ENTRY 33112 20181107 31873311200000001 SUBENT 33112001 20181107 31873311200100001 BIB 11 38 3311200100002 TITLE Measurement and estimation of cross sections for 3311200100003 55Mn(n,g)56Mn and 65Cu(n,g)66Cu reactions using 3311200100004 accelerator-based neutron source 3311200100005 AUTHOR (Mehdi S.Barough, V.D.Bharud, B.J.Patil, F.M.D.Attar, 3311200100006 V.N.Bhoraskar, S.D.Dhole) 3311200100007 INSTITUTE (3INDPOO) 3311200100008 (3INDIND) Abasaheb Garware College, Karve Road, Pune, 3311200100009 Maharashtra 3311200100010 (3INDIND) Poona College, K.B. Hidayatullah Road, Pune, 3311200100011 Maharashtra 3311200100012 REFERENCE (J,NSE,187,302,2017) 3311200100013 FACILITY (MICRT,3INDPOO) 6-MeV racetrack microtron accelerator- 3311200100014 based neutron source. 3311200100015 SAMPLE Powders of pure chemical compounds of manganese 3311200100016 (MnO2,99% purity) and copper sheet(99% purity) were 3311200100017 used. The sample were packed a known weight in a 3311200100018 polyethylene bag using microbalance. The size of each 3311200100019 sample was ~6 cm x ~3 cm and ~0.1 cm thick. 3311200100020 DETECTOR (HPGE) The high-purity germanium detector-based gamma 3311200100021 ray spectroscopy was used for the measurement of 3311200100022 induced gamma activity. The HPGe detector was 3311200100023 connected through computer-based multichannel analyzer.3311200100024 INC-SOURCE (PHOTO) A 6 MeV energy electrons beam interact with 3311200100025 tungsten target, produce bremsstrahlung radiation, 3311200100026 which further interact with beryllium target to 3311200100027 produce continuous energy spectrum. 3311200100028 INC-SPECT Neutron spectrum was simulated by FLUKA 3311200100029 ERR-ANALYS (ERR-T) Total uncertainty 3311200100030 (ERR-1) Uncertainties of irradiation, cooling and 3311200100031 counting times (0.1%) 3311200100032 (ERR-2) Isotopic abundance (0.1%) 3311200100033 (ERR-3) Counting statistics (6%) 3311200100034 (ERR-4) Weight of sample (1e-04%) 3311200100035 (ERR-5) Self-absorption of gamma ray (~0.5%) 3311200100036 (ERR-6) Coincidence sum effect of cascade gamma ray 3311200100037 (1%) 3311200100038 (ERR-7) Detector efficiency (3%) 3311200100039 HISTORY (20181107C) VT 3311200100040 ENDBIB 38 0 3311200100041 COMMON 7 6 3311200100042 ERR-1 ERR-2 ERR-3 ERR-4 ERR-5 ERR-6 3311200100043 ERR-7 3311200100044 PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT 3311200100045 PER-CENT 3311200100046 0.1 0.1 6. 0.0001 0.5 1.3311200100047 3. 3311200100048 ENDCOMMON 6 0 3311200100049 ENDSUBENT 48 0 3311200199999 SUBENT 33112002 20181107 31873311200200001 BIB 4 10 3311200200002 REACTION (25-MN-55(N,G)25-MN-56,,SIG,,SPA) 3311200200003 DECAY-DATA (25-MN-56,2.578HR,DG,847.,0.99, 3311200200004 DG,1811.,0.29, 3311200200005 DG,2110.,0.15, 3311200200006 DG,2523.,0.001, 3311200200007 DG,2658.,0.0065, 3311200200008 DG,2957.,0.0031) 3311200200009 METHOD (ACTIV) Irrad./Cool./Counting= 3600+-3.6/30+-0.03/ 3311200200010 3600+-3.6 seconds 3311200200011 STATUS (TABLE) Table 3-4 of Nucl.Sci.Eng.187(2O17)302 3311200200012 ENDBIB 10 0 3311200200013 NOCOMMON 0 0 3311200200014 DATA 4 1 3311200200015 EN-MIN EN-MAX DATA ERR-T 3311200200016 KEV MEV MB MB 3311200200017 1. 4. 8.5 0.578 3311200200018 ENDDATA 3 0 3311200200019 ENDSUBENT 18 0 3311200299999 SUBENT 33112003 20181107 31873311200300001 BIB 5 6 3311200300002 REACTION (29-CU-65(N,G)29-CU-66,,SIG,,SPA) 3311200300003 SAMPLE (29-CU-65,NAT=0.3083) 3311200300004 DECAY-DATA (29-CU-66,5.1MIN,DG,1039.,0.09) 3311200300005 METHOD (ACTIV) Irrad./Cool./Counting= 600+-0.6/30+-0.03/600+- 3311200300006 0.6 seconds 3311200300007 STATUS (TABLE) Table 3-4 of Nucl.Sci.Eng.187(2O17)302 3311200300008 ENDBIB 6 0 3311200300009 NOCOMMON 0 0 3311200300010 DATA 4 1 3311200300011 EN-MIN EN-MAX DATA ERR-T 3311200300012 KEV MEV MB MB 3311200300013 1. 4. 4.5 0.306 3311200300014 ENDDATA 3 0 3311200300015 ENDSUBENT 14 0 3311200399999 ENDENTRY 3 0 3311299999999