ENTRY B0013 20011220 0000B001300000001 SUBENT B0013001 20011220 0000B001300100001 BIB 9 18 B001300100002 TITLE Determination De L'Intensite D'Un Faisceau De Deutons B001300100003 Extrait D'Un Synchrotron Et Mesure Des Sections B001300100004 Efficaces Des Reactions C-12(D,P2N)C-11 Et B001300100005 Al-27(D,3P2N)Na-24 a 2.33 GeV B001300100006 AUTHOR (J.BANAIGS, J.BERGER, J.DUFLO, L.GOLDZAHL, O.HARFF, B001300100007 M.COTTEREAU, F.LEFEBVRES, H.QUECHON, P.TARDY-JOUBERT) B001300100008 INSTITUTE (2FR SAC) B001300100009 REFERENCE (J,NIM,95,307,1971) B001300100010 FACILITY (SYNCH,2FR SAC) Synchrotron Saturne in Saclay. B001300100011 METHOD (SITA,EXTB) B001300100012 DETECTOR (GEMUC) B001300100013 ERR-ANALYS (DATA-ERR) The Uncertainty of the Monitor Cross SectionB001300100014 And the Counting Statistic was Taken Into Account. B001300100015 HISTORY (19760430C)Pfmz B001300100016 (19940603A) Some Corrections have Been Included by B001300100017 CAJAD B001300100018 (19971210A) Lower Case. Bib Section is Corrected. B001300100019 (20011010U) Last checking has been done. B001300100020 ENDBIB 18 0 B001300100021 NOCOMMON 0 0 B001300100022 ENDSUBENT 21 0 B001300199999 SUBENT B0013002 20011220 0000B001300200001 BIB 6 10 B001300200002 REACTION (6-C-12(D,2N+P)6-C-11,,SIG,,,EXP) B001300200003 SAMPLE Graphite Foil of Nuclear Purity, Thickness 5 mm B001300200004 MONITOR (6-C-12(P,X)6-C-11,,SIG,,,EVAL) B001300200005 A Value of 28+-1.4 Mb at 1.16 GeV is Used. The B001300200006 Measurement is Based on the Fact That a Proton Beam andB001300200007 A Deuteron Beam of the Same Velocity Produce the Same B001300200008 Cerenkov Light. B001300200009 MONIT-REF (B0022002,J.B.CUMMING,J,ARN,13,261,1963) B001300200010 RAD-DET (6-C-11,B+) B001300200011 DECAY-DATA (6-C-11,20.4MIN,B+,970.,1.0) B001300200012 ENDBIB 10 0 B001300200013 NOCOMMON 0 0 B001300200014 DATA 3 1 B001300200015 EN DATA DATA-ERR B001300200016 GEV MB MB B001300200017 2.33 41.7 2.9 B001300200018 ENDDATA 3 0 B001300200019 ENDSUBENT 18 0 B001300299999 SUBENT B0013003 20011220 0000B001300300001 BIB 6 12 B001300300002 REACTION (13-AL-27(D,X)11-NA-24,,SIG,,,EXP) B001300300003 SAMPLE Aluminium Foil, Purity 99.99 %, Thickness 1.5 mm. B001300300004 MONITOR (13-AL-27(P,X)11-NA-24,,SIG,,,EVAL) B001300300005 A Value of 10.2+-0.7 Mb at 1.16 GeV is Used. The B001300300006 Measurement is Based on the Fact That a Proton Beam andB001300300007 A Deuteron Beam of the Same Velocity Produce the Same B001300300008 Cerenkov Light. B001300300009 MONIT-REF (B0022003,J.B.CUMMING,J,ARN,13,261,1963) B001300300010 RAD-DET (11-NA-24-G,B-) B001300300011 DECAY-DATA (11-NA-24-G,15.0HR,B-,1390.,1.0) B001300300012 (11-NA-24-M,2.E-2SEC) ~100 % Isomeric Transition; B001300300013 Comment by the Compiler. B001300300014 ENDBIB 12 0 B001300300015 NOCOMMON 0 0 B001300300016 DATA 3 1 B001300300017 EN DATA DATA-ERR B001300300018 GEV MB MB B001300300019 2.33 15.25 1.5 B001300300020 ENDDATA 3 0 B001300300021 ENDSUBENT 20 0 B001300399999 ENDENTRY 3 0 B001399999999