ENTRY C0110 19990616 0000C011000000001 SUBENT C0110001 19990616 0000C011000100001 BIB 7 12 C011000100002 INSTITUTE (1USATNL,1USADKE,1USANCA) C011000100003 REFERENCE (J,PR/C,49,912,199402) C011000100004 (J,PR/C,45,487,199202) 800-keV data C011000100005 (J,PR/C,43,343,199101) 8.6-MeV data C011000100006 (J,PR/C,40,1517,198909) 400-keV data C011000100007 (J,NIM/A,402,428,1998) 800-keV data C011000100008 AUTHOR (M.J.BALBES,J.C.RILEY,G.FELDMAN,H.R.WELLER,D.R.TILLEY) C011000100009 TITLE Polarized deuteron capture by 3He and 3H at and above C011000100010 the fusion resonance region. C011000100011 CORRECTION Corrected for background. C011000100012 STATUS No reply from H. Weller to author proof. C011000100013 HISTORY (19990423C) Translated from RFNC-VNIIEF database (SD) C011000100014 ENDBIB 12 0 C011000100015 NOCOMMON 0 0 C011000100016 ENDSUBENT 15 0 C011000199999 SUBENT C0110002 19990423 0000C011000200001 BIB 8 14 C011000200002 REACTION (2-HE-3(D,G)3-LI-5,PAR,DA) C011000200003 SAMPLE Gaseous 3He target operated at a pressure of 69.0 kpa C011000200004 with a 1.27 mkm Nickel beam entrance foil and C011000200005 2.54 mkm Havar beam exit foil C011000200006 INC-SOURCE (LAMB) Lamb-shift polarized ion source C011000200007 INC-SPECT Beam degraded using Havar foil. C011000200008 METHOD Beam polarization measured using quench-ratio method. C011000200009 DETECTOR (NAICR) Two 25.4cm*25.4cm NaI(Tl) spectrometers. C011000200010 (SOLST) Monitor: Ortec transmission-mount 500-microm- C011000200011 thick solid-state detector. C011000200012 ERR-ANALYS (ANG-ERR) Digitizing error C011000200013 (DATA-ERR) From graph and digitizing error C011000200014 STATUS (CURVE) Scanned from Fig. 3 of main reference by C011000200015 RFNC-VNIIEF. C011000200016 ENDBIB 14 0 C011000200017 COMMON 3 3 C011000200018 E-LVL EN EN-RSL C011000200019 MEV MEV MEV C011000200020 0.0 0.60 0.08 C011000200021 ENDCOMMON 3 0 C011000200022 DATA 4 7 C011000200023 ANG-CM ANG-ERR DATA-CM DATA-ERR C011000200024 ADEG ADEG MB/SR MB/SR C011000200025 34.38 0.5974 0.1970E-02 0.1527E-04 C011000200026 49.90 0.5974 0.1848E-02 0.1527E-04 C011000200027 70.14 0.5974 0.1842E-02 0.1527E-04 C011000200028 90.37 0.5974 0.1797E-02 0.1959E-03 C011000200029 109.1 0.5974 0.1948E-02 0.1527E-04 C011000200030 130.9 0.5974 0.1942E-02 0.1527E-04 C011000200031 146.5 0.5974 0.1859E-02 0.1175E-03 C011000200032 ENDDATA 9 0 C011000200033 ENDSUBENT 32 0 C011000299999 SUBENT C0110003 19990423 0000C011000300001 BIB 8 15 C011000300002 REACTION (2-HE-3(D,G)3-LI-5,PAR,DA) C011000300003 SAMPLE Gaseous 3He target operated at a pressure of 69.0 kpa C011000300004 with a 1.27 mkm Nickel beam entrance foil and C011000300005 2.54 mkm Havar beam exit foil C011000300006 INC-SOURCE (POLIS) Intense Polarized Ion Source. C011000300007 INC-SPECT Beam degraded using Havar foil. C011000300008 METHOD Beam polarization measured by polarimeter utilizing C011000300009 the 3He(d,p)4He reaction. C011000300010 DETECTOR (NAICR) Two 25.4cm*25.4cm NaI(Tl) spectrometers. C011000300011 (SOLST) Monitor: Ortec transmission-mount 500-microm- C011000300012 thick solid-state detector. C011000300013 ERR-ANALYS (ANG-ERR) Digitizing error C011000300014 (DATA-ERR) From graph and digitizing error C011000300015 STATUS (CURVE) Scanned from Fig. 3 of main reference by C011000300016 RFNC-VNIIEF. C011000300017 ENDBIB 15 0 C011000300018 COMMON 4 3 C011000300019 E-LVL EN EN-RSL DATA-ERR C011000300020 MEV MEV MEV MB/SR C011000300021 0.0 0.80 0.09 0.2941E-04 C011000300022 ENDCOMMON 3 0 C011000300023 DATA 3 7 C011000300024 ANG-CM ANG-ERR DATA-CM C011000300025 ADEG ADEG MB/SR C011000300026 29.70 0.8454 0.1636E-02 C011000300027 49.87 0.8454 0.1669E-02 C011000300028 70.04 0.8454 0.1737E-02 C011000300029 91.76 0.8454 0.1769E-02 C011000300030 110.4 0.8454 0.1802E-02 C011000300031 130.5 0.8454 0.1764E-02 C011000300032 149.1 0.8454 0.1725E-02 C011000300033 ENDDATA 9 0 C011000300034 ENDSUBENT 33 0 C011000399999 SUBENT C0110004 19990423 0000C011000400001 BIB 8 11 C011000400002 REACTION (1-H-3(D,G)2-HE-5,PAR,DA,,RS) C011000400003 SAMPLE Tritiated titanium target which contained approximatelyC011000400004 240 microg/cm2 of tritium. C011000400005 INC-SOURCE (LAMB) Lamb-shift polarized ion source C011000400006 INC-SPECT Beam degraded using Havar foil. C011000400007 METHOD Beam polarization measured using quench-ratio method. C011000400008 DETECTOR (NAICR) Two 25.4cm*25.4cm NaI(Tl) spectrometers. C011000400009 ERR-ANALYS (ANG-ERR) Digitizing error C011000400010 (DATA-ERR) Digitizing error C011000400011 STATUS (CURVE) Scanned from Fig. 4 of main reference by C011000400012 RFNC-VNIIEF. C011000400013 ENDBIB 11 0 C011000400014 COMMON 5 3 C011000400015 EN EN-RSL ANG-ERR E-LVL DATA-ERR C011000400016 MEV MEV ADEG MEV NO-DIM C011000400017 0.4 0.2 0.8227E-01 0.0000E+00 0.1033E-01 C011000400018 ENDCOMMON 3 0 C011000400019 DATA 2 7 C011000400020 ANG-CM DATA-CM C011000400021 ADEG NO-DIM C011000400022 41.37 1.042 C011000400023 49.10 1.002 C011000400024 69.19 0.9233 C011000400025 87.76 1.041 C011000400026 109.4 0.9813 C011000400027 129.5 0.9809 C011000400028 135.7 1.020 C011000400029 ENDDATA 9 0 C011000400030 ENDSUBENT 29 0 C011000499999 SUBENT C0110005 19990423 0000C011000500001 BIB 7 13 C011000500002 REACTION (2-HE-3(D,G)3-LI-5,PAR,DA) C011000500003 SAMPLE Gaseous 3He target operated at a pressure of 69.0 kpa C011000500004 with a 1.27 mkm Nickel beam entrance foil and C011000500005 2.54 mkm Havar beam exit foil C011000500006 INC-SOURCE (LAMB) Lamb-shift polarized ion source C011000500007 METHOD Beam polarization measured using quench-ratio method. C011000500008 DETECTOR (NAICR) Two 25.4cm*25.4cm NaI(Tl) spectrometers. C011000500009 (SOLST) Monitor: Ortec transmission-mount 500-microm- C011000500010 thick solid-state detector. C011000500011 ERR-ANALYS (ANG-ERR) Digitizing error C011000500012 (DATA-ERR) Digitizing error C011000500013 STATUS (CURVE) Scanned from Fig. 7 of main reference by C011000500014 RFNC-VNIIEF. C011000500015 ENDBIB 13 0 C011000500016 COMMON 4 3 C011000500017 EN ANG-ERR E-LVL DATA-ERR C011000500018 MEV ADEG MEV MB/SR C011000500019 8.600 1.472 0.0000E+00 0.4158E-04 C011000500020 ENDCOMMON 3 0 C011000500021 DATA 2 7 C011000500022 ANG-CM DATA-CM C011000500023 ADEG MB/SR C011000500024 36.00 0.1673E-02 C011000500025 51.57 0.1909E-02 C011000500026 71.81 0.2225E-02 C011000500027 93.60 0.2380E-02 C011000500028 113.8 0.2376E-02 C011000500029 132.4 0.2132E-02 C011000500030 151.1 0.2208E-02 C011000500031 ENDDATA 9 0 C011000500032 ENDSUBENT 31 0 C011000599999 SUBENT C0110006 19990423 0000C011000600001 BIB 7 10 C011000600002 REACTION (1-H-3(D,G)2-HE-5,PAR,DA) C011000600003 SAMPLE Tritiated titanium target which contained approximatelyC011000600004 240 microg/cm2 of tritium. C011000600005 INC-SOURCE (LAMB) Lamb-shift polarized ion source C011000600006 METHOD Beam polarization measured using quench-ratio method. C011000600007 DETECTOR (NAICR) Two 25.4cm*25.4cm NaI(Tl) spectrometers. C011000600008 ERR-ANALYS (ANG-ERR) Digitizing error C011000600009 (DATA-ERR) Digitizing error C011000600010 STATUS (CURVE) Scanned from Fig. 7 of main reference by C011000600011 RFNC-VNIIEF. C011000600012 ENDBIB 10 0 C011000600013 COMMON 4 3 C011000600014 EN ANG-ERR E-LVL DATA-ERR C011000600015 MEV ADEG MEV MB/SR C011000600016 8.600 1.507 0.0000E+00 0.4752E-04 C011000600017 ENDCOMMON 3 0 C011000600018 DATA 2 7 C011000600019 ANG-CM DATA-CM C011000600020 ADEG MB/SR C011000600021 43.14 0.9331E-03 C011000600022 50.92 0.1008E-02 C011000600023 72.66 0.9945E-03 C011000600024 92.86 0.1062E-02 C011000600025 113.0 0.9690E-03 C011000600026 131.7 0.9573E-03 C011000600027 139.4 0.7923E-03 C011000600028 ENDDATA 9 0 C011000600029 ENDSUBENT 28 0 C011000699999 ENDENTRY 6 0 C011099999999