ENTRY 40183 20190422 41824018300000001 SUBENT 40183001 20190422 41824018300100001 BIB 14 47 4018300100002 INSTITUTE (4RUSKUR) 4018300100003 REFERENCE (J,NP/A,147,205,1970) 4018300100004 ((R,YFI-6,44,1968)= 4018300100005 (R,INDC(CCP)-3R,44,1968)) INDC(CCP)-3R 4018300100006 Data given 4018300100007 (R,INDC(CCP)-3,44,1968) Engl.transl. of INDC(CCP)-3R 4018300100008 (C,68DUBNA,,14,1968) Data given 4018300100009 AUTHOR (G.V.Muradian,Yu.G.Shchepkin,Yu.V.Adamchuk, 4018300100010 M.G.Arutyunov) 4018300100011 TITLE S- and P-levels of 120Sn 4018300100012 FACILITY (LINAC,4RUSKUR) Electron linear accelerator 4018300100013 Pulse length 0.2 msec, current 0.5 A, frequency 244 Hz.4018300100014 SAMPLE Enrichment on Sn-120 better than 97%. 4018300100015 Sample diameter 70 mm 4018300100016 Type of measurement. Sample thickness 4018300100017 Transmission. 0.0191, 0.0841 and4018300100018 0.1119 atoms/b 4018300100019 Capture and 0.0072, 0.014 and4018300100020 self-indication. 0.0191 atoms/b 4018300100021 METHOD (TOF) Time-of-flight method. 4018300100022 Type of measurement. Resolution. Flight Path. 4018300100023 nsec/m m 4018300100024 Transmission. 3.8 109. 4018300100025 Capture and 12. 37. 4018300100026 self-indication. 4018300100027 DETECTOR Scintillation detectors 4018300100028 (NAICR) 200 x 100 mm NaI(Tl) crystal protected by B-10 4018300100029 of 3.5cm thick. 4018300100030 (BF3) BF3 counter as monitor. 4018300100031 PART-DET (N) Neutrons 4018300100032 (G) Gammas 4018300100033 ANALYSIS (AREA) Area analysis used at level parameter 4018300100034 definition with account of interference 4018300100035 of potential and resonance scattering. 4018300100036 Doppler effect and resolution function 4018300100037 also were accounted 4018300100038 MONITOR BF3 counter as monitor. 4018300100039 CORRECTION Corrected for dead time, background 4018300100040 and capture happened after scattering 4018300100041 COMMENT Method of moving sample used for orbital 4018300100042 momentum identification of levels (see Phys.Letters4018300100043 14,123,1965). Sample speed 135 m/sec 4018300100044 HISTORY (19740429C) Compiled at the centre 4018300100045 (19901011U) All author's names corrected 4018300100046 ISO-QUANT into REACTION converted 4018300100047 (20190422A) Refs.NP/A,147,205,1970, INDC(CCP)-3R, 4018300100048 INDC(CCP)-3 were added. STATUS information was updated.4018300100049 ENDBIB 47 0 4018300100050 NOCOMMON 0 0 4018300100051 ENDSUBENT 50 0 4018300199999 SUBENT 40183002 20190422 41824018300200001 BIB 3 14 4018300200002 REACTION (50-SN-120(N,EL),,WID,,G) 4018300200003 ERR-ANALYS In self-indication measurements principal4018300200004 errors were statistical evaluated 5-10 4018300200005 per-cent. In capture measurements 4018300200006 principal errors were stipulated of 4018300200007 inaccuracy of detector efficiency, which 4018300200008 changed +-20 percent at transition from 4018300200009 resonance to resonance. 4018300200010 (ERR-1,,1.5) Error in the reduction of neutron flux 4018300200011 measurement runs < 1.5%. 4018300200012 (DATA-ERR) Type of uncertainty is not explained in the 4018300200013 article. 4018300200014 STATUS (TABLE) Table 2 of J.Nucl.Phys.A,v.147,p.205,1979 4018300200015 = Table 1 of Yad.Fiz.Issl.,is.6,p.44,1968 4018300200016 ENDBIB 14 0 4018300200017 NOCOMMON 0 0 4018300200018 DATA 4 21 4018300200019 EN-RES DATA DATA-ERR MOMENTUM L 4018300200020 EV MILLI-EV PER-CENT NO-DIM 4018300200021 67.32 0.035 30. 4018300200022 150. 0.045 20. 4018300200023 365.2 3.04 5. 1. 4018300200024 427.2 11.1 6. 1. 4018300200025 922.6 22. 20. 1. 4018300200026 951.8 100. 10. 0. 4018300200027 1288. 17. 6. 1. 4018300200028 1424. 35. 40. 1. 4018300200029 1720. 187. 8. 1. 4018300200030 2837. 45. 28. 1. 4018300200031 3128. 780. 13. 0. 4018300200032 3859. 100. 25. 1. 4018300200033 4273. 30. 50. 4018300200034 4379. 800. 20. 1. 4018300200035 5035. 110. 35. 4018300200036 5080. 400. 25. 4018300200037 7335. 180. 35. 4018300200038 7497. 70. 50. 4018300200039 8157. 900. 30. 4018300200040 9017. 6560. 5. 0. 4018300200041 9587. 3100. 25. 4018300200042 ENDDATA 23 0 4018300200043 ENDSUBENT 42 0 4018300299999 SUBENT 40183003 20190422 41824018300300001 BIB 3 14 4018300300002 REACTION (50-SN-120(N,G),,WID) 4018300300003 ERR-ANALYS In self-indication measurements principal4018300300004 errors were statistical evaluated 5-10 4018300300005 per-cent. In capture measurements 4018300300006 principal errors were stipulated of 4018300300007 inaccuracy of detector efficiency, which 4018300300008 changed +-20 percent at transition from 4018300300009 resonance to resonance. 4018300300010 (ERR-1,,1.5) Error in the reduction of neutron flux 4018300300011 measurement runs < 1.5%. 4018300300012 (DATA-ERR) Type of uncertainty is not explained in the 4018300300013 article. 4018300300014 STATUS (TABLE) Table 2 of J.Nucl.Phys.A,v.147,p.205,1979 4018300300015 = Table 1 of Yad.Fiz.Issl.,is.6,p.44,1968 4018300300016 ENDBIB 14 0 4018300300017 NOCOMMON 0 0 4018300300018 DATA 3 5 4018300300019 EN-RES DATA DATA-ERR 4018300300020 EV MILLI-EV PER-CENT 4018300300021 365.2 127. 20. 4018300300022 427.2 202. 13. 4018300300023 951.8 76. 30. 4018300300024 1288. 122. 25. 4018300300025 1720. 85. 30. 4018300300026 ENDDATA 7 0 4018300300027 ENDSUBENT 26 0 4018300399999 SUBENT 40183004 20190422 41824018300400001 BIB 4 14 4018300400002 REACTION (50-SN-120(N,G),,WID,,AV) 4018300400003 COMMENT Level 427.2 eV did not accounted 4018300400004 ERR-ANALYS In self-indication measurements principal4018300400005 errors were statistical evaluated 5-10 4018300400006 per-cent. In capture measurements 4018300400007 principal errors were stipulated of 4018300400008 inaccuracy of detector efficiency, which 4018300400009 changed +-20 percent at transition from 4018300400010 resonance to resonance. 4018300400011 (ERR-1,,1.5) Error in the reduction of neutron flux 4018300400012 measurement runs < 1.5%. 4018300400013 (DATA-ERR) Type of uncertainty is not explained in the 4018300400014 article. 4018300400015 STATUS (TABLE) Text,p.213 of J.Nucl.Phys.A,v.147,p.205,1979 4018300400016 ENDBIB 14 0 4018300400017 NOCOMMON 0 0 4018300400018 DATA 4 1 4018300400019 EN-RES-MIN EN-RES-MAX DATA DATA-ERR 4018300400020 EV EV MILLI-EV MILLI-EV 4018300400021 365.2 1720. 124. 30. 4018300400022 ENDDATA 3 0 4018300400023 ENDSUBENT 22 0 4018300499999 SUBENT 40183005 20190422 41824018300500001 BIB 4 15 4018300500002 REACTION (50-SN-120(N,EL),,STF) 4018300500003 ERR-ANALYS In self-indication measurements principal4018300500004 errors were statistical evaluated 5-10 4018300500005 per-cent. In capture measurements 4018300500006 principal errors were stipulated of 4018300500007 inaccuracy of detector efficiency, which 4018300500008 changed +-20 percent at transition from 4018300500009 resonance to resonance. 4018300500010 (ERR-1,,1.5) Error in the reduction of neutron flux 4018300500011 measurement runs < 1.5%. 4018300500012 (DATA-ERR) Type of uncertainty is not explained in the 4018300500013 article. 4018300500014 STATUS (TABLE) Text,p.48,50 of Yad.Fiz.Issl.,is.6,p.44,1968 4018300500015 S1 value in abstract of J.Nucl.Phys.A,v.147,p.205,19794018300500016 HISTORY (20190422A) SF3 was corrected: 0 -> EL 4018300500017 ENDBIB 15 0 4018300500018 NOCOMMON 0 0 4018300500019 DATA 6 3 4018300500020 EN-RES-MIN EN-RES-MAX MOMENTUM L DATA +DATA-ERR -DATA-ERR 4018300500021 EV EV NO-DIM NO-DIM NO-DIM NO-DIM 4018300500022 67. 4379. 0. 0.0000043 0.000006 0.000002 4018300500023 365. 4379. 1. 0.00037 0.00018 0.00009 4018300500024 952. 9017. 0. 0.000009 0.000015 0.000005 4018300500025 ENDDATA 5 0 4018300500026 ENDSUBENT 25 0 4018300599999 SUBENT 40183006 20190422 41824018300600001 BIB 3 5 4018300600002 REACTION (50-SN-120(N,0),,J) 4018300600003 STATUS (TABLE) Table 1 of Yad.Fiz.Issl.,is.6,p.44,1968 4018300600004 COMMENT In Table 2 of J.Nucl.Phys.A,v.147,p.205,1979 4018300600005 spins J are given only for two resonances: 4018300600006 922.6 eV - (3/2), 1720.eV - 1/2 . 4018300600007 ENDBIB 5 0 4018300600008 NOCOMMON 0 0 4018300600009 DATA 2 4 4018300600010 EN-RES DATA 4018300600011 EV NO-DIM 4018300600012 922.6 2. 4018300600013 951.8 1. 4018300600014 1720. 1. 4018300600015 3128. 1. 4018300600016 ENDDATA 6 0 4018300600017 ENDSUBENT 16 0 4018300699999 SUBENT 40183007 20190422 41824018300700001 BIB 5 18 4018300700002 REACTION (50-SN-120(N,EL),,STF) 4018300700003 ERR-ANALYS In self-indication measurements principal4018300700004 errors were statistical evaluated 5-10 4018300700005 per-cent. In capture measurements 4018300700006 principal errors were stipulated of 4018300700007 inaccuracy of detector efficiency, which 4018300700008 changed +-20 percent at transition from 4018300700009 resonance to resonance. 4018300700010 (ERR-1,,1.5) Error in the reduction of neutron flux 4018300700011 measurement runs < 1.5%. 4018300700012 (DATA-ERR) Type of uncertainty is not explained in the 4018300700013 article. 4018300700014 STATUS (TABLE) Text,p.213 of J.Nucl.Phys.A,v.147,p.205,1979 4018300700015 =Text,p.48 of Yad.Fiz.Issl.,is.6,p.44,1968 4018300700016 COMMENT Of compiler. Value S0= (0.08 +0.1 -0.04)*10**-4 is 4018300700017 given in abstract of J.Nucl.Phys.A,v.147,p.205,1979 4018300700018 HISTORY (19901011C) ++ Compiled at the centre - CJD ++ 4018300700019 (20190422A) SF3 was corrected: 0 -> EL 4018300700020 ENDBIB 18 0 4018300700021 NOCOMMON 0 0 4018300700022 DATA 6 1 4018300700023 EN-RES-MIN EN-RES-MAX MOMENTUM L DATA +DATA-ERR -DATA-ERR 4018300700024 EV EV NO-DIM NO-DIM NO-DIM NO-DIM 4018300700025 67. 9017. 0. 7.E-06 1.2E-05 4.E-064018300700026 ENDDATA 3 0 4018300700027 ENDSUBENT 26 0 4018300799999 ENDENTRY 7 0 4018399999999