ENTRY C0413 20191125 C187C041300000001 SUBENT C0413001 20191125 C187C041300100001 BIB 12 34 C041300100002 TITLE Fission of polonium, osmium, and erbium composite C041300100003 systems C041300100004 AUTHOR (J.Van Der Plicht,H.C.Britt,M.M.Fowler,Z.Fraenkel, C041300100005 A.Gavron,J.B.Wilhelmy,F.Plasil,T.C.Awes,G.R.Young) C041300100006 REFERENCE (J,PR/C,28,2022,1983) C041300100007 #doi:10.1103/PhysRevC.28.2022 C041300100008 INSTITUTE (1USALAS,1USAORL) C041300100009 FACILITY (LINAC,1USABRK) Heavy Ion Linear Accelerator (Hilac). C041300100010 SAMPLE Targets were generally in 100-250 microg/cm2 C041300100011 thickness range. Some targets were in the form of C041300100012 oxides on carbon backings. C041300100013 DETECTOR (MWPC) C041300100014 METHOD (TOF) Approximate flight paths were 21 cm for C041300100015 fragment 1 (start to stop1) and 17 cm for fragment 2 C041300100016 (target to stop2). The TOF spectra were calibrated C041300100017 using 252Cf source and time-to-amplitude converter C041300100018 calibrator. C041300100019 ANALYSIS (NTRTH) Absolute differential cross sections were C041300100020 calculated using measured geometries and assuming C041300100021 Rutherford scattering in the monitor detectors. C041300100022 Total fission cross sections calculated from C041300100023 dsigma(theta=57deg.) assuming an angular distribution C041300100024 proportional to 1/sin(theta). C041300100025 ERR-ANALYS (ERR-S) Statistical errors are less than 5% except C041300100026 where indicated. C041300100027 (ERR-SYS,,10.) Absolute uncertainty in the measured C041300100028 cross sections is believed to have a systematic C041300100029 uncertainty of less than 10%. C041300100030 STATUS (TABLE) Table I, pages 2025-2026. C041300100031 HISTORY (19880204C) C041300100032 (19960425A) BIB update, converted to lower case. C041300100033 Monitor added to subentries. C041300100034 (20191125A) BP: Updated entry and uncertainties, C041300100035 added doi. C041300100036 ENDBIB 34 0 C041300100037 NOCOMMON 0 0 C041300100038 ENDSUBENT 37 0 C041300199999 SUBENT C0413002 20191125 C187C041300200001 BIB 2 2 C041300200002 REACTION (60-ND-142(8-O-16,F),,SIG) C041300200003 MONITOR (60-ND-142(8-O-16,EL)60-ND-142,,DA,,RTH) C041300200004 ENDBIB 2 0 C041300200005 NOCOMMON 0 0 C041300200006 DATA 3 7 C041300200007 EN DATA ERR-S C041300200008 MEV MB MB C041300200009 95. 0.055 0.007 C041300200010 100. 0.230 0.020 C041300200011 105. 0.740 0.050 C041300200012 110. 2.37 C041300200013 120. 9.2 C041300200014 130. 21.6 C041300200015 140. 38.5 C041300200016 ENDDATA 9 0 C041300200017 ENDSUBENT 16 0 C041300299999 SUBENT C0413003 20191125 C187C041300300001 BIB 2 2 C041300300002 REACTION (56-BA-134(12-MG-24,F),,SIG) C041300300003 MONITOR (56-BA-134(12-MG-24,EL)56-BA-134,,DA,,RTH) C041300300004 ENDBIB 2 0 C041300300005 NOCOMMON 0 0 C041300300006 DATA 3 8 C041300300007 EN DATA ERR-S C041300300008 MEV MB MB C041300300009 120. 1.13 0.30 C041300300010 125. 3.57 0.40 C041300300011 130. 11.4 C041300300012 140. 51.6 C041300300013 150. 124. C041300300014 160. 188. C041300300015 170. 251. C041300300016 180. 302. C041300300017 ENDDATA 10 0 C041300300018 ENDSUBENT 17 0 C041300399999 SUBENT C0413004 20191125 C187C041300400001 BIB 2 2 C041300400002 REACTION (52-TE-126(16-S-32,F),,SIG) C041300400003 MONITOR (52-TE-126(16-S-32,EL)52-TE-126,,DA,,RTH) C041300400004 ENDBIB 2 0 C041300400005 NOCOMMON 0 0 C041300400006 DATA 3 6 C041300400007 EN DATA ERR-S C041300400008 MEV MB MB C041300400009 150. 5.0 C041300400010 155. 13.7 C041300400011 160. 38.6 C041300400012 180. 195. 20. C041300400013 200. 372. 40. C041300400014 220. 445. 50. C041300400015 ENDDATA 8 0 C041300400016 ENDSUBENT 15 0 C041300499999 SUBENT C0413005 20191125 C187C041300500001 BIB 2 2 C041300500002 REACTION (40-ZR-94(28-NI-64,F),,SIG) C041300500003 MONITOR (40-ZR-94(28-NI-64,EL)40-ZR-94,,DA,,RTH) C041300500004 ENDBIB 2 0 C041300500005 NOCOMMON 0 0 C041300500006 DATA 5 3 C041300500007 EN DATA ERR-S +DATA-ERR -DATA-ERR C041300500008 MEV MB MB MB MB C041300500009 250. 9. 11. 9. C041300500010 270. 105. 30. C041300500011 290. 420. 80. C041300500012 ENDDATA 5 0 C041300500013 ENDSUBENT 12 0 C041300599999 SUBENT C0413006 20191125 C187C041300600001 BIB 2 2 C041300600002 REACTION (72-HF-177(4-BE-9,F),,SIG) C041300600003 MONITOR (72-HF-177(4-BE-9,EL)72-HF-177,,DA,,RTH) C041300600004 ENDBIB 2 0 C041300600005 NOCOMMON 0 0 C041300600006 DATA 3 5 C041300600007 EN DATA ERR-S C041300600008 MEV MB MB C041300600009 64. 0.42 0.07 C041300600010 68. 0.90 0.11 C041300600011 72. 2.20 0.16 C041300600012 80. 5.10 C041300600013 84. 7.2 C041300600014 ENDDATA 7 0 C041300600015 ENDSUBENT 14 0 C041300699999 SUBENT C0413007 20191125 C187C041300700001 BIB 2 2 C041300700002 REACTION (70-YB-174(6-C-12,F),,SIG) C041300700003 MONITOR (70-YB-174(6-C-12,EL)70-YB-174,,DA,,RTH) C041300700004 ENDBIB 2 0 C041300700005 NOCOMMON 0 0 C041300700006 DATA 3 10 C041300700007 EN DATA ERR-S C041300700008 MEV MB MB C041300700009 65. 0.023 0.003 C041300700010 70. 0.092 0.010 C041300700011 75. 0.390 C041300700012 80. 0.99 C041300700013 85. 2.50 C041300700014 90. 5.38 C041300700015 100. 19.4 C041300700016 110. 49.1 C041300700017 115. 71.5 C041300700018 120. 95.1 C041300700019 ENDDATA 12 0 C041300700020 ENDSUBENT 19 0 C041300799999 SUBENT C0413008 20191125 C187C041300800001 BIB 2 2 C041300800002 REACTION (68-ER-170(8-O-16,F),,SIG) C041300800003 MONITOR (68-ER-170(8-O-16,EL)68-ER-170,,DA,,RTH) C041300800004 ENDBIB 2 0 C041300800005 NOCOMMON 0 0 C041300800006 DATA 3 10 C041300800007 EN DATA ERR-S C041300800008 MEV MB MB C041300800009 80. 0.06 0.01 C041300800010 85. 0.31 0.02 C041300800011 90. 1.19 C041300800012 95. 3.64 C041300800013 100. 8.5 C041300800014 110. 43.2 C041300800015 120. 113. C041300800016 130. 209. C041300800017 140. 294. C041300800018 150. 371. C041300800019 ENDDATA 12 0 C041300800020 ENDSUBENT 19 0 C041300899999 SUBENT C0413009 20191125 C187C041300900001 BIB 2 2 C041300900002 REACTION (64-GD-160(12-MG-26,F),,SIG) C041300900003 MONITOR (64-GD-160(12-MG-26,EL)64-GD-160,,DA,,RTH) C041300900004 ENDBIB 2 0 C041300900005 NOCOMMON 0 0 C041300900006 DATA 3 6 C041300900007 EN DATA ERR-S C041300900008 MEV MB MB C041300900009 120. 13.6 1.5 C041300900010 130. 84. C041300900011 140. 208. C041300900012 150. 363. C041300900013 160. 515. C041300900014 170. 651. C041300900015 ENDDATA 8 0 C041300900016 ENDSUBENT 15 0 C041300999999 SUBENT C0413010 20191125 C187C041301000001 BIB 2 2 C041301000002 REACTION (78-PT-198(6-C-12,F),,SIG) C041301000003 MONITOR (78-PT-198(6-C-12,EL)78-PT-198,,DA,,RTH) C041301000004 ENDBIB 2 0 C041301000005 NOCOMMON 0 0 C041301000006 DATA 3 12 C041301000007 EN DATA ERR-S C041301000008 MEV MB MB C041301000009 55. 0.003 0.002 C041301000010 58. 0.20 0.02 C041301000011 60. 0.79 0.08 C041301000012 65. 5.1 C041301000013 70. 16.6 C041301000014 75. 38.7 C041301000015 80. 74.7 C041301000016 85. 136. C041301000017 90. 209. C041301000018 100. 399. C041301000019 110. 601. C041301000020 120. 775. C041301000021 ENDDATA 14 0 C041301000022 ENDSUBENT 21 0 C041301099999 SUBENT C0413011 19970425 0000C041301100001 BIB 2 2 C041301100002 REACTION (76-OS-192(8-O-18,F),,SIG) C041301100003 MONITOR (76-OS-192(8-O-18,EL)76-OS-192,,DA,,RTH) C041301100004 ENDBIB 2 0 C041301100005 NOCOMMON 0 0 C041301100006 DATA 2 10 C041301100007 EN DATA C041301100008 MEV MB C041301100009 78. 2.4 C041301100010 80. 5.3 C041301100011 85. 21.0 C041301100012 90. 57. C041301100013 100. 221. C041301100014 110. 486. C041301100015 120. 753. C041301100016 130. 963. C041301100017 140. 1100. C041301100018 150. 1230. C041301100019 ENDDATA 12 0 C041301100020 ENDSUBENT 19 0 C041301199999 SUBENT C0413012 19970425 0000C041301200001 BIB 2 2 C041301200002 REACTION (76-OS-192(8-O-16,F),,SIG) C041301200003 MONITOR (76-OS-192(8-O-16,EL)76-OS-192,,DA,,RTH) C041301200004 ENDBIB 2 0 C041301200005 NOCOMMON 0 0 C041301200006 DATA 2 7 C041301200007 EN DATA C041301200008 MEV MB C041301200009 80. 8.3 C041301200010 90. 76.2 C041301200011 100. 270. C041301200012 110. 540. C041301200013 120. 770. C041301200014 130. 944. C041301200015 140. 1130. C041301200016 ENDDATA 9 0 C041301200017 ENDSUBENT 16 0 C041301299999 SUBENT C0413013 19970425 0000C041301300001 BIB 2 2 C041301300002 REACTION (76-OS-190(8-O-16,F),,SIG) C041301300003 MONITOR (76-OS-190(8-O-16,EL)76-OS-190,,DA,,RTH) C041301300004 ENDBIB 2 0 C041301300005 NOCOMMON 0 0 C041301300006 DATA 2 7 C041301300007 EN DATA C041301300008 MEV MB C041301300009 80. 16.4 C041301300010 90. 139. C041301300011 100. 405. C041301300012 110. 701. C041301300013 120. 914. C041301300014 130. 1070. C041301300015 140. 1260. C041301300016 ENDDATA 9 0 C041301300017 ENDSUBENT 16 0 C041301399999 SUBENT C0413014 19970425 0000C041301400001 BIB 2 2 C041301400002 REACTION (76-OS-188(8-O-18,F),,SIG) C041301400003 MONITOR (76-OS-188(8-O-18,EL)76-OS-188,,DA,,RTH) C041301400004 ENDBIB 2 0 C041301400005 NOCOMMON 0 0 C041301400006 DATA 2 4 C041301400007 EN DATA C041301400008 MEV MB C041301400009 80. 18.9 C041301400010 100. 486. C041301400011 120. 1035. C041301400012 140. 1310. C041301400013 ENDDATA 6 0 C041301400014 ENDSUBENT 13 0 C041301499999 SUBENT C0413015 19970425 0000C041301500001 BIB 2 2 C041301500002 REACTION (76-OS-188(8-O-16,F),,SIG) C041301500003 MONITOR (76-OS-188(8-O-16,EL)76-OS-188,,DA,,RTH) C041301500004 ENDBIB 2 0 C041301500005 NOCOMMON 0 0 C041301500006 DATA 2 7 C041301500007 EN DATA C041301500008 MEV MB C041301500009 80. 28.9 C041301500010 90. 230. C041301500011 100. 545. C041301500012 110. 855. C041301500013 120. 1070. C041301500014 130. 1260. C041301500015 140. 1380. C041301500016 ENDDATA 9 0 C041301500017 ENDSUBENT 16 0 C041301599999 ENDENTRY 15 0 C041399999999