ENTRY C0784 20010326 0000C078400000001 SUBENT C0784001 20010326 0000C078400100001 BIB 8 11 C078400100002 INSTITUTE (1CANMCM,1USADKE,1USATNL) C078400100003 REFERENCE (J,PR/C,38,2503,198812) C078400100004 AUTHOR (M.C.VETTERLI,J.A.KUEHNER,C.BAMBER,N.DAVIS,A.J.TRUDEL, C078400100005 H.R.WELLER,R.M.WHITTON) C078400100006 TITLE Vector analyzing powers for 1H(d(pol),gamma)3He and C078400100007 2H(p(pol),gamma)3He C078400100008 CORRECTION Coorected for background. C078400100009 ERR-ANALYS (DATA-ERR) No information on source of uncertainties. C078400100010 STATUS Data taken from Table I in reference. C078400100011 (APRVD) Approved by J.A. Kuehner, 26 March 2001. C078400100012 HISTORY (20010214C) VM C078400100013 ENDBIB 11 0 C078400100014 COMMON 1 3 C078400100015 E-EXC C078400100016 MEV C078400100017 7.5 C078400100018 ENDCOMMON 3 0 C078400100019 ENDSUBENT 18 0 C078400199999 SUBENT C0784002 20010214 0000C078400200001 BIB 7 9 C078400200002 REACTION (1-H-1(D,G)2-HE-3,,POL/DA,,ANA) C078400200003 FACILITY (VDGT,1CANMCM) C078400200004 INC-SOURCE (LAMB). Average beam polarization (75+-5)%. C078400200005 SAMPLE Polyethylene films. C078400200006 METHOD Polarization determined using quench-ratio method. C078400200007 DETECTOR (MAGSP) Enge split-pole magnetic spectrograph. C078400200008 (SOLST) Position-sensitive surface barrier detectors. C078400200009 MONITOR Beam current monitored using the 12C(d(pol),d)12C(gs) C078400200010 reaction. C078400200011 ENDBIB 9 0 C078400200012 COMMON 1 3 C078400200013 EN C078400200014 MEV C078400200015 6. C078400200016 ENDCOMMON 3 0 C078400200017 DATA 3 7 C078400200018 ANG-CM DATA DATA-ERR C078400200019 ADEG NO-DIM NO-DIM C078400200020 13. -0.057 0.01 C078400200021 40. -0.058 0.007 C078400200022 60. -0.048 0.004 C078400200023 80. -0.042 0.004 C078400200024 110. -0.037 0.006 C078400200025 135. -0.036 0.006 C078400200026 162. -0.014 0.009 C078400200027 ENDDATA 9 0 C078400200028 ENDSUBENT 27 0 C078400299999 SUBENT C0784003 20010214 0000C078400300001 BIB 6 7 C078400300002 REACTION (1-H-2(P,G)2-HE-3,,DA,,REL) C078400300003 FACILITY (VDGT,1USATNL) C078400300004 SAMPLE Deuterium gas cell at a pressure of 82.7 kPa. C078400300005 METHOD (BCINT) C078400300006 DETECTOR (NAICR) 2 large NaI detectors to measure capture C078400300007 gamma rays. C078400300008 STATUS (CURVE) Data read from Fig. 7 in reference. C078400300009 ENDBIB 7 0 C078400300010 COMMON 1 3 C078400300011 EN C078400300012 MEV C078400300013 3. C078400300014 ENDCOMMON 3 0 C078400300015 DATA 3 12 C078400300016 ANG-CM DATA-CM DATA-ERR C078400300017 ADEG ARB-UNITS ARB-UNITS C078400300018 30. 5.6 0.4 C078400300019 50. 8.7 0.8 C078400300020 60. 9.1 1.0 C078400300021 70. 10.5 1.2 C078400300022 80. 10.6 1.0 C078400300023 90. 10.9 1.1 C078400300024 100. 9.6 1.0 C078400300025 110. 8.7 0.9 C078400300026 120. 7.2 0.8 C078400300027 130. 6.0 0.6 C078400300028 140. 3.5 0.4 C078400300029 150. 3.7 0.4 C078400300030 ENDDATA 14 0 C078400300031 ENDSUBENT 30 0 C078400399999 SUBENT C0784004 20010214 0000C078400400001 BIB 6 7 C078400400002 REACTION (1-H-2(P,G)2-HE-3,,POL/DA,,ANA) C078400400003 FACILITY (VDGT,1USATNL) C078400400004 INC-SOURCE (LAMB). Beam polarization 77%. C078400400005 SAMPLE Deuterium gas cell at a pressure of 82.7 kPa. C078400400006 METHOD Polarization determined using quench-ratio method. C078400400007 DETECTOR (NAICR) 2 large NaI detectors to measure capture C078400400008 gamma rays. C078400400009 ENDBIB 7 0 C078400400010 COMMON 1 3 C078400400011 EN C078400400012 MEV C078400400013 3. C078400400014 ENDCOMMON 3 0 C078400400015 DATA 3 4 C078400400016 ANG-CM DATA DATA-ERR C078400400017 ADEG NO-DIM NO-DIM C078400400018 51. 0.060 0.025 C078400400019 92. 0.056 0.027 C078400400020 92. 0.039 0.020 C078400400021 131. 0.050 0.022 C078400400022 ENDDATA 6 0 C078400400023 ENDSUBENT 22 0 C078400499999 ENDENTRY 4 0 C078499999999