ENTRY 32582 20100328 31473258200000001 SUBENT 32582001 20100328 31473258200100001 BIB 13 46 3258200100002 TITLE Activation cross section measurement for the 3258200100003 Ho-165(n,gamma)Ho-166m reaction. 3258200100004 INSTITUTE (3CPRSIU) 3258200100005 REFERENCE (J,CNP,17,(1),43,1995) 3258200100006 (W,Wang Chunhao,199304)private communication 3258200100007 AUTHOR (Xia Yijun,Long Xianguan,Luo Xiaobing,Yang Zhihua, 3258200100008 Liu Mantian,Wang Chunhao,Yang Jingfu,He Fuqing, 3258200100009 Peng Xiufeng,Lu Hanlin) 3258200100010 FACILITY (VDG,3CPRSIU) Sichuan University pulsed 2.5 mv Van de 3258200100011 Graaff accelerator 3258200100012 INC-SOURCE (P-LI7,P-T)29-230 keV and 215-1100 keV neutrons were 3258200100013 produced by Li-7(p,n) and T(p,n) reaction respectively 3258200100014 the samples were irradiated simultaneously at 0, 30, 3258200100015 60, 90 and 120 degrees with respect to the incident 3258200100016 proton beam. 3258200100017 SAMPLE 99.9% Pure Ho2O3 powder processed into thin disks. The 3258200100018 diameter is 20 mm. The samples were sandwiched between 3258200100019 two gold foils with thickness 0.1 mm, wrapped in 0.3 3258200100020 mm thick cadmium foils. 3258200100021 METHOD (ACTIV) The induced gamma-ray was detected after 2 3258200100022 months cooling. 3258200100023 DETECTOR (GE-IN)Ortec GEM-30195 HPGe detector.The energy resolu-3258200100024 tion is 2.1 keV for 1332 keV Co-60 peak.The efficiency 3258200100025 was calibrated with Am-241,Cd-109,Co-57,Mn-54,Zn-65, 3258200100026 Eu-152,Co-60,and Na-22 standard gamma sources. 3258200100027 CORRECTION Corrections have been made for neutron scattering 3258200100028 and attenuation. 3258200100029 ERR-ANALYS (ERR-T) Total 20.5%,including: 3258200100030 (ERR-S) counting statistics about 19.6%; 3258200100031 (ERR-1) detector efficiency less than 1.5%; 3258200100032 (ERR-2) correction error about 1.0%; 3258200100033 (ERR-3) standard cross section 3.5%; 3258200100034 (ERR-4) irradiation history less than 2.0%; 3258200100035 (ERR-5) decay scheme 3.5%; 3258200100036 (ERR-6) background 1.0%; 3258200100037 (ERR-7) gamma self absorption in the sample 1.0%; 3258200100038 (ERR-8) sample weighting 0.5%. 3258200100039 STATUS (TABLE)Data taken from the paper offered by the authors3258200100040 HISTORY (19930416C) Compiled by Liu Tingjin,CNDC 3258200100041 (19960502A) HW.- Reference added in sub. 0011. data 3258200100042 corrected in sub. 002 and new data added.- 3258200100043 (20100328A) SD:Updated to new date formats,lower case. 3258200100044 Cosmetic changes and corrections 3258200100045 Author's name corrected: He Fuging => He Fuqing 3258200100046 MONITOR moved to Subent 002 and MONIT data were added 3258200100047 to DATA 3258200100048 ENDBIB 46 0 3258200100049 COMMON 9 6 3258200100050 ERR-S ERR-1 ERR-2 ERR-3 ERR-4 ERR-5 3258200100051 ERR-6 ERR-7 ERR-8 3258200100052 PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT 3258200100053 PER-CENT PER-CENT PER-CENT 3258200100054 19.6 1.5 1. 3.5 2. 3.5 3258200100055 1. 1. 0.5 3258200100056 ENDCOMMON 6 0 3258200100057 ENDSUBENT 56 0 3258200199999 SUBENT 32582002 20100328 31473258200200001 BIB 3 5 3258200200002 REACTION (67-HO-165(N,G)67-HO-166-M,,SIG) 3258200200003 MONITOR (79-AU-197(N,G)79-AU-198,,SIG) 3258200200004 The data were taken from ENDF/B-6. 3258200200005 HISTORY (19960502A) HW.-Data corrected and new data added.- 3258200200006 (20110208A) SD: MONITOR and MONIT data were added 3258200200007 ENDBIB 5 0 3258200200008 NOCOMMON 0 0 3258200200009 DATA 6 3 3258200200010 EN EN-ERR DATA ERR-T MONIT MONIT-ERR 3258200200011 MEV MEV MB MB MB MB 3258200200012 0.203 0.30 37.4 5.6 249.2 7.5 3258200200013 0.676 0.114 12.2 2.4 98.2 3.4 3258200200014 0.974 0.126 10.9 3.4 81.2 2.8 3258200200015 ENDDATA 5 0 3258200200016 ENDSUBENT 15 0 3258200299999 ENDENTRY 2 0 3258299999999