ENTRY C0052 20040310 0000C005200000001 SUBENT C0052001 20040310 0000C005200100001 BIB 9 10 C005200100002 INSTITUTE (1CANMCG) C005200100003 REFERENCE (J,CJP,48,2629,1970) C005200100004 AUTHOR (N.P.Goldstein,A.Held,D.G.Stairs) C005200100005 TITLE Elastic scattering of 100 MeV protons from 3He and 4He C005200100006 FACILITY (CYCLO,1CANMCG) C005200100007 METHOD (EDE) C005200100008 DETECTOR Beam monitored using Faraday cup. C005200100009 STATUS Data taken from article. C005200100010 HISTORY (19970625C) C005200100011 (20040310A) Converted to new date formats. C005200100012 ENDBIB 10 0 C005200100013 COMMON 1 3 C005200100014 EN C005200100015 MEV C005200100016 100. C005200100017 ENDCOMMON 3 0 C005200100018 ENDSUBENT 17 0 C005200199999 SUBENT C0052002 19970627 0000C005200200001 BIB 6 20 C005200200002 REACTION (2-HE-3(P,EL)2-HE-3,,DA) C005200200003 SAMPLE 3He gas target mounted in cylindrical scattering C005200200004 chamber with Mylar window. C005200200005 DETECTOR (TELES) Telescopy consisting of a long cylindrical C005200200006 crystal on Naton as the E detector, a thick circular C005200200007 crystal viewed edge-on by a photomultiplier as the C005200200008 delta E detector, and a 3rd detector to eliminate C005200200009 counts from the entrance and exit windows of the gas C005200200010 cell. C005200200011 MONITOR (2-HE-4(P,EL)2-HE-4,,DA) C005200200012 CORRECTION Corrected for: C005200200013 . background, C005200200014 . electronics dead time, C005200200015 . nuclear absoption and outscattering of the detected C005200200016 protons by the counter material, C005200200017 . overlap of elastic and inelastic peak. C005200200018 ERR-ANALYS (DATA-ERR) Includes RMS uncertainty in corrections and C005200200019 error introduced by the angular uncertainty. C005200200020 Total systematic uncertainty ranged from about 13% at C005200200021 small angles to abouy 18% at the largest angles. C005200200022 ENDBIB 20 0 C005200200023 NOCOMMON 0 0 C005200200024 DATA 3 22 C005200200025 ANG-CM DATA-CM DATA-ERR C005200200026 ADEG MB/SR MB/SR C005200200027 27.5 24.0 0.9 C005200200028 32.1 16.5 0.7 C005200200029 40.3 8.5 0.3 C005200200030 46.9 4.72 0.21 C005200200031 53.3 3.01 0.13 C005200200032 58.0 2.03 0.09 C005200200033 65.0 1.41 0.06 C005200200034 70.5 1.12 0.06 C005200200035 78.8 0.74 0.04 C005200200036 83.0 0.64 0.03 C005200200037 88.5 0.47 0.02 C005200200038 94.2 0.40 0.02 C005200200039 100.5 0.260 0.014 C005200200040 106.0 0.231 0.014 C005200200041 110.6 0.182 0.012 C005200200042 123.6 0.111 0.010 C005200200043 133.5 0.065 0.007 C005200200044 136.5 0.061 0.006 C005200200045 139.5 0.051 0.005 C005200200046 143.5 0.061 0.006 C005200200047 149.5 0.079 0.008 C005200200048 153.0 0.110 0.001 C005200200049 ENDDATA 24 0 C005200200050 ENDSUBENT 49 0 C005200299999 SUBENT C0052003 19970627 0000C005200300001 BIB 5 15 C005200300002 REACTION (2-HE-4(P,EL)2-HE-4,,DA) C005200300003 SAMPLE 4He liquid cryostat, cylindrical scattering chamber C005200300004 with Mylar window. C005200300005 DETECTOR (TELES) Telescopy consisting of a long cylindrical C005200300006 crystal on Naton as the E detector and a thick C005200300007 circular crystal viewed edge-on by a photomultiplier C005200300008 as the delta E detector. C005200300009 CORRECTION Corrected for: C005200300010 . background, C005200300011 . electronics dead time, C005200300012 . nuclear absoption and outscattering of the detected C005200300013 protons by the counter material. C005200300014 ERR-ANALYS (DATA-ERR) Includes RMS uncertainty in corrections and C005200300015 error introduced by the angular uncertainty. C005200300016 Total systematic uncertainty estimated to be about 10%.C005200300017 ENDBIB 15 0 C005200300018 NOCOMMON 0 0 C005200300019 DATA 3 1 C005200300020 ANG-CM DATA-CM DATA-ERR C005200300021 ADEG MB/SR MB/SR C005200300022 6.0 136. 20. C005200300023 ENDDATA 3 0 C005200300024 ENDSUBENT 23 0 C005200399999 ENDENTRY 3 0 C005299999999