ENTRY 33096 20170306 31783309600000001 SUBENT 33096001 20170306 31783309600100001 BIB 14 40 3309600100002 TITLE Measurement of 197Au(n,g)198gAu reaction 3309600100003 cross-section at the neutron energies of 1.12, 2.12, 3309600100004 3.12 and 4.12 MeV 3309600100005 AUTHOR (V.Vansola, R.Ghosh, S.Badwar, B.M.Lawriniang, 3309600100006 A.Gopalakrishna, H.Naik, Y.Naik, N.S.Tawade, 3309600100007 S.C.Sharma, J.P.Bhatt, S.K.Gupta, S.Sarode, 3309600100008 S.Mukherjee, N.L.Singh, P.Singh, A.Goswami) 3309600100009 INSTITUTE (3INDBDA,3INDTRM) 3309600100010 (3INDIND) North Eastern Hill Univ., Shillong 3309600100011 (3INDIND) Radiation Medicine Centre, Mumbai 3309600100012 REFERENCE (J,RCA,103,817,2015) 3309600100013 FACILITY (VDG,3INDTRM) The first experiment with the neutron 3309600100014 energies of 1.12, 2.12 MeV was performed using the 3309600100015 folded tandem ion beam accelerator 3309600100016 (VDGT,3INDTRM) 14UD BARC-TIFR Pelletron facility at 3309600100017 TIFR,with neutron energies of 3.12,4.12MeV 3309600100018 INC-SOURCE (P-LI7) LiF target bombarded by proton energies of 3309600100019 3,4,5 and 6 MeV. 3309600100020 SAMPLE Au(59 to 59.4 mg) and In(58.1-64.3 mg) metal foils 3309600100021 wrapped with 0.025 mm thick aluminium foil. 3309600100022 DETECTOR (HPGE) High-purity germanium detector pre-calibrated 3309600100023 80 cm3 HPGe detector couple to a PC based 4094 3309600100024 channel analyser. The resolution of the detector 3309600100025 system during counting was 2.0 keV at 1332 keV of 60Co.3309600100026 METHOD (ACTIV,GSPEC) 3309600100027 MONITOR (49-IN-115(N,G)49-IN-116-M,,SIG) 3309600100028 MONIT-REF ((MONIT),K.I.Zolotarev+,R,INDC(NDS)-0657,2013) 3309600100029 DECAY-MON (49-IN-116-M1,54.29MIN,DG,138.29,0.037, 3309600100030 DG,416.9,0.273, 3309600100031 DG,818.68,0.1213, 3309600100032 DG,1097.28,0.585, 3309600100033 DG,1293.56,0.848) 3309600100034 ERR-ANALYS (ERR-T) Total uncertainty (4.8-6.6%) 3309600100035 (ERR-S,3.1,5.5) Counting statistics (3.1-5.5%) 3309600100036 (ERR-SYS) total systematic error (3.6%) is due to: 3309600100037 (ERR-1) due to irriadiation time(~0.1%) 3309600100038 (ERR-2) due to half life of the reaction products and 3309600100039 gamma ray abundances(~2%) 3309600100040 (ERR-3) Due to detector efficiency(~3%) 3309600100041 HISTORY (20170306C) Sachhidananda H.B 3309600100042 ENDBIB 40 0 3309600100043 COMMON 4 3 3309600100044 ERR-SYS ERR-1 ERR-2 ERR-3 3309600100045 PER-CENT PER-CENT PER-CENT PER-CENT 3309600100046 3.6 0.1 2. 3. 3309600100047 ENDCOMMON 3 0 3309600100048 ENDSUBENT 47 0 3309600199999 SUBENT 33096002 20170306 31783309600200001 BIB 4 5 3309600200002 REACTION (79-AU-197(N,G)79-AU-198,,SIG) 3309600200003 DECAY-DATA (79-AU-198-G,2.6747D,DG,411.8,0.9562) 3309600200004 ADD-RES There exist cross sections measured with 3309600200005 115In(n,g)116mIn monitor cross sections 3309600200006 STATUS (TABLE) Table 2 Radiochim. Acta,103(2015)817 3309600200007 ENDBIB 5 0 3309600200008 NOCOMMON 0 0 3309600200009 DATA 6 4 3309600200010 EN EN-ERR DATA ERR-T MONIT MONIT-ERR 3309600200011 MEV MEV MB MB MB MB 3309600200012 1.12 0.12 60.441 3.403 174.4 6.73309600200013 2.12 0.15 40.588 3.063 104.1 4.53309600200014 3.12 0.21 19.771 2.673 37.5 1.53309600200015 4.12 0.32 13.944 1.611 15.6 0.73309600200016 ENDDATA 6 0 3309600200017 ENDSUBENT 16 0 3309600299999 ENDENTRY 2 0 3309699999999