ENTRY C0463 20140418 C141C046300000001 SUBENT C0463001 20140418 C141C046300100001 BIB 12 24 C046300100002 INSTITUTE (1CANTMF,1USAINU,1USAKNT,1USAOHO) C046300100003 REFERENCE (J,PR/C,30,1999,198412) C046300100004 AUTHOR (J.D'auria,M.Dombsky,L.Moritz,T.Ruth,G.Sheffer, C046300100005 T.E.Ward,C.C.Foster,J.W.Watson,B.D.Anderson,J.Rapaport)C046300100006 TITLE Activation measurements of the 7Li(p,n)7Be reaction C046300100007 from 60 - 480 MeV. C046300100008 REL-REF (O,A0172001,T.E.Ward+,J,PR/C,25,762,1982) C046300100009 - data are presented in Tbl. 1 of PR/C,30,1999 for C046300100010 completeness C046300100011 INC-SOURCE External beams of protons. C046300100012 METHOD (ACTIV,EXTB) C046300100013 DECAY-DATA (4-BE-7,53.29D,DG,478.) C046300100014 CORRECTION Not corrected for recoil loss (estimated negligible). C046300100015 ERR-ANALYS (ERR-T) Total uncertainty obtained from combining C046300100016 in quadrature the following uncertainties due to: C046300100017 (ERR-S) - counting statistics (3%); C046300100018 (ERR-1,3.,10.) - efficiency determinations (3-10%); C046300100019 (ERR-2,5.,10.) - target thickness determinations (5-10%C046300100020 (ERR-3,5.,6.) - beam current integration (5-6%). C046300100021 (ERR-4) Relative uncertainty 9.7%. C046300100022 STATUS (TABLE) Data taken from the Table 1 in PR/C,30,1999. C046300100023 (APRVD) Approved by J. D'Auria, 30 March 1999. C046300100024 HISTORY (19990216C) VV C046300100025 (20140418U) SD: ERR-ANALYS updated. C046300100026 ENDBIB 24 0 C046300100027 COMMON 5 3 C046300100028 EN-ERR E-LVL E-LVL ERR-4 ERR-S C046300100029 MEV MEV MEV PER-CENT PER-CENT C046300100030 0.1 0.0 0.429 6. 3. C046300100031 ENDCOMMON 3 0 C046300100032 ENDSUBENT 31 0 C046300199999 SUBENT C0463002 20140418 C141C046300200001 BIB 6 9 C046300200002 REACTION (3-LI-7(P,N)4-BE-7,PAR,SIG) C046300200003 FACILITY (CYCLO,1USAINU) Indiana University Cyclotron C046300200004 Facility (IUCF). C046300200005 SAMPLE 7LiCl targets (about of 40 mg/cm**2) and KCl C046300200006 targets (about 100 mg/cm**2). C046300200007 METHOD (BCINT) C046300200008 DETECTOR (GELI) PGT Germanium-Lithium detector. C046300200009 MONITOR Detector efficiency determined using standard NBS C046300200010 gamma reference sources. C046300200011 ENDBIB 9 0 C046300200012 NOCOMMON 0 0 C046300200013 DATA 3 4 C046300200014 EN DATA ERR-T C046300200015 MEV MB MB C046300200016 60.1 12.00 1.03 C046300200017 135.0 5.31 0.53 C046300200018 160.1 4.52 0.41 C046300200019 190.0 3.50 0.35 C046300200020 ENDDATA 6 0 C046300200021 ENDSUBENT 20 0 C046300299999 SUBENT C0463003 20140418 C141C046300300001 BIB 7 12 C046300300002 REACTION (3-LI-7(P,N)4-BE-7,PAR,SIG) C046300300003 FACILITY (CYCLO,1USAINU) Indiana University Cyclotron C046300300004 Facility (IUCF). C046300300005 SAMPLE (3-LI-7,ENR=0.99999) Isotopically pure (99.999 %) 7Li C046300300006 metal discs with diameter 2 cm and thickness of C046300300007 6 - 100 mg/cm**2. C046300300008 DETECTOR (GELI) PGT Germanium-Lithium detector. C046300300009 METHOD (BCINT) C046300300010 MONITOR Detector efficiency determined using standard NBS C046300300011 gamma reference sources. C046300300012 ANALYSIS Value given at 60.1 MeV is weighted mean of thick and C046300300013 thin target measurements. C046300300014 ENDBIB 12 0 C046300300015 NOCOMMON 0 0 C046300300016 DATA 3 4 C046300300017 EN DATA ERR-T C046300300018 MEV MB MB C046300300019 60.1 12.02 1.02 C046300300020 135.0 4.30 0.41 C046300300021 160.1 3.77 0.40 C046300300022 190.0 3.01 0.24 C046300300023 ENDDATA 6 0 C046300300024 ENDSUBENT 23 0 C046300399999 SUBENT C0463004 20140418 C141C046300400001 BIB 6 13 C046300400002 REACTION (3-LI-7(P,N)4-BE-7,PAR,SIG) C046300400003 FACILITY (CYCLO,1CANTMF) TRIUMF. C046300400004 SAMPLE (3-LI-7,ENR=0.99999) Isotopically pure (99.999 %) 7Li C046300400005 metal discs with diameter 2 cm and thickness of C046300400006 6 - 100 mg/cm**2. C046300400007 DETECTOR (GELI) ORTEC Ge(Li) detector. C046300400008 MONITOR Stack of three Al metal foils used both to monitor C046300400009 the incident flux and to estimate losses due to C046300400010 7Be recoil nuclei. C046300400011 Detector efficiency determined using standard IAEA C046300400012 gamma reference sources. C046300400013 ANALYSIS Values given at 301, 400, and 480 MeV are weighted C046300400014 mean of thick and thin target measurements. C046300400015 ENDBIB 13 0 C046300400016 NOCOMMON 0 0 C046300400017 DATA 3 6 C046300400018 EN DATA ERR-T C046300400019 MEV MB MB C046300400020 191.0 2.85 0.19 C046300400021 252.0 2.58 0.30 C046300400022 301.0 1.73 0.10 C046300400023 349.0 1.41 0.26 C046300400024 400.0 1.47 0.18 C046300400025 480.0 1.08 0.07 C046300400026 ENDDATA 8 0 C046300400027 ENDSUBENT 26 0 C046300499999 ENDENTRY 4 0 C046399999999