ENTRY B0058 20011220 0000B005800000001 SUBENT B0058001 20011220 0000B005800100001 BIB 10 30 B005800100002 TITLE Excitation Functions of (P,N) And (A,N) Reactions B005800100003 On Ni, Cu and Zn B005800100004 AUTHOR (M.HILLE, P.HILLE, M.UHL, W.WEISZ) B005800100005 INSTITUTE (2GERMUN) B005800100006 Physik-Department E14 B005800100007 (2AUSIRK) B005800100008 REFERENCE (J,NP/A,198,625,1972) B005800100009 FACILITY (VDGT,2GERMUN) B005800100010 METHOD (EXTB,STTA,EDEG,BCINT) B005800100011 The Energies in the Foil were Calculated According B005800100012 To J.B.Marion Et Al., Nuclear Reaction Analysis, P.14, B005800100013 North-Holland, Amsterdam (1968). B005800100014 Incident Energies For Protons 16 MeV, For Alpha- B005800100015 Particles 24 MeV. B005800100016 CORRECTION Corrections were Applied For the Summing of Coincident B005800100017 Gamma-Ray Pulses in the Detector, Absorption in the B005800100018 Sources,and Differing Source-Detector Distances For B005800100019 Activated Foils and Standard Sources Used For Cali- B005800100020 Bration,Respectively. Dead-Time Losses of the B005800100021 Multichannel Analyser were Kept Below 30%. B005800100022 Recoil-Losses During the Irradiations were Estimated B005800100023 To be Negligible. B005800100024 DETECTOR (GELI) B005800100025 ADD-RES (COMP) B005800100026 HISTORY (19770128C)Lakw B005800100027 (19940630A) Some Corrections have Been Included by B005800100028 CAJAD B005800100029 (19971123A) Reaction Lines and Err-Analys are B005800100030 Corrected. B005800100031 (20011010U) Last checking has been done. B005800100032 ENDBIB 30 0 B005800100033 NOCOMMON 0 0 B005800100034 ENDSUBENT 33 0 B005800199999 SUBENT B0058002 20011220 0000B005800200001 BIB 6 21 B005800200002 REACTION (29-CU-63(P,N)30-ZN-63,,SIG,,,EXP) B005800200003 RAD-DET (30-ZN-63,DG) B005800200004 DECAY-DATA (30-ZN-63,38.6MIN,DG,670.,0.101) B005800200005 SAMPLE Foils of Natural Cu, Purity Better Than 99.8%, B005800200006 Thickness Approximately 10 Micrometer, Interspersed B005800200007 With Al-Foils For Energy Degradation. B005800200008 ERR-ANALYS (ERR-T) The Accuracy of the Cross Sections is About 6%,B005800200009 Including Uncertainties in Particle Energies (3%) In B005800200010 The Last Foils of the Stacks,Negligible at the B005800200011 Higher Energies, Calibration of the Geli-Detector (3%),B005800200012 Statistical Errors (<1%), Photopeak-Analysis (3%), B005800200013 Foil Thickness (3%) Beam Current Integration (2%), and B005800200014 Half-Lives (1 TO 3%). All Errors Mean 3 Standard B005800200015 Deviations. An Additional Error Due to the UncertaintyB005800200016 Of the Gamma Ray Abundance of About 10% Must be B005800200017 Included. B005800200018 REL-REF (C,B0057002,R.COLLE+,J,PR/C,9,1819,1974) B005800200019 According to Colle Et Al. The Cross Sections Given B005800200020 Have to be Multiplied with a Conversion Factor of B005800200021 1.192 Which Takes Into Account a Change of the 669.6 B005800200022 KeV Gamma-Ray Intensity from 10.1 to 8.47%. B005800200023 ENDBIB 21 0 B005800200024 NOCOMMON 0 0 B005800200025 DATA 3 8 B005800200026 EN DATA ERR-T B005800200027 MEV MB MB B005800200028 8.7 348. B005800200029 9.9 432. B005800200030 11. 475. B005800200031 12. 467. B005800200032 13.1 507. 34. B005800200033 14.1 380. B005800200034 14.9 320. B005800200035 15.8 247. B005800200036 ENDDATA 10 0 B005800200037 ENDSUBENT 36 0 B005800299999 SUBENT B0058003 20011220 0000B005800300001 BIB 5 16 B005800300002 REACTION (30-ZN-66(P,N)31-GA-66,,SIG,,,EXP) B005800300003 RAD-DET (31-GA-66,DG) B005800300004 DECAY-DATA (31-GA-66,9.4HR,DG,1039.,0.39) B005800300005 SAMPLE Foils of Natural Zn, Purity Better Than 99.8%, B005800300006 Thickness Approximately 10 Micrometer, Interspersed B005800300007 With Al-Foils For Energy Degradation. B005800300008 ERR-ANALYS (ERR-T) The Accuracy of the Cross Sections is About 6%,B005800300009 Including Uncertainties in Particle Energies (3% IN THEB005800300010 LAST FOILS OF THE STACKS, NEGLIGIBLE AT THE B005800300011 HIGHER ENERGIES), Calibration of the Geli-Detector (3%)B005800300012 , Statistical Errors (<1%), Photopeak-Analysis (3%), B005800300013 Foil Thickness (3%), Beam Current Integration (2%), andB005800300014 Half-Lives (1 TO 3%). All Errors Mean 3 Standard B005800300015 Deviations. An Additional Error Due to the UncertaintyB005800300016 Of the Gamma Ray Abundance is Mentioned But not B005800300017 Specified. B005800300018 ENDBIB 16 0 B005800300019 NOCOMMON 0 0 B005800300020 DATA 3 8 B005800300021 EN DATA ERR-T B005800300022 MEV MB MB B005800300023 9.5 551. B005800300024 10.6 599. B005800300025 11.6 672. B005800300026 12.6 661. 36. B005800300027 13.4 680. B005800300028 14.3 585. B005800300029 15.1 490. B005800300030 15.9 396. B005800300031 ENDDATA 10 0 B005800300032 ENDSUBENT 31 0 B005800399999 SUBENT B0058004 20011220 0000B005800400001 BIB 5 16 B005800400002 REACTION (30-ZN-68(P,N)31-GA-68,,SIG,,,EXP) B005800400003 RAD-DET (31-GA-68,DG) B005800400004 DECAY-DATA (31-GA-68,68.3MIN,DG,1077.,0.032) B005800400005 SAMPLE Foils of Natural Zn, Purity Better Than 99.8%, B005800400006 Thickness Approximately 10 Micrometer, Interspersed B005800400007 With Al-Foils For Energy Degradation. B005800400008 ERR-ANALYS (ERR-T) The Accuracy of the Cross Sections is About 6%,B005800400009 Including Uncertainties in Particle Energies (3% IN THEB005800400010 LAST FOILS OF THE STACKS, NEGLIGIBLE AT THE B005800400011 HIGHER ENERGIES), Calibration of the Geli-Detector (3%)B005800400012 , Statistical Errors (1 TO 2%), Photopeak-Analysis(3%),B005800400013 Foil Thickness (3%), Beam Current Integration (2%), andB005800400014 Half-Lives (1 TO 3%). All Errors Mean 3 Standard B005800400015 Deviations. An Additional Error Due to the UncertaintyB005800400016 Of the Gamma Ray Abundance is Mentioned But not B005800400017 Specified. B005800400018 ENDBIB 16 0 B005800400019 NOCOMMON 0 0 B005800400020 DATA 3 8 B005800400021 EN DATA ERR-T B005800400022 MEV MB MB B005800400023 9.5 758. B005800400024 10.6 789. B005800400025 11.6 875. 65. B005800400026 12.6 826. B005800400027 13.4 781. B005800400028 14.3 546. B005800400029 15.1 435. B005800400030 15.9 311. B005800400031 ENDDATA 10 0 B005800400032 ENDSUBENT 31 0 B005800499999 SUBENT B0058005 20011220 0000B005800500001 BIB 5 15 B005800500002 REACTION (28-NI-60(A,N)30-ZN-63,,SIG,,,EXP) B005800500003 RAD-DET (30-ZN-63,DG) B005800500004 DECAY-DATA (30-ZN-63,38.6MIN,DG,670.,0.101) B005800500005 SAMPLE Foils of Natural Ni, Purity Better Than 99.8%, B005800500006 Thickness Approximately 10 Micrometer. B005800500007 ERR-ANALYS (ERR-T) The Accuracy of the Cross Sections is About 6%,B005800500008 Including Uncertainties in Particle Energies (3% IN THEB005800500009 LAST FOILS OF THE STACKS, NEGLIGIBLE AT THE B005800500010 HIGHER ENERGIES), Calibration of the Geli-Detector (3%)B005800500011 , Statistical Errors (<1%), Photopeak-Analysis (3%), B005800500012 Foil Thickness (3%), Beam Current Integration (2%), andB005800500013 Half-Lives (1 TO 3%). All Errors Mean 3 Standard B005800500014 Deviations. An Additional Error Due to the UncertaintyB005800500015 Of the Gamma Ray Abundance is Mentioned But not B005800500016 Specified. B005800500017 ENDBIB 15 0 B005800500018 NOCOMMON 0 0 B005800500019 DATA 3 4 B005800500020 EN DATA ERR-T B005800500021 MEV MB MB B005800500022 18.8 583. B005800500023 20.4 512. 34. B005800500024 22. 395. B005800500025 23.5 268. B005800500026 ENDDATA 6 0 B005800500027 ENDSUBENT 26 0 B005800599999 SUBENT B0058006 20011220 0000B005800600001 BIB 5 15 B005800600002 REACTION (29-CU-63(A,N)31-GA-66,,SIG,,,EXP) B005800600003 RAD-DET (31-GA-66,DG) B005800600004 DECAY-DATA (31-GA-66,9.4HR,DG,1039.,0.39) B005800600005 SAMPLE Foils of Natural Cu, Purity Better Than 99.8%, B005800600006 Thickness Approximately 10 Micrometer. B005800600007 ERR-ANALYS (ERR-T) The Accuracy of the Cross Sections is About 6%,B005800600008 Including Uncertainties in Particle Energies (3% IN THEB005800600009 LAST FOILS OF THE STACKS, NEGLIGIBLE AT THE B005800600010 HIGHER ENERGIES), Calibration of the Geli-Detector (3%)B005800600011 , Statistical Errors (<1%), Photopeak-Analysis (3%), B005800600012 Foil Thickness (3%), Beam Current Integration (2%), andB005800600013 Half-Lives (1 TO 3%). All Errors Mean 3 Standard B005800600014 Deviations. An Additional Error Due to the UncertaintyB005800600015 Of the Gamma Ray Abundance is Mentioned But not B005800600016 Specified. B005800600017 ENDBIB 15 0 B005800600018 NOCOMMON 0 0 B005800600019 DATA 3 4 B005800600020 EN DATA ERR-T B005800600021 MEV MB MB B005800600022 18.9 619. 35. B005800600023 20.5 487. B005800600024 22. 341. B005800600025 23.5 234. B005800600026 ENDDATA 6 0 B005800600027 ENDSUBENT 26 0 B005800699999 SUBENT B0058007 20011220 0000B005800700001 BIB 5 15 B005800700002 REACTION (29-CU-65(A,N)31-GA-68,,SIG,,,EXP) B005800700003 RAD-DET (31-GA-68,DG) B005800700004 DECAY-DATA (31-GA-68,68.3MIN,DG,1077.,0.032) B005800700005 SAMPLE Foils of Natural Cu, Purity Better Than 99.8%, B005800700006 Thickness Approximately 10 Micrometer. B005800700007 ERR-ANALYS (ERR-T) The Accuracy of the Cross Sections is About 6%,B005800700008 Including Uncertainties in Particle Energies (3% IN THEB005800700009 LAST FOILS OF THE STACKS, NEGLIGIBLE AT THE B005800700010 HIGHER ENERGIES), Calibration of the Geli-Detector (3%)B005800700011 , Statistical Errors (1 TO 2%),Photopeak-Analysis (3%),B005800700012 Foil Thickness (3%), Beam Current Integration (2%), andB005800700013 Half-Lives (1 TO 3%). All Errors Mean 3 Standard B005800700014 Deviations. An Additional Error Due to the UncertaintyB005800700015 Of the Gamma Ray Abundance is Mentioned But not B005800700016 Specified. B005800700017 ENDBIB 15 0 B005800700018 NOCOMMON 0 0 B005800700019 DATA 3 4 B005800700020 EN DATA ERR-T B005800700021 MEV MB MB B005800700022 18.9 687. 46. B005800700023 20.5 528. B005800700024 22. 353. B005800700025 23.5 216. B005800700026 ENDDATA 6 0 B005800700027 ENDSUBENT 26 0 B005800799999 ENDENTRY 7 0 B005899999999