ENTRY A0601 20170206 A086A060100000001 SUBENT A0601001 20170206 A086A060100100001 BIB 13 54 A060100100002 TITLE Fusion cross sections for 7-Li + 16-O at energies aboveA060100100003 barrier A060100100004 AUTHOR (M.Ray, A.Mukherjee, M.Saha Sarkar, A.Goswami, S.Roy, A060100100005 S.Saha, R.Bhattacharya, B.R.Behera, S.K.Datta, A060100100006 B.Dasmahapatra) A060100100007 REFERENCE (J,PR/C,68,067601,2003) A060100100008 REL-REF (M,O0946001,A.Mukherjee+,J,NP/A,596,299,1996) A060100100009 (I,O0948001,A.Mukherjee+,J,NP/A,635,305,1998). A060100100010 (M,,A.Mukherjee+,J,PR/C,63,017604,2000) A060100100011 The details of the measurement of efficiency of the A060100100012 detector and the measurement of different quantities A060100100013 and their uncertainties in the determination of A060100100014 gamma-ray cross sections were described in all refs. A060100100015 (M,O0949001,A.Mukherjee+,J,NP/A,645,13,1999) - A060100100016 branching factor description A060100100017 INSTITUTE (3INDVEC) A060100100018 (3INDSAH) A060100100019 (3INDIND) Gurudas College, Kolkata. A060100100020 (2ITYPAD) A060100100021 (3INDNSD) Nuclear Science Centre, New Delhi. A060100100022 FACILITY (VDGT,3INDNSD) The 14UD Pelletron accelerator at the A060100100023 Nuclear Science Centre, New Delhi. A060100100024 METHOD (SITA) The target was Si-O/2 (self-supporting) having A060100100025 oxygen content (18.0+/-1.1) x 10**17 nuclei/cm2, A060100100026 measured from the elastic scattering data obtained A060100100027 with heavy ion detectors. A060100100028 (BCINT) A060100100029 (GSPEC) A060100100030 DETECTOR (HPGE) The detector was placed at 90 degree with A060100100031 respect to the beam axis. A060100100032 PART-DET (G) A060100100033 ANALYSIS The total gamma-ray yield was obtained by A060100100034 summing the cross sections of 0.332 (21-Na), 0.351, A060100100035 1.395 (21-Ne), 0.937 (18-F), 1.634 (20-Ne), and A060100100036 1.121, 5.270 + 5.299 (15-N) MeV gamma-rays. A060100100037 The total fusion cross sections were obtained from A060100100038 the total gamma-ray cross sections, dividing the A060100100039 latter by the correction factor Fg, as described A060100100040 in ref.(see REL-REF). A060100100041 The anisotropy of the angular distribution of the A060100100042 gamma rays used in the determination of fusion cross A060100100043 section was investigated, and was found to be A060100100044 negligible. A060100100045 ERR-ANALYS (ERR-T) Uncertainty in fusion cross section includes: A060100100046 (ERR-1) Uncertainty in Fg; A060100100047 (ERR-2) Uncertainty in gamma-ray cross sections A060100100048 ADD-RES (COMP) 1. Optical model A060100100049 2. A combination of CDCC/CF (continuum discretized A060100100050 coupled channels/cluster folding) and BPM (barrier A060100100051 penetration model) A060100100052 HISTORY (20040122C) A060100100053 (20040122U) Last checking has been done. A060100100054 (20170206U) SD: Institute code corrected. BIB update. A060100100055 Small correction in Subent 002. DATA-ERR -> ERR-T. A060100100056 ENDBIB 54 0 A060100100057 COMMON 2 3 A060100100058 ERR-1 ERR-2 A060100100059 PER-CENT PER-CENT A060100100060 10. 11. A060100100061 ENDCOMMON 3 0 A060100100062 ENDSUBENT 61 0 A060100199999 SUBENT A0601002 20170206 A086A060100200001 BIB 2 2 A060100200002 REACTION (8-O-16(3-LI-7,FUS),,SIG) A060100200003 STATUS (CURVE) By CAJAD. Fig.1 from PR/C,68,067601,2003 A060100200004 ENDBIB 2 0 A060100200005 COMMON 1 3 A060100200006 EN-ERR-DIG A060100200007 MEV A060100200008 0.15 A060100200009 ENDCOMMON 3 0 A060100200010 DATA 3 8 A060100200011 EN-CM DATA ERR-T A060100200012 MEV MB PER-CENT A060100200013 12.47 1040. 14. A060100200014 13.21 940. 16. A060100200015 13.84 970. 13. A060100200016 16.69 900. 14. A060100200017 18.06 840. 14. A060100200018 19.43 900. 14. A060100200019 20.91 950. 15. A060100200020 23.65 950. 16. A060100200021 ENDDATA 10 0 A060100200022 ENDSUBENT 21 0 A060100299999 ENDENTRY 2 0 A060199999999