internal 3176801200013 conversion. 3176801200014 ERR-ANALYS (ERR-T) The total uncertainties were determined from 3176801200015 the following partial uncertainties: 3176801200016 (ERR-1,,3.) detector efficiency (accuracy better than 3176801200017 1% from 0.5 to 6 MeV) 3176801200018 - Decay scheme data 3176801200019 - Fitting procedure 3176801200020 STATUS (TABLE) Tbl. XI of Phys.Rev.C93(2016)054306 3176801200021 ENDBIB 19 0 3176801200022 NOCOMMON 0 0 3176801200023 DATA 4 9 3176801200024 E E-ERR DATA ERR-T 3176801200025 KEV KEV PRT/REAC PRT/REAC 3176801200026 2296.42 0.09 0.092 0.005 3176801200027 2533.54 0.07 0.138 0.008 3176801200028 4444.07 0.09 0.630 0.010 3176801200029 4474.5 0.3 0.0079 0.0008 3176801200030 4711.21 0.08 0.280 0.007 3176801200031 6739.11 0.03 0.189 0.007 3176801200032 7006.72 0.09 0.535 0.010 3176801200033 8916.22 0.24 0.130 0.004 3176801200034 11447.28 0.05 0.0444 0.0025 3176801200035 ENDDATA 11 0 3176801200036 ENDSUBENT 35 0 3176801299999 SUBENT 31768013 20160616 31743176801300001 BIB 9 24 3176801300002 REACTION (5-B-10(N,G)5-B-11,PAR,SIG) 3176801300003 MONITOR ((MONIT1)1-H-1(N,G)1-H-2,PAR,SIG) 3176801300004 ((MONIT2)7-N-14(N,G)7-N-15,PAR,SIG) 3176801300005 EN-SEC (E,G) 3176801300006 MISC-COL (MISC) Total radiative thermal neutron cross section 3176801300007 obtained from the gamma-ray cross sections, total 3176801300008 transition probabilities and isotopic abundance in 3176801300009 the target. 3176801300010 SAMPLE (5-B-10,NAT=0.199) H3BO3 and B4N targets 3176801300011 Transition gamma-ray cross sections were normalised 3176801300012 to hydrogen and nitrogen gamma- ray cross 3176801300013 sections respectively. 3176801300014 REL-REF (R,,M.Berglund+,J,PAC,87,397,2011) abundances for the 3176801300015 targets with natural isotopic composition. 3176801300016 MONIT-REF (23296001,R.B.Firestone+,J,PR/C,93,044311,2016)(MONIT1)3176801300017 ERR-ANALYS (ERR-T) The total uncertainties were determined from 3176801300018 the following partial uncertainties: 3176801300019 (ERR-1,,3.) detector efficiency (accuracy better than 3176801300020 1% from 0.5 to 6 MeV) 3176801300021 - Standardization gamma-ray cross section 3176801300022 - Total transition probabilities 3176801300023 - Statistical uncertainties in the peak analysis of 3176801300024 the gamma-ray spectrum 3176801300025 STATUS (TABLE) Tbl. XII of Phys.Rev.C93(2016)054306 3176801300026 ENDBIB 24 0 3176801300027 COMMON 6 3 3176801300028 E-NRM1 MONIT1 MONIT1-ERR E-NRM2 MONIT2 MONIT2-ERR 3176801300029 KEV MB MB KEV MB MB 3176801300030 2223. 332.5 0.7 1885. 79.5 0.7 3176801300031 ENDCOMMON 3 0 3176801300032 DATA 6 9 3176801300033 E E-ERR DATA ERR-T MISC MISC-ERR 3176801300034 KEV KEV MB MB MB MB 3176801300035 2296.42 0.09 36.4 2.3 395. 25. 3176801300036 2533.54 0.07 56.3 2.4 408. 17. 3176801300037 4444.07 0.09 256. 8. 403. 12. 3176801300038 4474.5 0.3 2.9 0.4 372. 51. 3176801300039 4711.21 0.08 106. 4. 380. 15. 3176801300040 6739.11 0.03 75. 4. 396. 22. 3176801300041 7006.72 0.09 210. 9. 392. 17. 3176801300042 8916.22 0.24 47. 3. 365. 23. 3176801300043 11447.28 0.05 17.9 1.6 404. 35. 3176801300044 ENDDATA 11 0 3176801300045 ENDSUBENT 44 0 3176801399999 SUBENT 31768014 20160617 31743176801400001 BIB 4 11 3176801400002 REACTION (5-B-10(N,G)5-B-11,,SIG) 3176801400003 ANALYSIS Weighted average of the total cross sections obtained 3176801400004 from the gamma-ray cross sections. 3176801400005 STATUS (DEP,31768013) Gamma-ray cross sections. 3176801400006 (DEP,31768012) Gamma -ray transition probabilities. 3176801400007 (TABLE) Tbl. XII of Phys.Rev.C93(2016)054306 3176801400008 ERR-ANALYS (ERR-T) The total uncertainty was determined from 3176801400009 the following partial uncertainties: 3176801400010 (ERR-S) - Statistical uncertainty 3176801400011 (ERR-1) - calibration uncertainties. 3176801400012 (ERR-2) - uncertainty in the 10B abundance 3176801400013 ENDBIB 11 0 3176801400014 NOCOMMON 0 0 3176801400015 DATA 5 1 3176801400016 DATA ERR-T ERR-S ERR-1 ERR-2 3176801400017 MB MB MB MB MB 3176801400018 394. 15. 6. 0.8 14. 3176801400019 ENDDATA 3 0 3176801400020 ENDSUBENT 19 0 3176801499999 SUBENT 31768015 20160617 31743176801500001 BIB 7 19 3176801500002 REACTION (5-B-11(N,G)5-B-12,,SPC) 3176801500003 SAMPLE (5-B-11,NAT=0.801) natural H3BO3 3176801500004 EN-SEC (E,G) 3176801500005 ANALYSIS The absolute gamma -ray transition probabilities were 3176801500006 determined by a least-squares fit of the transition 3176801500007 intensities to the decay scheme assuming that the 3176801500008 intensity is balanced feeding/deexciting each 3176801500009 intermediary level and the total primary transition 3176801500010 intensity deexciting the capture state equals the 3176801500011 secondary intensity populating the ground state. 3176801500012 CORRECTION Gamma-ray intensities were corrected for internal 3176801500013 conversion. 3176801500014 ERR-ANALYS (ERR-T) The total uncertainties were determined from 3176801500015 the following partial uncertainties: 3176801500016 (ERR-1,,3.) detector efficiency (accuracy better than 3176801500017 1% from 0.5 to 6 MeV) 3176801500018 - Decay scheme data 3176801500019 - Fitting procedure 3176801500020 STATUS (TABLE) Tbl. VIII of Phys.Rev.C93(2016)054306 3176801500021 ENDBIB 19 0 3176801500022 NOCOMMON 0 0 3176801500023 DATA 4 3 3176801500024 E E-ERR DATA ERR-T 3176801500025 KEV KEV PRT/REAC PRT/REAC 3176801500026 953.1 0.6 0.292 0.005 3176801500027 2415.57 0.12 0.292 0.005 3176801500028 3368.36 0.17 0.707 0.005 3176801500029 ENDDATA 5 0 3176801500030 ENDSUBENT 29 0 3176801599999 SUBENT 31768016 20160617 31743176801600001 BIB 8 19 3176801600002 REACTION (5-B-11(N,G)5-B-12,PAR,SIG) 3176801600003 MONITOR (1-H-1(N,G)1-H-2,PAR,SIG) 3176801600004 SAMPLE (5-B-11,NAT=0.801) natural H3BO3 3176801600005 REL-REF (R,,M.Berglund+,J,PAC,87,397,2011) abundances for the 3176801600006 targets with natural isotopic composition. 3176801600007 EN-SEC (E,G) 3176801600008 MISC-COL (MISC) Total radiative thermal neutron cross section 3176801600009 obtained from the gamma-ray cross sections, total 3176801600010 transition probabilities and isotopic abundance in 3176801600011 the target. 3176801600012 ERR-ANALYS (ERR-T) The total uncertainties were determined from 3176801600013 the following partial uncertainties: 3176801600014 (ERR-1,,3.) detector efficiency (accuracy better than 3176801600015 1% from 0.5 to 6 MeV) 3176801600016 - Standardization gamma-ray cross section 3176801600017 - Total transition probabilities 3176801600018 - Statistical uncertainties in the peak analysis of 3176801600019 the gamma-ray spectrum 3176801600020 STATUS (TABLE) Tbl. VIII of Phys.Rev.C93(2016)054306 3176801600021 ENDBIB 19 0 3176801600022 COMMON 3 3 3176801600023 E-NRM MONIT MONIT-ERR 3176801600024 KEV MB MB 3176801600025 2223. 332.5 0.7 3176801600026 ENDCOMMON 3 0 3176801600027 DATA 6 3 3176801600028 E E-ERR DATA ERR-T MISC MISC-ERR 3176801600029 KEV KEV MB MB MB MB 3176801600030 953.1 0.6 2.66 0.19 9.11 0.16 3176801600031 2415.57 0.12 2.65 0.8 9.06 0.16 3176801600032 3368.36 0.17 6.43 0.8 9.09 0.06 3176801600033 ENDDATA 5 0 3176801600034 ENDSUBENT 33 0 3176801699999 SUBENT 31768017 20160617 31743176801700001 BIB 4 11 3176801700002 REACTION (5-B-11(N,G)5-B-12,,SIG) 3176801700003 ANALYSIS Weighted average of the total cross sections obtained 3176801700004 from the gamma-ray cross sections. 3176801700005 STATUS (DEP,31768016) Gamma-ray cross sections. 3176801700006 (DEP,31768015) Gamma-ray transition probabilities. 3176801700007 (TABLE) Tbls. XIII of Phys.Rev.C93(2016)054306 3176801700008 ERR-ANALYS (ERR-T) The total uncertainty was determined from 3176801700009 the following partial uncertainties: 3176801700010 (ERR-S) - Statistical uncertainty 3176801700011 (ERR-1) - calibration uncertainties. 3176801700012 (ERR-2) - uncertainty in the 11B abundance 3176801700013 ENDBIB 11 0 3176801700014 NOCOMMON 0 0 3176801700015 DATA 5 1 3176801700016 DATA ERR-T ERR-S ERR-1 ERR-2 3176801700017 MB MB MB MB MB 3176801700018 9.09 0.10 0.06 0.02 0.08 3176801700019 ENDDATA 3 0 3176801700020 ENDSUBENT 19 0 3176801799999 SUBENT 31768018 20160617 31743176801800001 BIB 6 20 3176801800002 REACTION (4-BE-9(N,G)4-BE-10,,SPC) 3176801800003 SAMPLE Be(NO3)2 target. 3176801800004 ANALYSIS The absolute gamma -ray transition probabilities were 3176801800005 determined by a least-squares fit of the transition 3176801800006 intensities to the decay scheme assuming that the 3176801800007 intensity is balanced feeding/deexciting each 3176801800008 intermediary level and the total primary transition 3176801800009 intensity deexciting the capture state equals the 3176801800010 secondary intensity populating the ground state. 3176801800011 CORRECTION Gamma-ray intensities were corrected for internal 3176801800012 conversion. 3176801800013 ERR-ANALYS (ERR-T) The total uncertainties were determined from 3176801800014 the following partial uncertainties: 3176801800015 (ERR-1,,3.) detector efficiency (accuracy better than 3176801800016 1% from 0.5 to 6 MeV) 3176801800017 - Decay scheme data 3176801800018 - Fitting procedure 3176801800019 STATUS (TABLE) Tbls. XIV of Phys.Rev.C93(2016)054306 3176801800020 Only gamma's for which production cross section was 3176801800021 determined in this work are compiled. 3176801800022 ENDBIB 20 0 3176801800023 NOCOMMON 0 0 3176801800024 DATA 4 5 3176801800025 E E-ERR DATA ERR-T 3176801800026 KEV KEV PRT/REAC PRT/REAC 3176801800027 853.631 0.011 0.235 0.005 3176801800028 2590.014 0.025 0.218 0.005 3176801800029 3367.48 0.04 0.335 0.005 3176801800030 3443.42 0.04 0.114 0.004 3176801800031 6809.58 0.10 0.647 0.005 3176801800032 ENDDATA 7 0 3176801800033 ENDSUBENT 32 0 3176801899999 SUBENT 31768019 20160617 31743176801900001 BIB 7 18 3176801900002 REACTION (4-BE-9(N,G)4-BE-10,PAR,SIG) 3176801900003 EN-SEC (E,G) 3176801900004 MISC-COL (MISC) Total radiative thermal neutron cross section 3176801900005 obtained from the gamma-ray cross sections, total 3176801900006 transition probabilities and isotopic abundance in 3176801900007 the target. 3176801900008 MONITOR (7-N-14(N,G)7-N-15,PAR,SIG) 3176801900009 SAMPLE Be(NO3)2 target. 3176801900010 ERR-ANALYS (ERR-T) The total uncertainties were determined from 3176801900011 the following partial uncertainties: 3176801900012 (ERR-1,,3.) detector efficiency (accuracy better than 3176801900013 1% from 0.5 to 6 MeV) 3176801900014 - Standardization gamma-ray cross section 3176801900015 - Total transition probabilities 3176801900016 - Statistical uncertainties in the peak analysis of 3176801900017 the gamma-ray spectrum 3176801900018 STATUS (TABLE) Tbl. XIV of Phys.Rev.C93(2016)054306 3176801900019 (DEP,31768018) Gamma-ray transition probabilities. 3176801900020 ENDBIB 18 0 3176801900021 COMMON 3 3 3176801900022 E-NRM MONIT MONIT-ERR 3176801900023 KEV MB MB 3176801900024 1885. 79.5 0.7 3176801900025 ENDCOMMON 3 0 3176801900026 DATA 6 5 3176801900027 E E-ERR DATA ERR-T MISC MISC-ERR 3176801900028 KEV KEV MB MB MB MB 3176801900029 853.631 0.011 1.92 0.05 8.16 0.26 3176801900030 2590.014 0.025 1.82 0.11 8.4 0.6 3176801900031 3367.48 0.04 2.81 0.07 8.40 0.23 3176801900032 3443.42 0.04 0.94 0.4 8.3 0.4 3176801900033 6809.58 0.10 5.31 0.13 8.21 0.21 3176801900034 ENDDATA 7 0 3176801900035 ENDSUBENT 34 0 3176801999999 SUBENT 31768020 20160617 31743176802000001 BIB 4 9 3176802000002 REACTION (4-BE-9(N,G)4-BE-10,,SIG) 3176802000003 ANALYSIS Weighted average of the total cross sections obtained 3176802000004 from the gamma-ray cross sections. 3176802000005 STATUS (DEP,31768019) Gamma-ray cross sections. 3176802000006 (TABLE) Tbls. XIV of Phys.Rev.C93(2016)054306 3176802000007 ERR-ANALYS (ERR-T) The total uncertainty was determined from 3176802000008 the following partial uncertainties: 3176802000009 (ERR-S) - Statistical uncertainty 3176802000010 (ERR-1) - calibration uncertainties. 3176802000011 ENDBIB 9 0 3176802000012 NOCOMMON 0 0 3176802000013 DATA 4 1 3176802000014 DATA ERR-T ERR-S ERR-1 3176802000015 MB MB MB MB 3176802000016 8.27 0.13 0.12 0.03 3176802000017 ENDDATA 3 0 3176802000018 ENDSUBENT 17 0 3176802099999 SUBENT 31768021 20160617 31743176802100001 BIB 7 21 3176802100002 REACTION (3-LI-6(N,G)3-LI-7,,SPC) 3176802100003 EN-SEC (E,G) 3176802100004 SAMPLE (3-LI-6,NAT=0.0759) Li2CO3 target 3176802100005 ANALYSIS The absolute gamma -ray transition probabilities were 3176802100006 determined by a least-squares fit of the transition 3176802100007 intensities to the decay scheme assuming that the 3176802100008 intensity is balanced feeding/deexciting each 3176802100009 intermediary level and the total primary transition 3176802100010 intensity deexciting the capture state equals the 3176802100011 secondary intensity populating the ground state. 3176802100012 CORRECTION Gamma-ray intensities were corrected for internal 3176802100013 conversion. 3176802100014 ERR-ANALYS (ERR-T) The total uncertainties were determined from 3176802100015 the following partial uncertainties: 3176802100016 (ERR-1,,3.) detector efficiency (accuracy better than 3176802100017 1% from 0.5 to 6 MeV) 3176802100018 - Decay scheme data 3176802100019 - Fitting procedure 3176802100020 STATUS (TABLE) Tbl. XVI of Phys.Rev.C93(2016)054306 3176802100021 Only gamma int. for which production cross 3176802100022 section was determined in this work are compiled. 3176802100023 ENDBIB 21 0 3176802100024 NOCOMMON 0 0 3176802100025 DATA 4 1 3176802100026 E E-ERR DATA ERR-T 3176802100027 KEV KEV PRT/REAC PRT/REAC 3176802100028 7246.7 0.3 0.6038 0.0018 3176802100029 ENDDATA 3 0 3176802100030 ENDSUBENT 29 0 3176802199999 SUBENT 31768022 20160617 31743176802200001 BIB 6 14 3176802200002 REACTION (3-LI-6(N,G)3-LI-7,PAR,SIG) 3176802200003 EN-SEC (E,G) 3176802200004 SAMPLE (3-LI-6,NAT=0.0759) Li2CO3 target 3176802200005 MONITOR (6-C-12(N,G)6-C-13,PAR,SIG) 3176802200006 ERR-ANALYS (ERR-T) The total uncertainties were determined from 3176802200007 the following partial uncertainties: 3176802200008 (ERR-1,,3.) detector efficiency (accuracy better than 3176802200009 1% from 0.5 to 6 MeV) 3176802200010 - Standardization gamma-ray cross section 3176802200011 - Total transition probabilities 3176802200012 - Statistical uncertainties in the peak analysis of 3176802200013 the gamma-ray spectrum 3176802200014 STATUS (TABLE) Tbl. XVI of Phys.Rev.C93(2016)054306 3176802200015 (DEP,31768021) Gamma-ray transition probabilitY. 3176802200016 ENDBIB 14 0 3176802200017 COMMON 3 3 3176802200018 E-NRM MONIT MONIT-ERR 3176802200019 KEV MB MB 3176802200020 4945.30 3.87 0.03 3176802200021 ENDCOMMON 3 0 3176802200022 DATA 4 1 3176802200023 E E-ERR DATA ERR-T 3176802200024 KEV KEV MB MB 3176802200025 7246.7 0.3 23.7 0.3 3176802200026 ENDDATA 3 0 3176802200027 ENDSUBENT 26 0 3176802299999 SUBENT 31768023 20160617 31743176802300001 BIB 5 11 3176802300002 REACTION (3-LI-6(N,G)3-LI-7,,SIG) 3176802300003 SAMPLE (3-LI-6,NAT=0.0759) Li2CO3 target 3176802300004 REL-REF (R,,M.Berglund+,J,PAC,87,397,2011) abundances for the 3176802300005 targets with natural isotopic composition. 3176802300006 STATUS (DEP,31768022) Gamma-ray cross section. 3176802300007 (TABLE) Tbl. XVI of Phys.Rev.C93(2016)054306 3176802300008 ERR-ANALYS (ERR-T) The total uncertainty was determined from 3176802300009 the following partial uncertainties: 3176802300010 (ERR-S) - Statistical uncertainty 3176802300011 (ERR-1) - Standardization uncertainties. 3176802300012 (ERR-2) - uncertainty in the 6Li abundance. 3176802300013 ENDBIB 11 0 3176802300014 NOCOMMON 0 0 3176802300015 DATA 5 1 3176802300016 DATA ERR-T ERR-S ERR-1 ERR-2 3176802300017 MB MB MB MB MB 3176802300018 39.3 0.7 0.6 0.2 0.2 3176802300019 ENDDATA 3 0 3176802300020 ENDSUBENT 19 0 3176802399999 SUBENT 31768024 20160617 31743176802400001 BIB 7 20 3176802400002 REACTION (3-LI-7(N,G)3-LI-8,PAR,SIG) 3176802400003 EN-SEC (E,G) 3176802400004 SAMPLE A LiF target enriched to 98% in 7Li 3176802400005 and a natural Li2CO3 target. The data 3176802400006 normalised to fluorine and carbon gamma- ray cross 3176802400007 sections respectively. 3176802400008 MONITOR ((MONIT1)9-F-20(N,G)9-F-21,PAR,SIG) 3176802400009 ((MONIT2)6-C-12(N,G)6-C-13,PAR,SIG) 3176802400010 ERR-ANALYS (ERR-T) The total uncertainties were determined from 3176802400011 the following partial uncertainties: 3176802400012 (ERR-1,,3.) detector efficiency (accuracy better than 3176802400013 1% from 0.5 to 6 MeV) 3176802400014 - Standardization gamma-ray cross section 3176802400015 - Total transition probabilities 3176802400016 - Statistical uncertainties in the peak analysis of 3176802400017 the gamma-ray spectrum 3176802400018 STATUS (TABLE) Tbl. XVI of Phys.Rev.C93(2016)054306 3176802400019 Weighted average data. 3176802400020 MONIT-REF (31582002,L.Szentmiklosi+,J,NIM/A,564,655,2006) 3176802400021 1633 keV 20F(n,g) cross section. 3176802400022 ENDBIB 20 0 3176802400023 COMMON 6 3 3176802400024 E-NRM1 MONIT1 MONIT1-ERR E-NRM2 MONIT2 MONIT2-ERR 3176802400025 KEV MB MB KEV MB MB 3176802400026 1633. 9.32 0.22 4945.30 3.87 0.03 3176802400027 ENDCOMMON 3 0 3176802400028 DATA 4 1 3176802400029 E E-ERR DATA ERR-T 3176802400030 KEV KEV MB MB 3176802400031 2032.300 0.020 39.8 0.3 3176802400032 ENDDATA 3 0 3176802400033 ENDSUBENT 32 0 3176802499999 SUBENT 31768025 20160617 31743176802500001 BIB 3 8 3176802500002 REACTION (3-LI-7(N,G)3-LI-8,,SIG) 3176802500003 STATUS (DEP,31768018) gamma-ray cross section 3176802500004 (TABLE) Tbl. XVI of Phys.Rev.C93(2016)054306 3176802500005 ERR-ANALYS (ERR-T) The total uncertainty was determined from 3176802500006 the following partial uncertainties: 3176802500007 (ERR-S) - Statistical uncertainty 3176802500008 (ERR-1) - Standardization uncertainties. 3176802500009 (ERR-2) - uncertainty in the 7Li abundance. 3176802500010 ENDBIB 8 0 3176802500011 NOCOMMON 0 0 3176802500012 DATA 5 1 3176802500013 DATA ERR-T ERR-S ERR-1 ERR-2 3176802500014 MB MB MB MB MB 3176802500015 44.3 0.5 0.4 0.3 0.2 3176802500016 ENDDATA 3 0 3176802500017 ENDSUBENT 16 0 3176802599999 SUBENT 31768026 20180925 31863176802600001 BIB 7 14 3176802600002 REACTION (5-B-11(N,G)5-B-12,PAR,SIG,DG) 3176802600003 MONITOR (1-H-1(N,G)1-H-2,PAR,SIG) 3176802600004 SAMPLE (5-B-11,NAT=0.801) natural H3BO3 3176802600005 REL-REF (R,,M.Berglund+,J,PAC,87,397,2011) 3176802600006 Natural isotopic abundance 3176802600007 ERR-ANALYS (ERR-T) The total uncertainties were determined from 3176802600008 the following partial uncertainties: 3176802600009 (ERR-1,,3.) detector efficiency (accuracy better than 3176802600010 1% from 0.5 to 6 MeV) 3176802600011 - Standardization gamma-ray cross section 3176802600012 - Statistical uncertainties in the peak analysis of 3176802600013 the gamma-ray spectrum 3176802600014 STATUS (TABLE) Text (054306-9) of Phys.Rev.C93(2016)054306 3176802600015 HISTORY (20180925A) On. REACTION(SF5) revised and E added. 3176802600016 ENDBIB 14 0 3176802600017 COMMON 3 3 3176802600018 E-NRM MONIT MONIT-ERR 3176802600019 KEV MB MB 3176802600020 2223. 332.5 0.7 3176802600021 ENDCOMMON 3 0 3176802600022 DATA 3 2 3176802600023 E DATA ERR-T 3176802600024 KEV MICRO-B MICRO-B 3176802600025 3214.8 74. 16. 3176802600026 4438.0 81. 18. 3176802600027 ENDDATA 4 0 3176802600028 ENDSUBENT 27 0 3176802699999 ENDENTRY 26 0 3176899999999