ENTRY A1020 20200305 A094A102000000001 SUBENT A1020001 20200305 A094A102000100001 BIB 8 15 A102000100002 TITLE Radiative capture of 3H by 3He A102000100003 AUTHOR (D.Kohler,S.M.Austin) A102000100004 REFERENCE (J,BAP,8,290(A2),1963) A102000100005 INSTITUTE (1USASTF) A102000100006 SAMPLE Tritiated titanium target approximately 200 keV thick A102000100007 to 3-MeV 3He ions A102000100008 MONITOR (1-H-3(P,G)2-HE-4,,SIG) - cross sections were obtained A102000100009 by direct comparison with the T(p,gamma)He4 reaction A102000100010 by using the same target, detection system and geometryA102000100011 DETECTOR (NAICR) 5X6-in. NaI(Tl) Crystal surrounded by a plasticA102000100012 scintillator cosmic-ray anticoincidence shield. A102000100013 HISTORY (19811021C) Compilation produced by Arzamas RFNC-VNIIEFA102000100014 (19961029U) Last checking has been done. A102000100015 (19990115U)CNPD: corrected 4-dig. year and lower cases.A102000100016 (20200305A) SD: Correction in Subent 002. A102000100017 ENDBIB 15 0 A102000100018 NOCOMMON 0 0 A102000100019 ENDSUBENT 18 0 A102000199999 SUBENT A1020002 20200305 A094A102000200001 BIB 4 4 A102000200002 REACTION (1-H-3(HE3,G)3-LI-6,PAR,DA) A102000200003 ERR-ANALYS (DATA-ERR) No information about source of uncertainty A102000200004 STATUS (TABLE) From the Text A102000200005 HISTORY (20200305A) SD: SF9=EXP deleted from REACTION code. A102000200006 ENDBIB 4 0 A102000200007 COMMON 3 3 A102000200008 E-LVL ANG DATA-ERR A102000200009 MEV ADEG PER-CENT A102000200010 0. 90. 40. A102000200011 ENDCOMMON 3 0 A102000200012 DATA 2 2 A102000200013 EN DATA A102000200014 MEV MB/SR A102000200015 1.1 0.0014 A102000200016 3. 0.008 A102000200017 ENDDATA 4 0 A102000200018 ENDSUBENT 17 0 A102000299999 ENDENTRY 2 0 A102099999999