ENTRY 41266 20220311 42064126600000001 SUBENT 41266001 20220311 42064126600100001 BIB 12 33 4126600100002 TITLE Identification of 93Nb levels from angular momentum 4126600100003 analysis of incoming neutron 4126600100004 AUTHOR (H.V.Muradyan,Yu.V.Adamchuk) 4126600100005 INSTITUTE (4RUSKUR) 4126600100006 REFERENCE (S,EANDC-50-S,(2),(183),1965) Proc.of 65ANTWERP 4126600100007 In INDC(EAN)*003G=INDSWG-109=EANDC-44 (Abstracts of 4126600100008 65ANTWERP, at NDS web-site) the abstract of this 4126600100009 article is absent. 4126600100010 Abstract book 65ANTWERP,p.570,paper 183,1965 4126600100011 REL-REF (M,41665001,H.V.Muradyan,J,PL,14,123,1965) Issue 2. 4126600100012 #doi:10.1016/0031-9163(65)90448-8 4126600100013 (R,11905001,J.B.Garg+,J,PR,137,B547,1965) 4126600100014 Resonance parameters used. 4126600100015 FACILITY (LINAC,4RUSKUR) Neutron pulse duration 0.2 microsec, 4126600100016 the width of 2048 channel time analyzer 0.25 microsec.4126600100017 MONITOR Resonance area for Cu-65 at E0=221 eV was used as 4126600100018 monitor time in measurements. 4126600100019 SAMPLE .Nb samples were made as metal disks 70 mm in diameter 4126600100020 with less than 0.2 % Ta impurity. To avoid 4126600100021 multiple scattering, one sample was split into two 4126600100022 thinner samples and placed 30 mm from each other. 4126600100023 Rotating sample technique with a linear velocity of 4126600100024 63 m/sec was used. 4126600100025 METHOD (TOF) Flight path of 37 m 4126600100026 DETECTOR (NAICR) Two NaI(Tl) crystals with 150 mm diameter, 4126600100027 efficiency of neutron capture ~50 %, 4126600100028 resolution time 0.2 microsec. 4126600100029 Spectrometer resolution ~10 nsec/m. 4126600100030 ERR-ANALYS .No discussion given 4126600100031 HISTORY (19971230C) + + Compiled at the center - CJD + + 4126600100032 (20220311A) Update for current rules and dictionaries. 4126600100033 C,65ANTWERP,,(183),6507 was replaced by 4126600100034 S,EANDC-50-S,(2),(183),1965. 4126600100035 ENDBIB 33 0 4126600100036 NOCOMMON 0 0 4126600100037 ENDSUBENT 36 0 4126600199999 SUBENT 41266002 20220311 42064126600200001 BIB 5 10 4126600200002 REACTION (41-NB-93(N,0),,L) 4126600200003 ANALYSIS In case of S level A- > A+, in case of P-level A-=A+, 4126600200004 parameter K=2*(A- - A+)/(A- + A+) was determined, 4126600200005 A- is resonance area in case of sample moving in the 4126600200006 direction of the neutron beam, A+ is one for the 4126600200007 opposite direction. 4126600200008 FLAG (1.) Angular momentum assignment is uncertain 4126600200009 STATUS (TABLE) Table of 4126600200010 Conf.Proc.rep.EANDC-50-S,V.2,paper 183,1965 4126600200011 HISTORY (19971230T) Converted from Subent 80509002 4126600200012 ENDBIB 10 0 4126600200013 NOCOMMON 0 0 4126600200014 DATA 3 33 4126600200015 EN-RES DATA FLAG 4126600200016 EV NO-DIM NO-DIM 4126600200017 35.5 1. 1. 4126600200018 42.5 1. 1. 4126600200019 95.5 1. 4126600200020 105.8 0. 4126600200021 119.2 0. 4126600200022 193.8 0. 4126600200023 243.7 1. 4126600200024 319.0 0. 4126600200025 335.5 0. 4126600200026 365.0 0. 1. 4126600200027 378.5 0. 4126600200028 392.4 1. 4126600200029 460.3 0. 4126600200030 500.3 1. 4126600200031 599.3 0. 1. 4126600200032 603.7 0. 1. 4126600200033 617.8 1. 1. 4126600200034 640.7 0. 4126600200035 671.9 1. 4126600200036 678.2 1. 4126600200037 721.2 1. 4126600200038 741.2 0. 4126600200039 911.8 0. 1. 4126600200040 934.1 0. 4126600200041 952.0 1. 4126600200042 1008.5 0. 4126600200043 1016.0 1. 1. 4126600200044 1107.0 0. 4126600200045 1126.5 0. 4126600200046 1147.5 0. 4126600200047 1175.0 0. 4126600200048 1193.0 0. 4126600200049 1228.0 0. 4126600200050 ENDDATA 35 0 4126600200051 ENDSUBENT 50 0 4126600299999 ENDENTRY 2 0 4126699999999