ENTRY C0261 20181205 C183C026100000001 SUBENT C0261001 20181205 C183C026100100001 BIB 11 32 C026100100002 TITLE Spallation of Aluminum by 28-GeV Protons C026100100003 AUTHOR (J.B.Cumming,G.Friedlander,J.Hudis,A.M.Poskanzer) C026100100004 REFERENCE (J,PR,127,950,1962) C026100100005 #doi:10.1103/PhysRev.127.950 C026100100006 INSTITUTE (1USABNL) C026100100007 FACILITY (SYNCH,1USABNL) The Brookhaven alternating gradient C026100100008 synchrotron. C026100100009 METHOD (ACTIV,STTA) Stacks of aluminum and polyethylene or C026100100010 polystyrene foils were irradiated in the internal C026100100011 beam of the Brookhaven alternating gradient C026100100012 synchrotron at an energy of 28 GeV. C026100100013 MONITOR (6-C-12(P,X)6-C-11,,SIG) C026100100014 MONIT-REF ((MONIT)C0231001,J.B.Cumming+,J,PR,125,2078,1962) C026100100015 ERR-ANALYS (DATA-ERR) The errors on the individual values have C026100100016 been compounded from the errors due to counting C026100100017 statistics (negligible for Na24 and F18) and a 1.5% C026100100018 error to allow for uncertainties in weighing and foil C026100100019 line-up and for small day-to-day variations of the C026100100020 counter efficiencies from the calibrated values. C026100100021 Errors include estimates of systematic effects but do C026100100022 not include the 4.6% error in the C12(p,pn)C11 cross C026100100023 section. C026100100024 (ERR-1) Uncertainties in weighing and foil line-up C026100100025 and for small day-to-day variations of the counter C026100100026 efficiencies from the calibrated values. C026100100027 STATUS (TABLE) Table II, page 952. C026100100028 HISTORY (19870602C) C026100100029 (19961009A) Monitor corrected, converted to lower case.C026100100030 (20181205A) BP: Updated information, added doi, updatedC026100100031 subentry 10, changed to new date formats. C026100100032 Corrections according last EXFOR rules and C026100100033 Dict. C026100100034 ENDBIB 32 0 C026100100035 COMMON 4 3 C026100100036 EN MONIT MONIT-ERR ERR-1 C026100100037 GEV MB MB PER-CENT C026100100038 28. 25.9 1.2 1.5 C026100100039 ENDCOMMON 3 0 C026100100040 ENDSUBENT 39 0 C026100199999 SUBENT C0261002 19961009 0000C026100200001 BIB 4 4 C026100200002 REACTION (13-AL-27(P,X)4-BE-7,,SIG) C026100200003 DETECTOR (NAICR) C026100200004 DECAY-DATA (4-BE-7,54.D,DG,477.,0.12) C026100200005 SAMPLE Aluminum foils C026100200006 ENDBIB 4 0 C026100200007 NOCOMMON 0 0 C026100200008 DATA 2 1 C026100200009 DATA DATA-ERR C026100200010 MB MB C026100200011 7.9 0.5 C026100200012 ENDDATA 3 0 C026100200013 ENDSUBENT 12 0 C026100299999 SUBENT C0261003 19961009 0000C026100300001 BIB 4 4 C026100300002 REACTION (13-AL-27(P,X)6-C-11,,SIG) C026100300003 DETECTOR (NAICR) C026100300004 DECAY-DATA (6-C-11,20.4MIN,AR,511.,1.0) C026100300005 SAMPLE Aluminum foils C026100300006 ENDBIB 4 0 C026100300007 NOCOMMON 0 0 C026100300008 DATA 2 1 C026100300009 DATA DATA-ERR C026100300010 MB MB C026100300011 4.7 0.2 C026100300012 ENDDATA 3 0 C026100300013 ENDSUBENT 12 0 C026100399999 SUBENT C0261004 19961009 0000C026100400001 BIB 4 4 C026100400002 REACTION (13-AL-27(P,X)7-N-13,,SIG) C026100400003 DETECTOR (NAICR) C026100400004 DECAY-DATA (7-N-13,10.0MIN,AR,511.,1.0) C026100400005 SAMPLE Aluminum foils C026100400006 ENDBIB 4 0 C026100400007 NOCOMMON 0 0 C026100400008 DATA 2 1 C026100400009 DATA DATA-ERR C026100400010 MB MB C026100400011 1.18 0.07 C026100400012 ENDDATA 3 0 C026100400013 ENDSUBENT 12 0 C026100499999 SUBENT C0261005 19961009 0000C026100500001 BIB 4 4 C026100500002 REACTION (13-AL-27(P,X)8-O-15,,SIG) C026100500003 DETECTOR (NAICR) C026100500004 DECAY-DATA (8-O-15,2.05MIN,AR,511.,1.0) C026100500005 SAMPLE Aluminum foils C026100500006 ENDBIB 4 0 C026100500007 NOCOMMON 0 0 C026100500008 DATA 2 1 C026100500009 DATA DATA-ERR C026100500010 MB MB C026100500011 3.5 1.0 C026100500012 ENDDATA 3 0 C026100500013 ENDSUBENT 12 0 C026100599999 SUBENT C0261006 19961009 0000C026100600001 BIB 4 4 C026100600002 REACTION (13-AL-27(P,X)9-F-18,,SIG) C026100600003 DETECTOR (NAICR) C026100600004 DECAY-DATA (9-F-18,110.MIN,AR,511.,0.97) C026100600005 SAMPLE Aluminum foils C026100600006 ENDBIB 4 0 C026100600007 NOCOMMON 0 0 C026100600008 DATA 2 1 C026100600009 DATA DATA-ERR C026100600010 MB MB C026100600011 6.0 0.3 C026100600012 ENDDATA 3 0 C026100600013 ENDSUBENT 12 0 C026100699999 SUBENT C0261007 19961009 0000C026100700001 BIB 4 4 C026100700002 REACTION (13-AL-27(P,X)11-NA-22,,SIG) C026100700003 DETECTOR (NAICR) C026100700004 DECAY-DATA (11-NA-22,2.59YR,DG,1280.,1.0) C026100700005 SAMPLE Aluminum foils C026100700006 ENDBIB 4 0 C026100700007 NOCOMMON 0 0 C026100700008 DATA 2 1 C026100700009 DATA DATA-ERR C026100700010 MB MB C026100700011 9.8 0.6 C026100700012 ENDDATA 3 0 C026100700013 ENDSUBENT 12 0 C026100799999 SUBENT C0261008 19961009 0000C026100800001 BIB 5 6 C026100800002 REACTION (13-AL-27(P,X)11-NA-24,,SIG) C026100800003 DETECTOR (NAICR) 1.37- and 2.75-MeV gammas C026100800004 (PROPC) 1.4-MeV beta spectrum C026100800005 DECAY-DATA (11-NA-24,15.0HR,DG,1370.,1.0,DG,2750.,1.0) C026100800006 SAMPLE Aluminum foils C026100800007 CORRECTION CROSS SECTION WAS CORRECTED FOR SECONDARY EFFECT. C026100800008 ENDBIB 6 0 C026100800009 NOCOMMON 0 0 C026100800010 DATA 2 1 C026100800011 DATA DATA-ERR C026100800012 MB MB C026100800013 8.3 0.5 C026100800014 ENDDATA 3 0 C026100800015 ENDSUBENT 14 0 C026100899999 SUBENT C0261009 19961009 0000C026100900001 BIB 4 4 C026100900002 REACTION (13-AL-27(P,X)10-NE-24,,SIG) C026100900003 DETECTOR (NAICR) C026100900004 DECAY-DATA (10-NE-24,3.4MIN,DG,472.,1.0,DG,878.,0.08) C026100900005 SAMPLE Aluminum foils C026100900006 ENDBIB 4 0 C026100900007 NOCOMMON 0 0 C026100900008 DATA 1 1 C026100900009 DATA-MAX C026100900010 MB C026100900011 0.6 C026100900012 ENDDATA 3 0 C026100900013 ENDSUBENT 12 0 C026100999999 SUBENT C0261010 20181205 C183C026101000001 BIB 7 8 C026101000002 REACTION (13-AL-27(P,X)12-MG-27,,SIG) C026101000003 DETECTOR (NAICR) C026101000004 DECAY-DATA (12-MG-27,9.5MIN,DG,834.,0.70) C026101000005 SAMPLE Aluminum foils C026101000006 CORRECTION Cross section was corrected for secondary effect. C026101000007 REL-REF (O,C2357010,A.M.Poskanzer+,J,PR,168,1331,1968) Latest C026101000008 results for multiple beam energies. C026101000009 HISTORY (20181205A) BP: Added REL-REF, DATA-ERR correction. C026101000010 ENDBIB 8 0 C026101000011 NOCOMMON 0 0 C026101000012 DATA 2 1 C026101000013 DATA DATA-ERR C026101000014 MB MB C026101000015 0.067 0.005 C026101000016 ENDDATA 3 0 C026101000017 ENDSUBENT 16 0 C026101099999 SUBENT C0261011 19961009 0000C026101100001 BIB 4 4 C026101100002 REACTION (6-C-0(P,X)4-BE-7,,SIG) C026101100003 DETECTOR (NAICR) C026101100004 DECAY-DATA (4-BE-7,54.D,DG,477.,0.12) C026101100005 SAMPLE Polyrthylene or polystyrene foils. C026101100006 ENDBIB 4 0 C026101100007 NOCOMMON 0 0 C026101100008 DATA 2 1 C026101100009 DATA DATA-ERR C026101100010 MB MB C026101100011 7.7 0.4 C026101100012 ENDDATA 3 0 C026101100013 ENDSUBENT 12 0 C026101199999 ENDENTRY 11 0 C026199999999