ENTRY A0342 20041206 A061A034200000001 SUBENT A0342001 20041206 A061A034200100001 BIB 11 43 A034200100002 TITLE Stopping power, electron screening and the A034200100003 astrophysical S(E) factor of d(3-He,p)4-He A034200100004 REFERENCE (J,PL/B,482,43,2000) A034200100005 AUTHOR (H.Costantini, A.Formicola, M.Junker, R.Bonetti, A034200100006 C.Broggini, L.Campajola, P.Corvisiero, A.D'Onofrio, A034200100007 A.Fubini, G.Gervino, L.Gialanella, U.Greife, A034200100008 A.Guglielmetti, C.Gustavino, G.Imbriani, A.Ordine, A034200100009 P.G.Prada Moroni, P.Prati, V.Roca, D.Rogalla, C.Rolfs, A034200100010 M.Romano, F.Schuemann, O.Straniero, F.Strieder, A034200100011 F.Terrasi, H.P.Trautvetter, S.Zavatarelli) A034200100012 INSTITUTE (2ITYGVA) Dipartimento di fisica, A034200100013 (2ITYNAP) Dipartimento di scienze fisiche A034200100014 (2ITYFSN) Dipartimento di scienze ambientali, A034200100015 (2ITYFRA) Enea, frascati and INFN, torino A034200100016 (2ITYMIL) Dipartimento di fisica A034200100017 (2ITYTUR) Dipartimento di fisica sperimentale A034200100018 (2GERBOC) Institut fuer physik mit ionenstrahlen A034200100019 (1USACSM) Department of physics A034200100020 (2ITYLGS) A034200100021 (2ITYITY) Osservatorio astronomico di capodimonte and A034200100022 osservatorio astronomico di collurania, teramo. A034200100023 SAMPLE Gas-target system. The deuterim gas pressure was A034200100024 measured with a relative accuracy of 1% and an absoluteA034200100025 accuracy of 1%. A034200100026 FACILITY (ACCEL,2ITYLGS) National laboratory in Gran Sasso A034200100027 METHOD (SITA) See Sample A034200100028 (BCINT) A beam calorimeter A034200100029 (EXTB) A034200100030 DETECTOR (SIBAR) The detector setup consisted of eight, 1 A034200100031 millimeter thick Si detectors placed around the beam A034200100032 axis. A034200100033 ERR-ANALYS (ERR-S) The error includes beam heating effects on the A034200100034 gas density (1%). A034200100035 (ERR-1) The error includes uncertainty in gas pressure,A034200100036 detection efficiency uncertainty, 5% uncertainty in A034200100037 mean energy loss to the middle of the detector setup. A034200100038 (EN-ERR) Maximal value of He-3 energy spread. A034200100039 HISTORY (20020622C) A034200100040 (20041206D) Deleted. It is same as F0555 A034200100041 (20041206U) Last checking has been done. A034200100042 ADD-RES 1. Stopping power, A034200100043 2. Factor of electron screening was found 132 eV +/- A034200100044 0.3 (statistical) +/- 9 eV (systematic) A034200100045 ENDBIB 43 0 A034200100046 COMMON 1 3 A034200100047 EN-ERR A034200100048 EV A034200100049 20. A034200100050 ENDCOMMON 3 0 A034200100051 ENDSUBENT 50 0 A034200199999 NOSUBENT A0342002 20041206 A061A034200200001 ENDENTRY 2 0 A034299999999