ENTRY A1461 20200319 A094A146100000001 SUBENT A1461001 20200319 A094A146100100001 BIB 9 19 A146100100002 TITLE The 7Li(p,gamma)8Be* reaction and single-particle A146100100003 levels in 8Be A146100100004 AUTHOR (J.B.Marion,M.Wilson) A146100100005 REFERENCE (J,NP,77,129,1966) A146100100006 (T,WILSON,1965) tables; experim.description A146100100007 (J,PL,14,313,1965) Preliminary accounts of this A146100100008 experiment and A146100100009 (J,PL,14,315,1965) the result's interpretation A146100100010 INSTITUTE (1USAMRY) A146100100011 FACILITY (VDG,1USAMRY) A146100100012 SAMPLE The targets consisted of a thin film of LiF deposited A146100100013 on 0.75 inch diam. x 0.20 inch thick tantalum disks A146100100014 by vacuum evaporation. A146100100015 METHOD (BCINT) A146100100016 ERR-ANALYS (DATA-ERR) No information about source of uncertaintiesA146100100017 HISTORY (19800907C) Compilation Produced by RFNC-VNIIEF Sarov A146100100018 (19990321U)CNPD: corrected 4-dig. year and lower cases.A146100100019 (20200319A) SD: Corrections in all Subents. Digitized A146100100020 data were changed on tabulated from thesis. BIB updatedA146100100021 ENDBIB 19 0 A146100100022 COMMON 1 3 A146100100023 ANG A146100100024 ADEG A146100100025 120.0 A146100100026 ENDCOMMON 3 0 A146100100027 ENDSUBENT 26 0 A146100199999 SUBENT A1461002 20200319 A094A146100200001 BIB 6 21 A146100200002 REACTION (3-LI-7(P,A)2-HE-4,PAR,DA) A146100200003 DETECTOR (MAGSP,SOLST,PLATE) The alpha-particles were momentum A146100200004 analyzed in a 180.degr. double-focusing magnetic A146100200005 spectrometer of 50 cm radius. The plates were made of A146100200006 thin glass, 8 inches by 2 inches, supporting a A146100200007 50 micron thick K-1 or K-2 emulsion composition A146100200008 manufactured by Ilford of England. A146100200009 A solid-state detector was used for some confirmatory A146100200010 measurements as well as for a determination of the A146100200011 alpha0 excitation function for the purpose of A146100200012 normalizing the emulsion data. A146100200013 (SOLST) An independent measurement of the alpha0 A146100200014 excitation curve was made with another solid state A146100200015 detector (but not used in conjunction with the magneticA146100200016 spectrometer). A146100200017 MISC-COL (MISC1) solid state detector used A146100200018 (MISC2) magnetic spectrometer used A146100200019 STATUS (TABLE) Tbl.III from M.Wilson's thesis A146100200020 COMMENT Data are an average from two different methods A146100200021 HISTORY (20200319A) SD: SF5=PAR added; SF9=EXP deleted from A146100200022 REACTION code. ERR-ANALYS deleted. ERR-T -> DATA-ERR. A146100200023 ENDBIB 21 0 A146100200024 COMMON 1 3 A146100200025 E-LVL A146100200026 MEV A146100200027 0.0 A146100200028 ENDCOMMON 3 0 A146100200029 DATA 5 11 A146100200030 EN DATA DATA-ERR MISC1 MISC2 A146100200031 MEV MB/SR MB/SR MB/SR MB/SR A146100200032 0.441 0.216 0.011 0.218 0.208 A146100200033 0.655 0.314 0.018 0.361 A146100200034 0.850 0.440 0.035 0.456 0.422 A146100200035 0.950 0.519 0.045 0.570 A146100200036 1.030 0.595 0.045 0.611 A146100200037 1.050 0.605 0.05 0.54 A146100200038 1.105 0.659 0.05 0.643 A146100200039 1.300 0.90 0.08 0.99 A146100200040 1.500 1.04 0.11 0.95 A146100200041 2.000 1.70 0.2 1.70 A146100200042 2.400 2.9 0.35 2.90 A146100200043 ENDDATA 13 0 A146100200044 ENDSUBENT 43 0 A146100299999 SUBENT A1461003 20200319 A094A146100300001 BIB 4 6 A146100300002 REACTION (3-LI-7(P,G)4-BE-8,PAR,DA) A146100300003 DETECTOR (NAICR) The gamma-ray detector was a 7.65 cm x 7.65 cm A146100300004 NaI crystal A146100300005 STATUS (TABLE) Tbl.III from M.Wilson's thesis A146100300006 HISTORY (20200319A) SD: SF9=EXP deleted from REACTION code. A146100300007 ERR-ANALYS deleted. ERR-T -> DATA-ERR. A146100300008 ENDBIB 6 0 A146100300009 COMMON 1 3 A146100300010 E-LVL A146100300011 MEV A146100300012 16.62 A146100300013 ENDCOMMON 3 0 A146100300014 DATA 4 8 A146100300015 EN DATA DATA-ERR MISC A146100300016 MEV MU-B/SR MU-B/SR NO-DIM A146100300017 0.441 6.43 0.7 2.37E-03 A146100300018 0.655 0.512 0.1 0.13E-03 A146100300019 0.850 1.2 0.14 0.216E-03 A146100300020 0.950 1.29 0.19 0.198E-03 A146100300021 1.030 1.43 0.21 0.190E-03 A146100300022 1.105 1.82 0.36 0.220E-03 A146100300023 1.300 2.17 0.32 0.193E-03 A146100300024 2.400 2.05 0.41 0.056E-03 A146100300025 ENDDATA 10 0 A146100300026 ENDSUBENT 25 0 A146100399999 SUBENT A1461004 20200319 A094A146100400001 BIB 4 6 A146100400002 REACTION (3-LI-7(P,G)4-BE-8,PAR,DA) A146100400003 DETECTOR (NAICR) The gamma-ray detector was a 7.65 cm x 7.65 cm A146100400004 NaI crystal A146100400005 STATUS (CURVE) Fig. 8 from M.Wilson's thesis (same on fig.7 ofA146100400006 Nucl.Phys.,77(1966)129 A146100400007 HISTORY (20200319C) SD A146100400008 ENDBIB 6 0 A146100400009 COMMON 3 3 A146100400010 E-LVL EN-ERR ERR-DIG A146100400011 MEV MEV MU-B/SR A146100400012 16.62 0.001 0.01 A146100400013 ENDCOMMON 3 0 A146100400014 DATA 3 7 A146100400015 EN DATA DATA-ERR A146100400016 MEV MU-B/SR MU-B/SR A146100400017 0.423 0.86 0.20 A146100400018 0.430 2.38 0.31 A146100400019 0.438 5.90 0.45 A146100400020 0.441 6.46 0.61 A146100400021 0.447 4.62 0.45 A146100400022 0.452 2.95 0.41 A146100400023 0.458 1.81 0.30 A146100400024 ENDDATA 9 0 A146100400025 ENDSUBENT 24 0 A146100499999 ENDENTRY 4 0 A146199999999