ENTRY 33080 20150107 31683308000000001 SUBENT 33080001 20150107 31683308000100001 BIB 9 19 3308000100002 TITLE Cross sections of the (n,p) reaction on the 78Se and 3308000100003 80Se isotopes measured for 13.73 MeV to 14.77 MeV and 3308000100004 estimated for 10 MeV to 20 MeV neutron energies 3308000100005 AUTHOR (F.M.D.Attar, S.D.Dhole, V.N.Bhoraskar) 3308000100006 INSTITUTE (3INDIND) Fergusson College, Pune 3308000100007 (3INDPOO) 3308000100008 REFERENCE (J,PR/C,90,064609,2014) 3308000100009 FACILITY (CCW,3INDPOO) 14 MeV neutron generator 3308000100010 INC-SOURCE (D-T) Deuterium ion beam (175 keV, ~4 mm in diam., 3308000100011 ~100 uA on target) on an 8 Curie tritium target 3308000100012 DETECTOR (HPGE) To measure gamma-ray activities of the 3308000100013 irradiated samples. 3308000100014 The detection efficiency was measured with a Canberra 3308000100015 make Multi Standard MGS-3 gamma-ray source. 3308000100016 ERR-ANALYS (ERR-1) Detector efficiency (~1.5%) 3308000100017 (ERR-2,,14.) Self absorption of gamma-rays (<14%) 3308000100018 (ERR-3,,1.) Neutron energy distribution (<1%) 3308000100019 (ERR-4,,2.2) Absolute gamma-ray intensity (<2.2%) 3308000100020 HISTORY (20150107C) Compiled by R.Ghosh, S.Badwar, NEHU, INDIA 3308000100021 ENDBIB 19 0 3308000100022 COMMON 1 3 3308000100023 ERR-1 3308000100024 PER-CENT 3308000100025 1.5 3308000100026 ENDCOMMON 3 0 3308000100027 ENDSUBENT 26 0 3308000199999 SUBENT 33080002 20150107 31683308000200001 BIB 9 15 3308000200002 REACTION (34-SE-78(N,P)33-AS-78,,SIG) 3308000200003 SAMPLE (34-SE-78,NAT=0.2377) 3308000200004 Natural SeO2 (purity of 99.99%) powder 3308000200005 (26-FE-56,NAT=0.9175) 3308000200006 Natural Fe (purity of 99.99%) powder 3308000200007 DECAY-DATA (33-AS-78,90.7MIN,DG,614.,0.54) 3308000200008 MONITOR (26-FE-56(N,P)25-MN-56,,SIG) 3308000200009 DECAY-MON (25-MN-56,2.578HR,DG,847.,0.99) 3308000200010 MONIT-REF (41240001,A.A.Filatenkov+,R,RI-252,1999) 3308000200011 METHOD (ACTIV) Irradiated for 5400 sec., then measured for 3308000200012 900 sec. 3308000200013 (MOMIX) SeO2 and Fe powder (total weight of ~1 g) 3308000200014 packed in a polyethylene bag (10 mm x 10 mm) 3308000200015 ERR-ANALYS (MONIT-ERR,2.,3.7) cross section 56Fe(n,p)56Mn (2-3.7%)3308000200016 STATUS (TABLE) Table II of Phys.Rev.C90(2014)064609 3308000200017 ENDBIB 15 0 3308000200018 NOCOMMON 0 0 3308000200019 DATA 3 5 3308000200020 EN DATA DATA-ERR 3308000200021 MEV MB MB 3308000200022 13.73 15.6 1.5 3308000200023 14.07 17. 1.6 3308000200024 14.42 18.6 1.6 3308000200025 14.68 20.4 1.7 3308000200026 14.77 22. 1.7 3308000200027 ENDDATA 7 0 3308000200028 ENDSUBENT 27 0 3308000299999 SUBENT 33080003 20150108 31683308000300001 BIB 9 16 3308000300002 REACTION (34-SE-80(N,P)33-AS-80,,SIG) 3308000300003 SAMPLE (34-SE-80,NAT=0.4961) 3308000300004 Natural SeO2 (purity of 99.99%) powder 3308000300005 (9-F-19,NAT=1.) 3308000300006 CaF2 (purity of 99.99%) powder 3308000300007 DECAY-DATA (33-AS-80,15.2SEC,DG,666.,0.42) 3308000300008 MONITOR (9-F-19(N,P)8-O-19,,SIG) 3308000300009 DECAY-MON (8-O-19,26.91SEC,DG,197.,0.96, 3308000300010 DG,1357.,0.504) 3308000300011 MONIT-REF (22824001,I.A.Reyhancan,J,ANE,30,1001,2003) 3308000300012 METHOD Pneumatic sample transfer system used. 3308000300013 (ACTIV) Irradiated for 60 sec., then measured for 3308000300014 60 sec. 3308000300015 (MOMIX) SeO2 and CaF2 powder (total weight of ~1 g) 3308000300016 ERR-ANALYS (MONIT-ERR,,5.28) cross section 19F(n,p)19O (<5.28%) 3308000300017 STATUS (TABLE) Table II of Phys.Rev.C90(2014)064609 3308000300018 ENDBIB 16 0 3308000300019 NOCOMMON 0 0 3 3308000300020 DATA 3 5 3308000300021 EN DATA DATA-ERR 3308000300022 MEV MB MB 3308000300023 13.73 4.8 0.63 3308000300024 14.07 7.1 0.95 3308000300025 14.42 8.6 1.1 3308000300026 14.68 9.6 1.4 3308000300027 14.77 11. 1.6 3308000300028 ENDDATA 7 0 3308000300029 ENDSUBENT 28 0 3308000399999 ENDENTRY 3 0 3308099999999