ENTRY A0872 20120110 A075A087200000001 SUBENT A0872001 20120110 A075A087200100001 BIB 10 41 A087200100002 TITLE Isomeric and ground-state properties of 78-Pt-171, A087200100003 76-Os-167 and 74-W-163. A087200100004 AUTHOR (C.Scholey, K.Andgren, L.Bianco, B.Cederwall, A087200100005 I.G.Darby, S.Eeckhaudt, S.Ertuerk, M.B.Gomez Hornillos,A087200100006 T.Grahn, P.T.Greenlees, B.Hadinia, E.Ideguchi, P.Jones,A087200100007 D.T.Joss, R.Julin, S.Juutinen, S.Ketelhut, M.Leino, A087200100008 A.-P.Leppaenen, P.Nieminen, M.Niikura, M.Nyman, A087200100009 D.O'Donnell, R.D.Page, J.Pakarinen, P.Rahkila, J.Saren,A087200100010 M.Sandzelius, J.Simpson, J.Sorri, J.Thomson, A087200100011 J.Uusitalo, M.Venhart) A087200100012 INSTITUTE (2SF JYV) A087200100013 (2SWDKTH) A087200100014 (2UK LVP) A087200100015 (2TUKTUK) Department of Physics, Nigde University, A087200100016 Nigde, Turkey A087200100017 (2UK DAR) A087200100018 (2JPNTOK) A087200100019 (3SLKUB) A087200100020 REFERENCE (J,PR/C,81,014306,2010) A087200100021 FACILITY (CYCLO,2SF JYV) Experiment was performed at the A087200100022 Accelerator Laboratory of the University of A087200100023 Jyvaskyla, employing the K130 cyclotron A087200100024 SAMPLE Self-supporting metallic foil enriched in 96Ru to A087200100025 96.5% with thickness of a 500 mu-g/cm2 . A087200100026 DETECTOR (HPGE)Prompt gamma rays were detected at the target A087200100027 position by the JUROGAM array consisting of 43 A087200100028 EUROGAM phase I and GASP type Compton-suppressed A087200100029 germanium detectors. A087200100030 (MAGSP)Gas-filled recoil magnetic separator was used A087200100031 with subsequent implantation of selected ions in a A087200100032 double-sided silicon strip detectors A087200100033 (MWPC) a multi-wire proportional counter A087200100034 (SISD)Double-sided silicon strip detector (DSS)has an A087200100035 effective area of 60x40 mm2, with 200 individual A087200100036 strips at a pitch of 1 mm in both directions, A087200100037 leading to 4800 independent pixels in total. A087200100038 METHOD (TOF) A087200100039 STATUS (TABLE).Table 1 of J,PR/C,81,014306,2010 A087200100040 HISTORY (20110321C) S.B. A087200100041 (20120110A) SB-E-LVL: MEV -> KEV for sub.002-005 A087200100042 E-LVL to E-LVL-MIN for sub.002-005 A087200100043 ENDBIB 41 0 A087200100044 NOCOMMON 0 0 A087200100045 ENDSUBENT 44 0 A087200199999 SUBENT A0872002 20120110 A075A087200200001 BIB 3 3 A087200200002 REACTION (48-CD-106(28-NI-60,X)74-W-163,PAR,SIG) A087200200003 EN-SEC (E-LVL-MIN,74-W-163) A087200200004 SAMPLE Cd-106, thickness 1100 mug/cm**2, was used as target. A087200200005 ENDBIB 3 0 A087200200006 COMMON 1 3 A087200200007 E-LVL-MIN A087200200008 KEV A087200200009 480.3 A087200200010 ENDCOMMON 3 0 A087200200011 DATA 2 1 A087200200012 EN DATA-APRX A087200200013 MEV MB A087200200014 270.0 4. A087200200015 ENDDATA 3 0 A087200200016 ENDSUBENT 15 0 A087200299999 SUBENT A0872003 20120110 A075A087200300001 BIB 3 3 A087200300002 REACTION (42-MO-92(36-KR-78,X)74-W-163,PAR,SIG) A087200300003 EN-SEC (E-LVL-MIN,74-W-163) A087200300004 SAMPLE Mo-92, thickness 500 mug/cm**2, was used as target. A087200300005 ENDBIB 3 0 A087200300006 COMMON 1 3 A087200300007 E-LVL-MIN A087200300008 KEV A087200300009 480.4 A087200300010 ENDCOMMON 3 0 A087200300011 DATA 2 1 A087200300012 EN DATA-APRX A087200300013 MEV MB A087200300014 380.0 0.7 A087200300015 ENDDATA 3 0 A087200300016 ENDSUBENT 15 0 A087200399999 SUBENT A0872004 20120110 A075A087200400001 BIB 3 3 A087200400002 REACTION (42-MO-92(36-KR-78,X)76-OS-167,PAR,SIG) A087200400003 EN-SEC (E-LVL-MIN,76-OS-167) A087200400004 SAMPLE Mo-92, thickness 500 mug/cm**2, was used as target. A087200400005 ENDBIB 3 0 A087200400006 COMMON 1 3 A087200400007 E-LVL-MIN A087200400008 KEV A087200400009 434.3 A087200400010 ENDCOMMON 3 0 A087200400011 DATA 2 2 A087200400012 EN DATA-APRX A087200400013 MEV MB A087200400014 365.0 2.0 A087200400015 357.0 2.0 A087200400016 ENDDATA 4 0 A087200400017 ENDSUBENT 16 0 A087200499999 SUBENT A0872005 20120110 A075A087200500001 BIB 3 3 A087200500002 REACTION (44-RU-96(36-KR-78,X)78-PT-171,PAR,SIG) A087200500003 EN-SEC (E-LVL-MIN,78-PT-171) A087200500004 SAMPLE Ru-96, thickness 500 mug/cm**2, was used as target. A087200500005 ENDBIB 3 0 A087200500006 COMMON 1 3 A087200500007 E-LVL-MIN A087200500008 KEV A087200500009 412.6 A087200500010 ENDCOMMON 3 0 A087200500011 DATA 2 1 A087200500012 EN DATA-APRX A087200500013 MEV MICRO-B A087200500014 348.0 85. A087200500015 ENDDATA 3 0 A087200500016 ENDSUBENT 15 0 A087200599999 ENDENTRY 5 0 A087299999999