ENTRY C0451 19970626 0000C045100000001 SUBENT C0451001 19970626 0000C045100100001 BIB 9 16 C045100100002 INSTITUTE (1USAINU,3POLWWA) C045100100003 REFERENCE (J,PR/C,41,2605,9006) C045100100004 AUTHOR (W.SKULSKI,J.JASTRZEBSKI,P.P.SINGH,Q.CHEN,M.FATYGA) C045100100005 TITLE Limitation of the linear momentum transfer on 4He+59Co C045100100006 collisions C045100100007 FACILITY (CYCLO,1USAINU) C045100100008 DETECTOR (GELI) Ge(lI) gamma-ray detector enclosed in lead C045100100009 shielding to reduce background. Resolution is 2.3 keVC045100100010 for 1.33-MeV gamma from 59Co and a 17% efficiency withC045100100011 respect to a NaI(Tl) crystal. C045100100012 Beam charge determined using Faraday cup and calibratedC045100100013 charge integrator. C045100100014 ERR-ANALYS (DATA-ERR) No information on source of uncertainties. C045100100015 STATUS Data taken from table in article. C045100100016 No reply to author proof sent to W. Skulski. C045100100017 HISTORY (970512C) C045100100018 ENDBIB 16 0 C045100100019 COMMON 1 3 C045100100020 EN C045100100021 MEV C045100100022 200. C045100100023 ENDCOMMON 3 0 C045100100024 ENDSUBENT 23 0 C045100199999 SUBENT C0451002 19970513 0000C045100200001 BIB 5 12 C045100200002 REACTION (27-CO-59(A,X)ELEM/MASS,,SIG) C045100200003 SAMPLE Two thin (about 100 microg/cm2) cobalt targets C045100200004 evaporated on berylium backing. Small target C045100200005 impurities (mainly Fe) of about 2% of cobalt by weightC045100200006 found on each side of the Be support foil. C045100200007 METHOD (ACTIV) Thin target-thin catcher (off-line) technique. C045100200008 Carbon foils used to stop recioling nucleus. C045100200009 Typically 5 catcher foils placed upstream and 25 C045100200010 placed downstream. Each catcher activity was measuredC045100200011 several times during the few months after irradiation.C045100200012 DECAY-DATA No information on decay data used. C045100200013 MONITOR Normalized to in-beam measurements. C045100200014 ENDBIB 12 0 C045100200015 NOCOMMON 0 0 C045100200016 DATA 4 20 C045100200017 ELEMENT MASS DATA DATA-ERR C045100200018 NO-DIM NO-DIM MB MB C045100200019 28. 60. 20. 5. C045100200020 28. 59. 28. 13. C045100200021 28. 58. 8. 2. C045100200022 27. 59. 70. 15. C045100200023 26. 58. 20. 10. C045100200024 26. 57. 94. 10. C045100200025 26. 56. 131. 10. C045100200026 26. 55. 77. 10. C045100200027 26. 54. 27. 3. C045100200028 26. 53. 3. C045100200029 25. 55. 28. 3. C045100200030 25. 53. 57. 6. C045100200031 25. 51. 8. 1. C045100200032 24. 54. 10. 5. C045100200033 24. 53. 14. 3. C045100200034 24. 52. 60. 5. C045100200035 24. 50. 22. 1. C045100200036 23. 51. 8. 2. C045100200037 23. 49. 35. 10. C045100200038 22. 46. 9. 1. C045100200039 ENDDATA 22 0 C045100200040 ENDSUBENT 39 0 C045100299999 SUBENT C0451003 19970513 0000C045100300001 BIB 3 3 C045100300002 REACTION (27-CO-59(A,X)ELEM/MASS,,SIG) C045100300003 SAMPLE 20-mg/cm2 cobalt target. C045100300004 METHOD (GSPEC) In-beam gamma spectra measurement. C045100300005 ENDBIB 3 0 C045100300006 NOCOMMON 0 0 C045100300007 DATA 4 15 C045100300008 ELEMENT MASS DATA DATA-ERR C045100300009 NO-DIM NO-DIM MB MB C045100300010 28. 57. 2.4 0.4 C045100300011 27. 58. 159. 8. C045100300012 27. 57. 106. 5. C045100300013 27. 56. 42. 10. C045100300014 27. 55. 4.3 0.2 C045100300015 26. 52. 0.50 0.04 C045100300016 25. 56. 9.0 0.5 C045100300017 25. 54. 107. 5. C045100300018 25. 52. 41. 1. C045100300019 24. 51. 80. 10. C045100300020 24. 48. 0.5 0.1 C045100300021 23. 48. 20. 2. C045100300022 21. 47. 4.0 0.5 C045100300023 21. 46. 6. 1. C045100300024 21. 44. 6.4 0.3 C045100300025 ENDDATA 17 0 C045100300026 ENDSUBENT 25 0 C045100399999 ENDENTRY 3 0 C045199999999