ENTRY A0881 20110608 A072A088100000001 SUBENT A0881001 20110608 A072A088100100001 BIB 12 26 A088100100002 TITLE Excitation functions for the radionuclide 46Sc A088100100003 produced in the irradiation of 45Sc with deuterons A088100100004 and 6He. A088100100005 AUTHOR (N.K.Skobelev, A.A.Kulko, V.Kroha, V.Burjan, Z.Hons, A088100100006 A.V.Daniel, N.A.Demekhina, R.Kalpakchieva, A.Kugler, A088100100007 J.Mrazek, Yu.E.Penionzhkevich, S.Piskor, Yu.G.Sobolev, A088100100008 E.Simeckova) A088100100009 INSTITUTE (4ZZZDUB) A088100100010 (3CZRUJF) A088100100011 REFERENCE (J,JP/G,38,035106,2011) final data A088100100012 (J,IZV,75,574,2011) prelim. data A088100100013 (J,BAS,75,538,2011) English translation A088100100014 REL-REF (M,F0837001,Yu.E.Penionzhkevich+,J,EPJ/A,31,185,2007) A088100100015 METHOD (BCINT) A088100100016 (STTA) A088100100017 (ACTIV) A088100100018 MONITOR (22-TI-0(D,X)23-V-48,,SIG) A088100100019 DECAY-MON (23-V-48,15.9735D,DG,944.104,0.0776,DG,983.517,0.9998, A088100100020 DG,1312.096,0.975) A088100100021 MONIT-REF (,F.Tarkanyi+,R,IAEA-TECDOC-1065,113,1999) A088100100022 STATUS (TABLE).Table were received from A.Kulko 22.06.2011 A088100100023 (APRVD).By A.Kulko. A088100100024 ERR-ANALYS (DATA-ERR).The error is shown by authors on figure. A088100100025 (EN-ERR).The error in incident energy is shown by A088100100026 authors on figure. A088100100027 HISTORY (20110608C) SB A088100100028 ENDBIB 26 0 A088100100029 NOCOMMON 0 0 A088100100030 ENDSUBENT 29 0 A088100199999 SUBENT A0881002 20110623 A072A088100200001 BIB 6 24 A088100200002 REACTION (21-SC-45(D,P)21-SC-46,,SIG) A088100200003 DECAY-DATA (21-SC-46,83.79D,DG,889.3,0.9998,DG,1120.545,0.99987) A088100200004 DETECTOR (HPGE) All measurements were performed using an HPGe A088100200005 detector with 50% efficiency with respect to NaI and A088100200006 the FWHM was 1.8 keV for a gamma energy of 1.3 MeV. A088100200007 FACILITY 1(CYCLO,3CZRUJF) the U-120M cyclotron at the Nuclear A088100200008 Physics Institute of the Czech Academy of Sciences A088100200009 2(VDGT,4ZZZDUB) An experiment on an EG-5 electrostatic A088100200010 generator(Laboratory of Neutron Physics, Joint A088100200011 Institute for Nuclear Research) was also performed to A088100200012 reduce the energy spread of deuterons in the A088100200013 subbarrier energy region. A088100200014 SAMPLE 1The stack of targets consisting of scandium foils with A088100200015 thicknesses from 3 to 5 mum was installed at the centerA088100200016 of the reaction chamber, under the deuteron beam. A088100200017 The stack also included titanium foils with thicknessesA088100200018 of 1.8 mum, which were used for the monitor reaction. A088100200019 Aluminium degraders with thicknesses from 5 to 50 mum A088100200020 were installed between targets to reduce the deuteron A088100200021 energy. Deuteron energies of 11.7 to 2.0 MeV were A088100200022 absorbed in the applied arrays of Sc targets. A088100200023 2Scandium foils, thickness, 2 mum, were irradiated by a A088100200024 deuteron beam with an energy varying from 0.9 to 2.5MeVA088100200025 STATUS (TABLE).Table for fig.2 were received from A.Kulko A088100200026 ENDBIB 24 0 A088100200027 NOCOMMON 0 0 A088100200028 DATA 4 18 A088100200029 EN EN-ERR DATA DATA-ERR A088100200030 MEV MEV MB MB A088100200031 11.59 0.12 217. 8.6 A088100200032 10.41 0.14 243. 6.8 A088100200033 9.0 0.17 292. 11.1 A088100200034 7.26 0.23 344. 9.3 A088100200035 7.22 0.23 358. 2.2 A088100200036 5.82 0.26 399. 3.2 A088100200037 5.8 0.26 369. 3.3 A088100200038 4.63 0.33 293. 4.5 A088100200039 3.91 0.33 248. 2.2 A088100200040 3.52 0.39 169. 3.6 A088100200041 2.88 0.41 135. 0.4 A088100200042 2.51 0.49 79.7 4.1 A088100200043 2.46 0.05 38.0 0.6 A088100200044 2.27 0.48 60.1 2.4 A088100200045 2.00 0.62 28.6 1.2 A088100200046 1.95 0.05 8.2 0.2 A088100200047 1.45 0.05 0.8 0.065 A088100200048 0.81 0.05 0.00137 0.0005 A088100200049 ENDDATA 20 0 A088100200050 ENDSUBENT 49 0 A088100299999 SUBENT A0881003 20110623 A072A088100300001 BIB 6 18 A088100300002 REACTION (21-SC-45(D,T)21-SC-44,,SIG) A088100300003 DECAY-DATA (21-SC-44-M,58.69HR,DG,271.13,0.867) A088100300004 (21-SC-44-G,3.927HR,DG,1157.031,0.999) A088100300005 DETECTOR (HPGE) All measurements were performed using an HPGe A088100300006 detector with 50% efficiency with respect to NaI and A088100300007 the FWHM was 1.8 keV for a gamma energy of 1.3 MeV. A088100300008 FACILITY (CYCLO,3CZRUJF) the U-120M cyclotron at the Nuclear A088100300009 Physics Institute of the Czech Academy of Sciences A088100300010 SAMPLE The stack of targets consisting of scandium foils with A088100300011 thicknesses from 3 to 5 mum was installed at the centerA088100300012 of the reaction chamber, under the deuteron beam. A088100300013 The stack also included titanium foils with thicknessesA088100300014 of 1.8 mum, which were used for the monitor reaction. A088100300015 Aluminium degraders with thicknesses from 5 to 50 mum A088100300016 were installed between targets to reduce the deuteron A088100300017 energy. Deuteron energies of 11.7 to 2.0 MeV were A088100300018 absorbed in the applied arrays of Sc targets. A088100300019 STATUS (TABLE).Table for fig.2 were received from A.Kulko A088100300020 ENDBIB 18 0 A088100300021 NOCOMMON 0 0 A088100300022 DATA 5 4 A088100300023 EN EN-ERR DATA DATA-ERR DATA-MAX A088100300024 MEV MEV MB MB MB A088100300025 11.59 0.12 3.18 0.34 A088100300026 10.41 0.14 1.78 0.03 A088100300027 9.0 0.17 1.24 0.14 A088100300028 7.26 0.23 0.014 A088100300029 ENDDATA 6 0 A088100300030 ENDSUBENT 29 0 A088100399999 SUBENT A0881004 20110623 A072A088100400001 BIB 7 23 A088100400002 REACTION 1(21-SC-45(2-HE-6,X)21-SC-46,,SIG) A088100400003 2(21-SC-45(2-HE-6,A)21-SC-47,,SIG) A088100400004 DECAY-DATA1(21-SC-46,83.79D,DG,889.3,0.9998,DG,1120.545,0.99987) A088100400005 2(21-SC-47,3.3492D,DG,159.377,0.683) A088100400006 METHOD (INTB)HE-6 A088100400007 DETECTOR (HPGE) HPGe detectors with an energy resolution of A088100400008 approx. 1.2 keV for E(g)=662 keV were used in the A088100400009 measurements. A088100400010 FACILITY (VDGT,4ZZZDUB) A 6He beam was obtained at the DRIBs A088100400011 accelerator complex for radioactive beams(Laboratory A088100400012 of Nuclear Reactions, Joint Institute for Nuclear A088100400013 Research), which is a tandem of two accelerators U-400MA088100400014 and U-400 (ISOL). A088100400015 SAMPLE The target stack consisted of six Sc foils with A088100400016 thicknesses of 3 to 5 mum. The first stack was A088100400017 irradiated with a calculated 6He energy of 20 MeV. A088100400018 A stack of three Sc foils was irradiated by a 6He beam A088100400019 with an energy of ions incident on the stack of about A088100400020 23 MeV. A088100400021 In both arrays, Al foils with different thicknesses A088100400022 were placed between the Sc targets to measure the 6He A088100400023 energy. A088100400024 STATUS (TABLE).Table for fig.3 were received from A.Kulko A088100400025 ENDBIB 23 0 A088100400026 NOCOMMON 0 0 A088100400027 DATA 5 9 A088100400028 EN DATA 1DATA-ERR 1DATA 2DATA-ERR 2 A088100400029 MEV MB MB MB MB A088100400030 4.86 33.9 7. A088100400031 5.43 39.1 5. A088100400032 7.19 172. 15. A088100400033 8.68 207. 23. A088100400034 9.73 196. 14. A088100400035 11.46 183. 11. A088100400036 21.3 186. 13. 19.09 4.0 A088100400037 22.1 178. 16. 20.4 4.5 A088100400038 22.9 191. 18. 17.4 3.5 A088100400039 ENDDATA 11 0 A088100400040 ENDSUBENT 39 0 A088100499999 ENDENTRY 4 0 A088199999999