ENTRY C0879 20120123 C114C087900000001 SUBENT C0879001 20120123 C114C087900100001 BIB 13 25 C087900100002 INSTITUTE (1USAHRV) C087900100003 REFERENCE (C,2002SANTA,(01-28-02),200204) C087900100004 Proceedings published only on CD-ROM. C087900100005 AUTHOR (J.M.Sisterson) C087900100006 TITLE Selected radiation safety issues at proton therapy C087900100007 facilities C087900100008 FACILITY (SYNCY,1USAHRV) 160 MeV proton synchrocyclotron. C087900100009 SAMPLE 0.0508 cm thick brass target: 60-63% copper, 36.5% C087900100010 zinc, 1.5-2.5% lead, 0.1% iron. C087900100011 METHOD (STTA) Target stack, made up of 3 brass targets, brass C087900100012 spacers, and aluminum monitor foils. C087900100013 (ACTIV) Irradiation time 30 minutes. Each target foil C087900100014 counted 3 times, twice within 1-2 days, once a week C087900100015 later. C087900100016 DETECTOR (GE-IN) High purity Ge detector. C087900100017 MONITOR (13-AL-27(P,X)11-NA-24,,SIG) C087900100018 CORRECTION Corrected for counting geometry. C087900100019 ERR-ANALYS (DATA-ERR) Data uncertainties given include error in: C087900100020 (ERR-1) target weight (2%), C087900100021 (ERR-S) counting efficiency (5%), C087900100022 (ERR-2) number of protons incident on target (5%). C087900100023 STATUS (APRVD) Approved by J. Sisterson, 10 June 2002. C087900100024 Data taken from reference. C087900100025 HISTORY (20020515C) VM C087900100026 (20120123U) SD: page to ref. added. C087900100027 ENDBIB 25 0 C087900100028 COMMON 3 3 C087900100029 ERR-1 ERR-2 ERR-S C087900100030 PER-CENT PER-CENT PER-CENT C087900100031 2. 5. 5. C087900100032 ENDCOMMON 3 0 C087900100033 ENDSUBENT 32 0 C087900199999 SUBENT C0879002 20020612 0000C087900200001 BIB 2 2 C087900200002 REACTION (29-CU-CMP(P,X)24-CR-51,,SIG) Brass C087900200003 DECAY-DATA (24-CR-51,27.7D,DG) C087900200004 ENDBIB 2 0 C087900200005 NOCOMMON 0 0 C087900200006 DATA 3 3 C087900200007 EN DATA DATA-ERR C087900200008 MEV MB MB C087900200009 70. 0.0 C087900200010 120. 4.3 0.4 C087900200011 160. 7.9 0.7 C087900200012 ENDDATA 5 0 C087900200013 ENDSUBENT 12 0 C087900299999 SUBENT C0879003 20020612 0000C087900300001 BIB 2 2 C087900300002 REACTION (29-CU-CMP(P,X)25-MN-52,,SIG) Brass C087900300003 DECAY-DATA (25-MN-52-G,5.591D,DG) C087900300004 ENDBIB 2 0 C087900300005 NOCOMMON 0 0 C087900300006 DATA 3 3 C087900300007 EN DATA DATA-ERR C087900300008 MEV MB MB C087900300009 70. 0.08 0.01 C087900300010 120. 2.0 0.1 C087900300011 160. 3.8 0.3 C087900300012 ENDDATA 5 0 C087900300013 ENDSUBENT 12 0 C087900399999 SUBENT C0879004 20020612 0000C087900400001 BIB 2 2 C087900400002 REACTION (29-CU-CMP(P,X)25-MN-54,,SIG) Brass C087900400003 DECAY-DATA (25-MN-54,312.3D,DG) C087900400004 ENDBIB 2 0 C087900400005 NOCOMMON 0 0 C087900400006 DATA 3 3 C087900400007 EN DATA DATA-ERR C087900400008 MEV MB MB C087900400009 70. 2.7 0.3 C087900400010 120. 8.8 0.7 C087900400011 160. 13.6 1.1 C087900400012 ENDDATA 5 0 C087900400013 ENDSUBENT 12 0 C087900499999 SUBENT C0879005 20020612 0000C087900500001 BIB 2 2 C087900500002 REACTION (29-CU-CMP(P,X)27-CO-56,,SIG) Brass C087900500003 DECAY-DATA (27-CO-56,77.3D,DG) C087900500004 ENDBIB 2 0 C087900500005 NOCOMMON 0 0 C087900500006 DATA 3 3 C087900500007 EN DATA DATA-ERR C087900500008 MEV MB MB C087900500009 70. 6.8 0.5 C087900500010 120. 11.1 0.8 C087900500011 160. 11.8 0.9 C087900500012 ENDDATA 5 0 C087900500013 ENDSUBENT 12 0 C087900599999 SUBENT C0879006 20020612 0000C087900600001 BIB 2 2 C087900600002 REACTION (29-CU-CMP(P,X)28-NI-56,,SIG) Brass C087900600003 DECAY-DATA (28-NI-56,77.27D,DG) C087900600004 ENDBIB 2 0 C087900600005 NOCOMMON 0 0 C087900600006 DATA 3 3 C087900600007 EN DATA DATA-ERR C087900600008 MEV MB MB C087900600009 70. 0.05 0.004 C087900600010 120. 0.1 0.01 C087900600011 160. 0.1 0.01 C087900600012 ENDDATA 5 0 C087900600013 ENDSUBENT 12 0 C087900699999 SUBENT C0879007 20020612 0000C087900700001 BIB 2 2 C087900700002 REACTION (29-CU-CMP(P,X)27-CO-57,,SIG) Brass C087900700003 DECAY-DATA (27-CO-57,271.8D,DG) C087900700004 ENDBIB 2 0 C087900700005 NOCOMMON 0 0 C087900700006 DATA 3 3 C087900700007 EN DATA DATA-ERR C087900700008 MEV MB MB C087900700009 70. 28.6 2.1 C087900700010 120. 37.9 2.8 C087900700011 160. 38.6 2.9 C087900700012 ENDDATA 5 0 C087900700013 ENDSUBENT 12 0 C087900799999 SUBENT C0879008 20020612 0000C087900800001 BIB 2 2 C087900800002 REACTION (29-CU-CMP(P,X)28-NI-57,,SIG) Brass C087900800003 DECAY-DATA (28-NI-57,35.6HR,DG) C087900800004 ENDBIB 2 0 C087900800005 NOCOMMON 0 0 C087900800006 DATA 3 3 C087900800007 EN DATA DATA-ERR C087900800008 MEV MB MB C087900800009 70. 1.2 0.2 C087900800010 120. 1.4 0.2 C087900800011 160. 2.0 0.2 C087900800012 ENDDATA 5 0 C087900800013 ENDSUBENT 12 0 C087900899999 SUBENT C0879009 20020612 0000C087900900001 BIB 2 2 C087900900002 REACTION (29-CU-CMP(P,X)27-CO-58,,SIG) Brass C087900900003 DECAY-DATA (27-CO-58-G,70.8D,DG) C087900900004 ENDBIB 2 0 C087900900005 NOCOMMON 0 0 C087900900006 DATA 3 3 C087900900007 EN DATA DATA-ERR C087900900008 MEV MB MB C087900900009 70. 29.6 2.2 C087900900010 120. 43.8 3.2 C087900900011 160. 44.3 3.3 C087900900012 ENDDATA 5 0 C087900900013 ENDSUBENT 12 0 C087900999999 SUBENT C0879010 20020612 0000C087901000001 BIB 3 4 C087901000002 REACTION (29-CU-CMP(P,X)26-FE-59,,SIG) Brass C087901000003 DECAY-DATA (26-FE-59,44.503D,DG) C087901000004 STATUS Data updated to current half-life by J. Sisterson, C087901000005 10 June 2002. C087901000006 ENDBIB 4 0 C087901000007 NOCOMMON 0 0 C087901000008 DATA 3 3 C087901000009 EN DATA DATA-ERR C087901000010 MEV MB MB C087901000011 70. 0.6 0.09 C087901000012 120. 1.0 0.1 C087901000013 160. 1.2 0.2 C087901000014 ENDDATA 5 0 C087901000015 ENDSUBENT 14 0 C087901099999 SUBENT C0879011 20020612 0000C087901100001 BIB 2 2 C087901100002 REACTION (29-CU-CMP(P,X)27-CO-60,,SIG) Brass C087901100003 DECAY-DATA (27-CO-60-G,1924.1D,DG) C087901100004 ENDBIB 2 0 C087901100005 NOCOMMON 0 0 C087901100006 DATA 3 3 C087901100007 EN DATA DATA-ERR C087901100008 MEV MB MB C087901100009 70. 9.5 2.3 C087901100010 120. 15.1 2.5 C087901100011 160. 27.8 4.0 C087901100012 ENDDATA 5 0 C087901100013 ENDSUBENT 12 0 C087901199999 SUBENT C0879012 20020612 0000C087901200001 BIB 2 2 C087901200002 REACTION (29-CU-CMP(P,X)30-ZN-62,,SIG) Brass C087901200003 DECAY-DATA (30-ZN-62,9.186HR,DG) C087901200004 ENDBIB 2 0 C087901200005 NOCOMMON 0 0 C087901200006 DATA 3 3 C087901200007 EN DATA DATA-ERR C087901200008 MEV MB MB C087901200009 70. 10.2 0.8 C087901200010 120. 10.2 0.8 C087901200011 160. 6.1 0.5 C087901200012 ENDDATA 5 0 C087901200013 ENDSUBENT 12 0 C087901299999 SUBENT C0879013 20020612 0000C087901300001 BIB 2 2 C087901300002 REACTION (29-CU-CMP(P,X)30-ZN-65,,SIG) Brass C087901300003 DECAY-DATA (30-ZN-65,244.3D,DG) C087901300004 ENDBIB 2 0 C087901300005 NOCOMMON 0 0 C087901300006 DATA 3 3 C087901300007 EN DATA DATA-ERR C087901300008 MEV MB MB C087901300009 70. 34.8 2.7 C087901300010 120. 24.8 2.0 C087901300011 160. 19.1 1.6 C087901300012 ENDDATA 5 0 C087901300013 ENDSUBENT 12 0 C087901399999 SUBENT C0879014 20020612 0000C087901400001 BIB 2 2 C087901400002 REACTION (29-CU-CMP(P,X)82-PB-201,,SIG) Brass C087901400003 DECAY-DATA (82-PB-201-G,9.33HR,DG) C087901400004 ENDBIB 2 0 C087901400005 NOCOMMON 0 0 C087901400006 DATA 3 3 C087901400007 EN DATA DATA-ERR C087901400008 MEV MB MB C087901400009 70. 4.6 0.4 C087901400010 120. 4.6 0.4 C087901400011 160. 3.4 0.3 C087901400012 ENDDATA 5 0 C087901400013 ENDSUBENT 12 0 C087901499999 SUBENT C0879015 20020612 0000C087901500001 BIB 2 2 C087901500002 REACTION (29-CU-CMP(P,X)83-BI-203,,SIG) Brass C087901500003 DECAY-DATA (83-BI-203-G,11.76HR,DG) C087901500004 ENDBIB 2 0 C087901500005 NOCOMMON 0 0 C087901500006 DATA 3 3 C087901500007 EN DATA DATA-ERR C087901500008 MEV MB MB C087901500009 70. 0.2 0.03 C087901500010 120. 0.2 0.03 C087901500011 160. 0.1 0.03 C087901500012 ENDDATA 5 0 C087901500013 ENDSUBENT 12 0 C087901599999 SUBENT C0879016 20020612 0000C087901600001 BIB 2 2 C087901600002 REACTION (29-CU-CMP(P,X)83-BI-204,,SIG) Brass C087901600003 DECAY-DATA (83-BI-204,11.22HR,DG) C087901600004 ENDBIB 2 0 C087901600005 NOCOMMON 0 0 C087901600006 DATA 3 3 C087901600007 EN DATA DATA-ERR C087901600008 MEV MB MB C087901600009 70. 0.7 0.08 C087901600010 120. 0.3 0.06 C087901600011 160. 0.1 0.01 C087901600012 ENDDATA 5 0 C087901600013 ENDSUBENT 12 0 C087901699999 SUBENT C0879017 20020612 0000C087901700001 BIB 2 2 C087901700002 REACTION (29-CU-CMP(P,X)83-BI-206,,SIG) Brass C087901700003 DECAY-DATA (83-BI-206,6.243D,DG) C087901700004 ENDBIB 2 0 C087901700005 NOCOMMON 0 0 C087901700006 DATA 3 3 C087901700007 EN DATA DATA-ERR C087901700008 MEV MB MB C087901700009 70. 0.3 0.03 C087901700010 120. 0.2 0.02 C087901700011 160. 0.1 0.02 C087901700012 ENDDATA 5 0 C087901700013 ENDSUBENT 12 0 C087901799999 ENDENTRY 17 0 C087999999999