ENTRY 33092 20220830 32083309200000001 SUBENT 33092001 20220830 32083309200100001 BIB 15 43 3309200100002 TITLE Measurement of the 115In(n,g)116mIn reaction cross- 3309200100003 section at the neutron energies of 1.12, 2.12, 3.12 3309200100004 and 4.12 MeV 3309200100005 AUTHOR (B.M.Lawriniang, S.Badwar, R.Ghosh, B.Jyrwa, V.Vansola,3309200100006 H.Naik, A.Goswami, Y.Naik, C.S.Datrik, A.K.Gupta, 3309200100007 V.P.Singh, S.S.Pol, N.B.Subramanyam, A.Agarwal, 3309200100008 P.Singh) 3309200100009 INSTITUTE (3INDBDA,3INDTRM) 3309200100010 (3INDIND) North Eastern Hill Univ., Shillong 3309200100011 REFERENCE (J,KPS,67,441,2015) 3309200100012 FACILITY (VDG,3INDTRM) FOTIA Van de Graff for 3 and 4 MeV 3309200100013 protons 3309200100014 (VDGT,3INDTRM) 14 UD Pelletron Accelerator for 5 and 3309200100015 6 MeV protons 3309200100016 SAMPLE In metal foil of about (98.8-163.7 mg, ~99.99% purity) 3309200100017 and Au metal foil 52.7-59.1 mg were wrapped with 3309200100018 0.025 mm thick Al foil. 3309200100019 INC-SOURCE (P-LI7) The incident proton energies were 3, 4, 5 and 3309200100020 6 MeV. The neutron flux was 10**7 n/cm**2.s 3309200100021 DETECTOR (HPGE) 80 cc HPGe detector coupled to a PC based 4 K 3309200100022 channel analyzer. The detector resolution was 2 keV 3309200100023 for 1332 keV gamma ray of 60Co. 3309200100024 METHOD (GSPEC) 3309200100025 (ACTIV) The irradiation time was 8.6, 5.6, 11.8 and 3309200100026 13.4 hours for 1.12, 2.12, 3.12 and 4.12 MeV 3309200100027 respectively. The Indium and Gold samples were cooled 3309200100028 for 0.7 - 1.25 h and 2.3 - 19 h respectively. 3309200100029 MONITOR (79-AU-197(N,G)79-AU-198,,SIG) 3309200100030 DECAY-MON (79-AU-198-G,2.6948D,DG,411.8,0.9562) 3309200100031 MONIT-REF ((MONIT1),A.Paulsen+,J,AKE,26,80,1975) 3309200100032 ((MONIT2),M.B.Chadwick+,J,NDS,107,2931,2006) 3309200100033 ((MONIT3),K.Shibata+,J,NST,48,1,2011) 3309200100034 FLAG (1.) Data normalized with MONIT1 3309200100035 (2.) Data normalized with MONIT2 3309200100036 (3.) Data normalized with MONIT3 3309200100037 ERR-ANALYS (ERR-T) Total uncertainty (4.2-7.6%) 3309200100038 (ERR-S,2.1,6.7) Counting statistics (2.1-6.7%) 3309200100039 (ERR-SYS) Total systematic error (~3.6%) 3309200100040 (ERR-1) Irradiation time (~0.1%) 3309200100041 (ERR-2) Half life and gamma branching ratio (~2%) 3309200100042 (ERR-3) Detection efficiency (~3%) 3309200100043 HISTORY (20170308C) Compiled by M.R.Srinivasan+BL 3309200100044 (20220830A) VT. Revision in 002 3309200100045 ENDBIB 43 0 3309200100046 COMMON 4 3 3309200100047 ERR-SYS ERR-1 ERR-2 ERR-3 3309200100048 PER-CENT PER-CENT PER-CENT PER-CENT 3309200100049 3.6 0.1 2. 3. 3309200100050 ENDCOMMON 3 0 3309200100051 ENDSUBENT 50 0 3309200199999 SUBENT 33092002 20220830 32083309200200001 BIB 4 9 3309200200002 REACTION (49-IN-115(N,G)49-IN-116-M1+M2,,SIG) 3309200200003 DECAY-DATA (49-IN-116-M1,54.29MIN,DG,138.29,0.037, 3309200200004 DG,416.90,0.272, 3309200200005 DG,818.68,0.1213, 3309200200006 DG,1097.28,0.585, 3309200200007 DG,1293.56,0.848) 3309200200008 STATUS (TABLE) Table 2 of Journal of Korean Physical 3309200200009 Society, 67(2015)441 3309200200010 HISTORY (20220830A) VT. REACTION: SF4:M->M1+M2 replaced 3309200200011 ENDBIB 9 0 3309200200012 NOCOMMON 0 0 3309200200013 DATA 6 10 3309200200014 EN EN-RSL DATA ERR-T MONIT FLAG 3309200200015 MEV MEV MB MB MB NO-DIM 3309200200016 1.12 0.12 271.331 3.374 90.98 1.3309200200017 1.12 0.12 231.285 2.876 77.552 2.3309200200018 1.12 0.12 233.318 2.901 78.234 3.3309200200019 2.12 0.15 120.412 1.631 49.70 1.3309200200020 2.12 0.15 114.711 1.554 47.347 2.3309200200021 2.12 0.15 122.864 1.664 50.712 3.3309200200022 3.12 0.21 41.348 0.538 22.712 1.3309200200023 3.12 0.21 49.247 0.641 18.558 2.3309200200024 4.12 0.22 17.839 2.469 11.490 1.3309200200025 4.12 0.22 18.280 2.511 11.637 2.3309200200026 ENDDATA 12 0 3309200200027 ENDSUBENT 26 0 3309200299999 ENDENTRY 2 0 3309299999999