ENTRY B0012 20011220 0000B001200000001 SUBENT B0012001 20011220 0000B001200100001 BIB 12 28 B001200100002 TITLE Cross Sections and Recoil Properties of Xenon Isotopes B001200100003 Formed in 11.5-GeV Proton Bombardment of U-238 B001200100004 AUTHOR (Y.W.YU, N.T.PORILE, R.WARASILA, O.A.SCHAEFFER) B001200100005 INSTITUTE (1USAPUR) B001200100006 (1USASTB) B001200100007 REFERENCE (J,PR/C,8,1091,1973) B001200100008 MONITOR (13-AL-27(P,N+3P)11-NA-24,M+,SIG,,,EVAL) B001200100009 A Value of 8.6 Mb at 11.5 GeV was Adopted B001200100010 MONIT-REF (B0022003,J.B.CUMMING,J,ARN,13,261,1963) B001200100011 FACILITY (SYNCH,1USABNL) B001200100012 SAMPLE Foil of Natural Uranium, Thickness About 38 Mg/Cm**2 B001200100013 METHOD (ASEP,SITA,INTB,MOSEP) B001200100014 DETECTOR (MAGSP). High Sensitivity Mass Spectrometer B001200100015 ANALYSIS The Measured Cross Sections are Either Cumulative or B001200100016 Partial Cumulative, Because the Precursors of the Xe B001200100017 Isotopes Partly Decay Prior to and During the B001200100018 Xe-Determination. The Correction of the Measured ValuesB001200100019 For the Contribution of the Precursors are done Using B001200100020 Literature Values. In Addition the Cross Sections were B001200100021 Corrected For Secondary Effects and Zero Target B001200100022 Thickness. From the Corrected Values Independent and B001200100023 Cumulative Cross Sections of the Xe-Isotopes and Some B001200100024 Progenitors are Derived. B001200100025 HISTORY (19750204C)Mzla B001200100026 (19940525A) Some Corrections have Been Included by B001200100027 CAJAD B001200100028 (19971210A) Err-Analys is Corrected. Lower Case. B001200100029 (20011010U) Last checking has been done. B001200100030 ENDBIB 28 0 B001200100031 NOCOMMON 0 0 B001200100032 ENDSUBENT 31 0 B001200199999 SUBENT B0012002 20011220 0000B001200200001 BIB 3 6 B001200200002 REACTION (92-U-238(P,F)54-XE-122,CUM,SIG,,,EXP) B001200200003 PART-DET (54-XE-122) B001200200004 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001200200005 Standard Deviation of the Measured Values and theB001200200006 Uncertainty in the Absolute Efficiency of the MassB001200200007 Spectrometer. B001200200008 ENDBIB 6 0 B001200200009 NOCOMMON 0 0 B001200200010 DATA 3 1 B001200200011 EN DATA DATA-ERR B001200200012 GEV MB MB B001200200013 11.5 4.2 0.4 B001200200014 ENDDATA 3 0 B001200200015 ENDSUBENT 14 0 B001200299999 SUBENT B0012003 20011220 0000B001200300001 BIB 3 6 B001200300002 REACTION (92-U-238(P,F)54-XE-124,CUM,SIG,,,EXP) B001200300003 PART-DET (54-XE-124) B001200300004 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001200300005 Standard Deviation of the Measured Values and theB001200300006 Uncertainty in the Absolute Efficiency of the MassB001200300007 Spectrometer. B001200300008 ENDBIB 6 0 B001200300009 NOCOMMON 0 0 B001200300010 DATA 3 1 B001200300011 EN DATA DATA-ERR B001200300012 GEV MB MB B001200300013 11.5 6.9 0.7 B001200300014 ENDDATA 3 0 B001200300015 ENDSUBENT 14 0 B001200399999 SUBENT B0012004 20011220 0000B001200400001 BIB 3 6 B001200400002 REACTION (92-U-238(P,F)54-XE-125,CUM,SIG,,,EXP) B001200400003 PART-DET (54-XE-125) B001200400004 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001200400005 Standard Deviation of the Measured Values and theB001200400006 Uncertainty in the Absolute Efficiency of the MassB001200400007 Spectrometer. B001200400008 ENDBIB 6 0 B001200400009 NOCOMMON 0 0 B001200400010 DATA 3 1 B001200400011 EN DATA DATA-ERR B001200400012 GEV MB MB B001200400013 11.5 7.9 0.9 B001200400014 ENDDATA 3 0 B001200400015 ENDSUBENT 14 0 B001200499999 SUBENT B0012005 20011220 0000B001200500001 BIB 3 6 B001200500002 REACTION (92-U-238(P,F)54-XE-126,CUM,SIG,,,EXP) B001200500003 PART-DET (54-XE-126) B001200500004 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001200500005 Standard Deviation of the Measured Values and theB001200500006 Uncertainty in the Absolute Efficiency of the MassB001200500007 Spectrometer. B001200500008 ENDBIB 6 0 B001200500009 NOCOMMON 0 0 B001200500010 DATA 3 1 B001200500011 EN DATA DATA-ERR B001200500012 GEV MB MB B001200500013 11.5 11.5 1.2 B001200500014 ENDDATA 3 0 B001200500015 ENDSUBENT 14 0 B001200599999 SUBENT B0012006 20011220 0000B001200600001 BIB 3 6 B001200600002 REACTION (92-U-238(P,F)54-XE-127,CUM,SIG,,,EXP) B001200600003 PART-DET (54-XE-127) B001200600004 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001200600005 Standard Deviation of the Measured Values and theB001200600006 Uncertainty in the Absolute Efficiency of the MassB001200600007 Spectrometer. B001200600008 ENDBIB 6 0 B001200600009 NOCOMMON 0 0 B001200600010 DATA 3 1 B001200600011 EN DATA DATA-ERR B001200600012 GEV MB MB B001200600013 11.5 9.5 0.9 B001200600014 ENDDATA 3 0 B001200600015 ENDSUBENT 14 0 B001200699999 SUBENT B0012007 20011220 0000B001200700001 BIB 3 6 B001200700002 REACTION (92-U-238(P,F)54-XE-128,CUM,SIG,,,EXP) B001200700003 PART-DET (54-XE-128) B001200700004 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001200700005 Standard Deviation of the Measured Values and theB001200700006 Uncertainty in the Absolute Efficiency of the MassB001200700007 Spectrometer. B001200700008 ENDBIB 6 0 B001200700009 NOCOMMON 0 0 B001200700010 DATA 3 1 B001200700011 EN DATA DATA-ERR B001200700012 GEV MB MB B001200700013 11.5 13.4 1.3 B001200700014 ENDDATA 3 0 B001200700015 ENDSUBENT 14 0 B001200799999 SUBENT B0012008 20011220 0000B001200800001 BIB 3 6 B001200800002 REACTION (92-U-238(P,F)54-XE-129,CUM,SIG,,,EXP) B001200800003 PART-DET (54-XE-129) B001200800004 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001200800005 Standard Deviation of the Measured Values and theB001200800006 Uncertainty in the Absolute Efficiency of the MassB001200800007 Spectrometer. B001200800008 ENDBIB 6 0 B001200800009 NOCOMMON 0 0 B001200800010 DATA 3 1 B001200800011 EN DATA DATA-ERR B001200800012 GEV MB MB B001200800013 11.5 11.2 1.1 B001200800014 ENDDATA 3 0 B001200800015 ENDSUBENT 14 0 B001200899999 SUBENT B0012009 20011220 0000B001200900001 BIB 3 6 B001200900002 REACTION (92-U-238(P,F)54-XE-130,CUM,SIG,,,EXP) B001200900003 PART-DET (54-XE-130) B001200900004 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001200900005 Standard Deviation of the Measured Values and theB001200900006 Uncertainty in the Absolute Efficiency of the MassB001200900007 Spectrometer. B001200900008 ENDBIB 6 0 B001200900009 NOCOMMON 0 0 B001200900010 DATA 3 1 B001200900011 EN DATA DATA-ERR B001200900012 GEV MB MB B001200900013 11.5 7.4 0.7 B001200900014 ENDDATA 3 0 B001200900015 ENDSUBENT 14 0 B001200999999 SUBENT B0012010 20011220 0000B001201000001 BIB 3 6 B001201000002 REACTION (92-U-238(P,F)54-XE-131,CUM,SIG,,,EXP) B001201000003 PART-DET (54-XE-131) B001201000004 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001201000005 Standard Deviation of the Measured Values and theB001201000006 Uncertainty in the Absolute Efficiency of the MassB001201000007 Spectrometer. B001201000008 ENDBIB 6 0 B001201000009 NOCOMMON 0 0 B001201000010 DATA 3 1 B001201000011 EN DATA DATA-ERR B001201000012 GEV MB MB B001201000013 11.5 23.3 2.3 B001201000014 ENDDATA 3 0 B001201000015 ENDSUBENT 14 0 B001201099999 SUBENT B0012011 20011220 0000B001201100001 BIB 4 11 B001201100002 REACTION (92-U-238(P,F)54-XE-132,CUM,SIG,,,EXP) B001201100003 PART-DET (54-XE-132) B001201100004 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001201100005 Standard Deviation of the Measured Values and theB001201100006 Uncertainty in the Absolute Efficiency of the MassB001201100007 Spectrometer. B001201100008 COMMENT The Present Value is Some 30 % Lower Than That B001201100009 Reported by J.Hudis Et Al., Phys.Rev.,C1,2019(70). ThisB001201100010 Difference Merely Reflects the Fact That No Correction B001201100011 For Secondary Production was Applied in the Earlier B001201100012 Work. B001201100013 ENDBIB 11 0 B001201100014 NOCOMMON 0 0 B001201100015 DATA 3 1 B001201100016 EN DATA DATA-ERR B001201100017 GEV MB MB B001201100018 11.5 13.7 1.4 B001201100019 ENDDATA 3 0 B001201100020 ENDSUBENT 19 0 B001201199999 SUBENT B0012012 20011220 0000B001201200001 BIB 4 12 B001201200002 REACTION (92-U-238(P,F)54-XE-133,CUM,SIG,,,EXP) B001201200003 PART-DET (54-XE-133) B001201200004 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001201200005 Standard Deviation of the Measured Values and theB001201200006 Uncertainty in the Absolute Efficiency of the MassB001201200007 Spectrometer. B001201200008 COMMENT The Value is by More Than a Factor of 2 Lower Than ThatB001201200009 Reported by J.Hudis Et Al., Phys.Rev.,C1,2019(70). ThisB001201200010 Difference Partly Reflects the Fact That No Correction B001201200011 For Secondary Production was Applied in the Earlier B001201200012 Work. The Authors Assume, That the Earlier Value is TooB001201200013 High. B001201200014 ENDBIB 12 0 B001201200015 NOCOMMON 0 0 B001201200016 DATA 3 1 B001201200017 EN DATA DATA-ERR B001201200018 GEV MB MB B001201200019 11.5 11.4 1.2 B001201200020 ENDDATA 3 0 B001201200021 ENDSUBENT 20 0 B001201299999 SUBENT B0012013 20011220 0000B001201300001 BIB 4 11 B001201300002 REACTION (92-U-238(P,F)54-XE-134,CUM,SIG,,,EXP) B001201300003 PART-DET (54-XE-134) B001201300004 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001201300005 Standard Deviation of the Measured Values and theB001201300006 Uncertainty in the Absolute Efficiency of the MassB001201300007 Spectrometer. B001201300008 COMMENT The Present Value is Some 30 % Lower Than That B001201300009 Reported by J.Hudis Et Al. Phys.Rev.,C1,2019(70). This B001201300010 Difference Merely Reflects the Fact That No Correction B001201300011 For Secondary Production was Applied in the Earlier B001201300012 Work. B001201300013 ENDBIB 11 0 B001201300014 NOCOMMON 0 0 B001201300015 DATA 3 1 B001201300016 EN DATA DATA-ERR B001201300017 GEV MB MB B001201300018 11.5 10.7 1. B001201300019 ENDDATA 3 0 B001201300020 ENDSUBENT 19 0 B001201399999 SUBENT B0012014 20011220 0000B001201400001 BIB 3 6 B001201400002 REACTION (92-U-238(P,F)54-XE-135,CUM,SIG,,,EXP) B001201400003 PART-DET (54-XE-135) B001201400004 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001201400005 Standard Deviation of the Measured Values and theB001201400006 Uncertainty in the Absolute Efficiency of the MassB001201400007 Spectrometer. B001201400008 ENDBIB 6 0 B001201400009 NOCOMMON 0 0 B001201400010 DATA 3 1 B001201400011 EN DATA DATA-ERR B001201400012 GEV MB MB B001201400013 11.5 8.4 1.2 B001201400014 ENDDATA 3 0 B001201400015 ENDSUBENT 14 0 B001201499999 SUBENT B0012015 20011220 0000B001201500001 BIB 4 11 B001201500002 REACTION (92-U-238(P,F)54-XE-136,CUM,SIG,,,EXP) B001201500003 PART-DET (54-XE-136) B001201500004 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001201500005 Standard Deviation of the Measured Values and theB001201500006 Uncertainty in the Absolute Efficiency of the MassB001201500007 Spectrometer. B001201500008 COMMENT The Present Value is Some 30 % Lower Than That B001201500009 Reported by J.Hudis Et Al., Phys.Rev.,C1,2019(70). ThisB001201500010 Difference Merely Reflects the Fact That No Correction B001201500011 For Secondary Production was Applied in the Earlier B001201500012 Work. B001201500013 ENDBIB 11 0 B001201500014 NOCOMMON 0 0 B001201500015 DATA 3 1 B001201500016 EN DATA DATA-ERR B001201500017 GEV MB MB B001201500018 11.5 8. 0.8 B001201500019 ENDDATA 3 0 B001201500020 ENDSUBENT 19 0 B001201599999 SUBENT B0012016 20011220 0000B001201600001 BIB 4 9 B001201600002 REACTION (92-U-238(P,F)54-XE-122,IND,SIG,,,EXP) B001201600003 PART-DET (54-XE-122) B001201600004 ADD-RES (RANGE).Isotopic Yield Distribution B001201600005 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001201600006 Standard Deviation of the Measured Values and the B001201600007 Uncertainty of the Correction For Precursor B001201600008 Contribution. The Value Does not Include the 10% B001201600009 Systematic Error in the Absolute Efficiency of the MassB001201600010 Spectrometer. B001201600011 ENDBIB 9 0 B001201600012 NOCOMMON 0 0 B001201600013 DATA 3 1 B001201600014 EN DATA DATA-ERR B001201600015 GEV MB MB B001201600016 11.5 2.16 0.22 B001201600017 ENDDATA 3 0 B001201600018 ENDSUBENT 17 0 B001201699999 SUBENT B0012017 20011220 0000B001201700001 BIB 4 9 B001201700002 REACTION (92-U-238(P,F)54-XE-124,IND,SIG,,,EXP) B001201700003 PART-DET (54-XE-124) B001201700004 ADD-RES (RANGE).Isotopic Yield Distribution B001201700005 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001201700006 Standard Deviation of the Measured Values and the B001201700007 Uncertainty of the Correction For Precursor B001201700008 Contribution. The Value Does not Include the 10% B001201700009 Systematic Error in the Absolute Efficiency of the MassB001201700010 Spectrometer. B001201700011 ENDBIB 9 0 B001201700012 NOCOMMON 0 0 B001201700013 DATA 3 1 B001201700014 EN DATA DATA-ERR B001201700015 GEV MB MB B001201700016 11.5 3. 0.2 B001201700017 ENDDATA 3 0 B001201700018 ENDSUBENT 17 0 B001201799999 SUBENT B0012018 20011220 0000B001201800001 BIB 4 9 B001201800002 REACTION (92-U-238(P,F)54-XE-125,IND,SIG,,,EXP) B001201800003 PART-DET (54-XE-125) B001201800004 ADD-RES (RANGE).Isotopic Yield Distribution B001201800005 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001201800006 Standard Deviation of the Measured Values and the B001201800007 Uncertainty of the Correction For Precursor B001201800008 Contribution. The Value Does not Include the 10% B001201800009 Systematic Error in the Absolute Efficiency of the MassB001201800010 Spectrometer. B001201800011 ENDBIB 9 0 B001201800012 NOCOMMON 0 0 B001201800013 DATA 3 1 B001201800014 EN DATA DATA-ERR B001201800015 GEV MB MB B001201800016 11.5 3.1 0.69 B001201800017 ENDDATA 3 0 B001201800018 ENDSUBENT 17 0 B001201899999 SUBENT B0012019 20011220 0000B001201900001 BIB 4 9 B001201900002 REACTION (92-U-238(P,F)54-XE-126,IND,SIG,,,EXP) B001201900003 PART-DET (54-XE-126) B001201900004 ADD-RES (RANGE).Isotopic Yield Distribution B001201900005 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001201900006 Standard Deviation of the Measured Values and the B001201900007 Uncertainty of the Correction For Precursor B001201900008 Contribution. The Value Does not Include the 10% B001201900009 Systematic Error in the Absolute Efficiency of the MassB001201900010 Spectrometer. B001201900011 ENDBIB 9 0 B001201900012 NOCOMMON 0 0 B001201900013 DATA 3 1 B001201900014 EN DATA DATA-ERR B001201900015 GEV MB MB B001201900016 11.5 2.86 0.58 B001201900017 ENDDATA 3 0 B001201900018 ENDSUBENT 17 0 B001201999999 SUBENT B0012020 20011220 0000B001202000001 BIB 5 14 B001202000002 REACTION (92-U-238(P,F)54-XE-127,IND,SIG,,,EXP) B001202000003 PART-DET (54-XE-127) B001202000004 ADD-RES (RANGE).Isotopic Yield Distribution B001202000005 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001202000006 Standard Deviation of the Measured Values and the B001202000007 Uncertainty of the Correction For Precursor B001202000008 Contribution. The Value Does not Include the 10% B001202000009 Systematic Error in the Absolute Efficiency of the MassB001202000010 Spectrometer. B001202000011 COMMENT With a Simpler Correction Procedure,Taking Into AccountB001202000012 The Independent Xe-Yield, the Cumulative Parent Yield, B001202000013 The Measured Yield, the Irradiation Time and the Xe- B001202000014 Separation Time, a Value of 2.70(+-2.70)Mb was B001202000015 Obtained For the Independent Yield of the Xe-Isotope. B001202000016 ENDBIB 14 0 B001202000017 NOCOMMON 0 0 B001202000018 DATA 3 1 B001202000019 EN DATA DATA-ERR B001202000020 GEV MB MB B001202000021 11.5 2.12 0.63 B001202000022 ENDDATA 3 0 B001202000023 ENDSUBENT 22 0 B001202099999 SUBENT B0012021 20011220 0000B001202100001 BIB 4 9 B001202100002 REACTION (92-U-238(P,F)54-XE-128,IND,SIG,,,EXP) B001202100003 PART-DET (54-XE-128) B001202100004 ADD-RES (RANGE).Isotopic Yield Distribution B001202100005 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001202100006 Standard Deviation of the Measured Values and the B001202100007 Uncertainty of the Correction For Precursor B001202100008 Contribution. The Value Does not Include the 10% B001202100009 Systematic Error in the Absolute Efficiency of the MassB001202100010 Spectrometer. B001202100011 ENDBIB 9 0 B001202100012 NOCOMMON 0 0 B001202100013 DATA 3 1 B001202100014 EN DATA DATA-ERR B001202100015 GEV MB MB B001202100016 11.5 2.22 0.64 B001202100017 ENDDATA 3 0 B001202100018 ENDSUBENT 17 0 B001202199999 SUBENT B0012022 20011220 0000B001202200001 BIB 5 14 B001202200002 REACTION (92-U-238(P,F)54-XE-129,IND,SIG,,,EXP) B001202200003 PART-DET (54-XE-129) B001202200004 ADD-RES (RANGE).Isotopic Yield Distribution B001202200005 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001202200006 Standard Deviation of the Measured Values and the B001202200007 Uncertainty of the Correction For Precursor B001202200008 Contribution. The Value Does not Include the 10% B001202200009 Systematic Error in the Absolute Efficiency of the MassB001202200010 Spectrometer. B001202200011 COMMENT With a Simpler Correction Procedure,Taking Into AccountB001202200012 The Independent Xe-Yield, the Cumulative Parent Yield, B001202200013 The Measured Yield, the Irradiation Time and the Xe- B001202200014 Separation Time, a Value of 2.59(+-0.15)Mb was B001202200015 Obtained For the Independent Yield of the Xe-Isotope. B001202200016 ENDBIB 14 0 B001202200017 NOCOMMON 0 0 B001202200018 DATA 3 1 B001202200019 EN DATA DATA-ERR B001202200020 GEV MB MB B001202200021 11.5 2.47 0.31 B001202200022 ENDDATA 3 0 B001202200023 ENDSUBENT 22 0 B001202299999 SUBENT B0012023 20011220 0000B001202300001 BIB 4 9 B001202300002 REACTION (92-U-238(P,F)54-XE-130,IND,SIG,,,EXP) B001202300003 PART-DET (54-XE-130) B001202300004 ADD-RES (RANGE).Isotopic Yield Distribution B001202300005 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001202300006 Standard Deviation of the Measured Values and the B001202300007 Uncertainty of the Correction For Precursor B001202300008 Contribution. The Value Does not Include the 10% B001202300009 Systematic Error in the Absolute Efficiency of the MassB001202300010 Spectrometer. B001202300011 ENDBIB 9 0 B001202300012 NOCOMMON 0 0 B001202300013 DATA 3 1 B001202300014 EN DATA DATA-ERR B001202300015 GEV MB MB B001202300016 11.5 2.74 0.34 B001202300017 ENDDATA 3 0 B001202300018 ENDSUBENT 17 0 B001202399999 SUBENT B0012024 20011220 0000B001202400001 BIB 4 9 B001202400002 REACTION (92-U-238(P,F)54-XE-131,IND,SIG,,,EXP) B001202400003 PART-DET (54-XE-131) B001202400004 ADD-RES (RANGE).Isotopic Yield Distribution B001202400005 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001202400006 Standard Deviation of the Measured Values and the B001202400007 Uncertainty of the Correction For Precursor B001202400008 Contribution. The Value Does not Include the 10% B001202400009 Systematic Error in the Absolute Efficiency of the MassB001202400010 Spectrometer. B001202400011 ENDBIB 9 0 B001202400012 NOCOMMON 0 0 B001202400013 DATA 3 1 B001202400014 EN DATA DATA-ERR B001202400015 GEV MB MB B001202400016 11.5 2.48 0.3 B001202400017 ENDDATA 3 0 B001202400018 ENDSUBENT 17 0 B001202499999 SUBENT B0012025 20011220 0000B001202500001 BIB 4 9 B001202500002 REACTION (92-U-238(P,F)54-XE-132,IND,SIG,,,EXP) B001202500003 PART-DET (54-XE-132) B001202500004 ADD-RES (RANGE).Isotopic Yield Distribution B001202500005 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001202500006 Standard Deviation of the Measured Values and the B001202500007 Uncertainty of the Correction For Precursor B001202500008 Contribution. The Value Does not Include the 10% B001202500009 Systematic Error in the Absolute Efficiency of the MassB001202500010 Spectrometer. B001202500011 ENDBIB 9 0 B001202500012 NOCOMMON 0 0 B001202500013 DATA 3 1 B001202500014 EN DATA DATA-ERR B001202500015 GEV MB MB B001202500016 11.5 2.24 0.5 B001202500017 ENDDATA 3 0 B001202500018 ENDSUBENT 17 0 B001202599999 SUBENT B0012026 20011220 0000B001202600001 BIB 5 14 B001202600002 REACTION (92-U-238(P,F)54-XE-133,IND,SIG,,,EXP) B001202600003 PART-DET (54-XE-133) B001202600004 ADD-RES (RANGE).Isotopic Yield Distribution B001202600005 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001202600006 Standard Deviation of the Measured Values and the B001202600007 Uncertainty of the Correction For Precursor B001202600008 Contribution. The Value Does not Include the 10% B001202600009 Systematic Error in the Absolute Efficiency of the MassB001202600010 Spectrometer. B001202600011 COMMENT With a Simpler Correction Procedure,Taking Into AccountB001202600012 The Independent Xe-Yield, the Cumulative Parent Yield, B001202600013 The Measured Yield, the Irradiation Time and the Xe- B001202600014 Separation Time, a Value of 2.60(+-1.30)Mb was B001202600015 Obtained For the Independent Yield of the Xe-Isotope. B001202600016 ENDBIB 14 0 B001202600017 NOCOMMON 0 0 B001202600018 DATA 3 1 B001202600019 EN DATA DATA-ERR B001202600020 GEV MB MB B001202600021 11.5 2.7 0.47 B001202600022 ENDDATA 3 0 B001202600023 ENDSUBENT 22 0 B001202699999 SUBENT B0012027 20011220 0000B001202700001 BIB 4 9 B001202700002 REACTION (92-U-238(P,F)54-XE-134,IND,SIG,,,EXP) B001202700003 PART-DET (54-XE-134) B001202700004 ADD-RES (RANGE).Isotopic Yield Distribution B001202700005 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001202700006 Standard Deviation of the Measured Values and the B001202700007 Uncertainty of the Correction For Precursor B001202700008 Contribution. The Value Does not Include the 10% B001202700009 Systematic Error in the Absolute Efficiency of the MassB001202700010 Spectrometer. B001202700011 ENDBIB 9 0 B001202700012 NOCOMMON 0 0 B001202700013 DATA 3 1 B001202700014 EN DATA DATA-ERR B001202700015 GEV MB MB B001202700016 11.5 4.2 0.67 B001202700017 ENDDATA 3 0 B001202700018 ENDSUBENT 17 0 B001202799999 SUBENT B0012028 20011220 0000B001202800001 BIB 4 9 B001202800002 REACTION (92-U-238(P,F)54-XE-135,IND,SIG,,,EXP) B001202800003 PART-DET (54-XE-135) B001202800004 ADD-RES (RANGE).Isotopic Yield Distribution B001202800005 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001202800006 Standard Deviation of the Measured Values and the B001202800007 Uncertainty of the Correction For Precursor B001202800008 Contribution. The Value Does not Include the 10% B001202800009 Systematic Error in the Absolute Efficiency of the MassB001202800010 Spectrometer. B001202800011 ENDBIB 9 0 B001202800012 NOCOMMON 0 0 B001202800013 DATA 3 1 B001202800014 EN DATA DATA-ERR B001202800015 GEV MB MB B001202800016 11.5 4.51 0.88 B001202800017 ENDDATA 3 0 B001202800018 ENDSUBENT 17 0 B001202899999 SUBENT B0012029 20011220 0000B001202900001 BIB 4 9 B001202900002 REACTION (92-U-238(P,F)54-XE-136,IND,SIG,,,EXP) B001202900003 PART-DET (54-XE-136) B001202900004 ADD-RES (RANGE).Isotopic Yield Distribution B001202900005 ERR-ANALYS (DATA-ERR) The Error Given Includes the Experimental B001202900006 Standard Deviation of the Measured Values and the B001202900007 Uncertainty of the Correction For Precursor B001202900008 Contribution. The Value Does not Include the 10% B001202900009 Systematic Error in the Absolute Efficiency of the MassB001202900010 Spectrometer. B001202900011 ENDBIB 9 0 B001202900012 NOCOMMON 0 0 B001202900013 DATA 3 1 B001202900014 EN DATA DATA-ERR B001202900015 GEV MB MB B001202900016 11.5 4.84 0.69 B001202900017 ENDDATA 3 0 B001202900018 ENDSUBENT 17 0 B001202999999 SUBENT B0012030 20011220 0000B001203000001 BIB 3 6 B001203000002 REACTION (92-U-238(P,F)53-I-126,IND,SIG,,,EXP) B001203000003 PART-DET (54-XE-126) B001203000004 ERR-ANALYS (DATA-ERR) It is not Stated, If the Error Includes the B001203000005 Uncertainty of the Absolute Efficiency of the MassB001203000006 Spectrometer -About 10% or If the Experimental StandardB001203000007 Deviation is Given Only (COMMENT BY THE COMPILER). B001203000008 ENDBIB 6 0 B001203000009 NOCOMMON 0 0 B001203000010 DATA 3 1 B001203000011 EN DATA DATA-ERR B001203000012 GEV MB MB B001203000013 11.5 4.3 1.6 B001203000014 ENDDATA 3 0 B001203000015 ENDSUBENT 14 0 B001203099999 SUBENT B0012031 20011220 0000B001203100001 BIB 3 6 B001203100002 REACTION (92-U-238(P,F)53-I-130,IND,SIG,,,EXP) B001203100003 PART-DET (54-XE-130) B001203100004 ERR-ANALYS (DATA-ERR) It is not Stated, If the Error Includes the B001203100005 Uncertainty of the Absolute Efficiency of the MassB001203100006 Spectrometer -About 10% or If the Experimental StandardB001203100007 Deviation is Given Only (COMMENT BY THE COMPILER). B001203100008 ENDBIB 6 0 B001203100009 NOCOMMON 0 0 B001203100010 DATA 3 1 B001203100011 EN DATA DATA-ERR B001203100012 GEV MB MB B001203100013 11.5 2.7 1.3 B001203100014 ENDDATA 3 0 B001203100015 ENDSUBENT 14 0 B001203199999 SUBENT B0012032 20011220 0000B001203200001 BIB 3 6 B001203200002 REACTION (92-U-238(P,F)53-I-133,CUM,SIG,,,EXP) B001203200003 PART-DET (54-XE-133) B001203200004 ERR-ANALYS (DATA-ERR) It is not Stated, If the Error Includes the B001203200005 Uncertainty of the Absolute Efficiency of the MassB001203200006 Spectrometer -About 10% or If the Experimental StandardB001203200007 Deviation is Given Only (COMMENT BY THE COMPILER). B001203200008 ENDBIB 6 0 B001203200009 NOCOMMON 0 0 B001203200010 DATA 3 1 B001203200011 EN DATA DATA-ERR B001203200012 GEV MB MB B001203200013 11.5 10. 2.7 B001203200014 ENDDATA 3 0 B001203200015 ENDSUBENT 14 0 B001203299999 SUBENT B0012033 20011220 0000B001203300001 BIB 3 6 B001203300002 REACTION (92-U-238(P,F)55-CS-127,CUM,SIG,,,EXP) B001203300003 PART-DET (54-XE-127) B001203300004 ERR-ANALYS (DATA-ERR) It is not Stated, If the Error Includes the B001203300005 Uncertainty of the Absolute Efficiency of the MassB001203300006 Spectrometer -About 10% or If the Experimental StandardB001203300007 Deviation is Given Only (COMMENT BY THE COMPILER). B001203300008 ENDBIB 6 0 B001203300009 NOCOMMON 0 0 B001203300010 DATA 3 1 B001203300011 EN DATA DATA-ERR B001203300012 GEV MB MB B001203300013 11.5 6.9 5. B001203300014 ENDDATA 3 0 B001203300015 ENDSUBENT 14 0 B001203399999 SUBENT B0012034 20011220 0000B001203400001 BIB 3 6 B001203400002 REACTION (92-U-238(P,F)55-CS-129,CUM,SIG,,,EXP) B001203400003 PART-DET (54-XE-129) B001203400004 ERR-ANALYS (DATA-ERR) It is not Stated, If the Error Includes the B001203400005 Uncertainty of the Absolute Efficiency of the MassB001203400006 Spectrometer -About 10% or If the Experimental StandardB001203400007 Deviation is Given Only (COMMENT BY THE COMPILER). B001203400008 ENDBIB 6 0 B001203400009 NOCOMMON 0 0 B001203400010 DATA 3 1 B001203400011 EN DATA DATA-ERR B001203400012 GEV MB MB B001203400013 11.5 8.5 0.4 B001203400014 ENDDATA 3 0 B001203400015 ENDSUBENT 14 0 B001203499999 SUBENT B0012035 20011220 0000B001203500001 BIB 3 6 B001203500002 REACTION (92-U-238(P,F)56-BA-128,CUM,SIG,,,EXP) B001203500003 PART-DET (54-XE-128) B001203500004 ERR-ANALYS (DATA-ERR) It is not Stated, If the Error Includes the B001203500005 Uncertainty of the Absolute Efficiency of the MassB001203500006 Spectrometer -About 10% or If the Experimental StandardB001203500007 Deviation is Given Only (COMMENT BY THE COMPILER). B001203500008 ENDBIB 6 0 B001203500009 NOCOMMON 0 0 B001203500010 DATA 3 1 B001203500011 EN DATA DATA-ERR B001203500012 GEV MB MB B001203500013 11.5 5.9 1.4 B001203500014 ENDDATA 3 0 B001203500015 ENDSUBENT 14 0 B001203599999 ENDENTRY 35 0 B001299999999