ENTRY A1246 20210317 A097A124600000001 SUBENT A1246001 20210317 A097A124600100001 BIB 10 45 A124600100002 TITLE Angular distribution of the T(d,n)4He reaction at A124600100003 1, 1.5 and 2 MeV deuteron energy A124600100004 AUTHOR (L.Jizhou,L.Hanlin,M.Hongchang,Z.Wenrong,C.Yunfeng, A124600100005 F.Pieguo,W.Dahai) A124600100006 REFERENCE (J,NIM/A,255,115,1987) -final publ. A124600100007 (J,CST,20,441,1986) on Chinese. - prelim. publ.; A124600100008 same data in table except for 3rd and 5th A124600100009 coeff. at Ed=2.0 MeV A124600100010 INSTITUTE (3CPRAEP) A124600100011 FACILITY (VDG,3CPRAEP) A124600100012 SAMPLE T-Ti target, which was of 0.45, 1.51 and 1.96 mg/cm2 A124600100013 thickness for deuteron energies of 1, 1.5 and 2 MeV A124600100014 respectively A124600100015 MONITOR (1-H-3(D,EL)1-H-3,,DA,,RTH) A124600100016 DETECTOR (TELES,CSICR,SIBAR) Proton recoil. The neutron angular A124600100017 distribution was measured with a proton recoil A124600100018 telescope counter. In this counter protons are A124600100019 scattered out of a polyethylene foil 43 mg/cm3 A124600100020 thick and detected by a CsI crystal a transmission A124600100021 Au-Si surface barrier detector 300 um thick is A124600100022 inserted between foil and crystal. To reduce the A124600100023 background the pulse height spectrum of the CsI A124600100024 crystal is gated by the coincidence pulse of two A124600100025 counters. In this was the background counting rate A124600100026 measured without the polythene foil was only about 3% A124600100027 of the counting rate obtained with the foil in A124600100028 position. At a deuteron energy of 1 MeV the neutrons A124600100029 were monitored by the associated alpha particle A124600100030 method, and at deuteron of 1.5 and 2 MeV by two Au-Si A124600100031 surface barrier detectors. The monitors were mounted A124600100032 12 cm from the target at an angle of 140 degr. A124600100033 ERR-ANALYS (ERR-T) Total error includes: A124600100034 (ERR-1) Uncertainty in geometry A124600100035 (ERR-S) Statistical error in telescope counts A124600100036 (ERR-2) Uncertainty due to choice of limits for A124600100037 proton pesk A124600100038 (ERR-3) Uncertainty in total n-p scattering cr.section A124600100039 (ERR-4) Uncertainty in anisotropy of n-p scattering A124600100040 (ERR-5) Total monitor accuracy A124600100041 (ERR-6) Uncertainty due to flux attenuation and A124600100042 scattering in the target holder A124600100043 HISTORY (19871030C) Compilation produced by Arzamas RFNC-VNIIEFA124600100044 (19990305U)CNPD: corrected 4-dig. year and lower cases.A124600100045 (20210317A) SD: Ref. and ERR-ANALYS added. Corrections A124600100046 in all Subents. A124600100047 ENDBIB 45 0 A124600100048 COMMON 7 6 A124600100049 ERR-1 ERR-S ERR-2 ERR-3 ERR-4 ERR-5 A124600100050 ERR-6 A124600100051 PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT A124600100052 PER-CENT A124600100053 1.2 1.0 0.3 0.7 0.5 1.6A124600100054 1.0 A124600100055 ENDCOMMON 6 0 A124600100056 ENDSUBENT 55 0 A124600199999 SUBENT A1246002 20210317 A097A124600200001 BIB 3 3 A124600200002 REACTION (1-H-3(D,N)2-HE-4,,DA,,LEG/RS0) A124600200003 STATUS (TABLE) Table 1 from Nucl.Instr.Meth.,A255(1987)115 A124600200004 HISTORY (20210317A) SD: SF9=EXP deleted from REACTION code. A124600200005 ENDBIB 3 0 A124600200006 COMMON 1 3 A124600200007 ERR-T A124600200008 PER-CENT A124600200009 2.6 A124600200010 ENDCOMMON 3 0 A124600200011 DATA 3 12 A124600200012 EN NUMBER-CM DATA-CM A124600200013 MEV NO-DIM NO-DIM A124600200014 1. 0. 0.924 A124600200015 1. 1. 0.116 A124600200016 1. 2. -0.040 A124600200017 1.5 0. 0.874 A124600200018 1.5 1. 0.122 A124600200019 1.5 2. 0.004 A124600200020 2.0 0. 0.775 A124600200021 2.0 1. 0.114 A124600200022 2.0 2. 0.061 A124600200023 2.0 3. 0.014 A124600200024 2.0 4. 0.032 A124600200025 2.0 5. 0.003 A124600200026 ENDDATA 14 0 A124600200027 ENDSUBENT 26 0 A124600299999 ENDENTRY 2 0 A124699999999