ENTRY C0950 20040107 0000C095000000001 SUBENT C0950001 20040107 0000C095000100001 BIB 9 15 C095000100002 INSTITUTE (1USALAS,1USABNL,1USAUSA,1USALRL) Bechtel Nevada, C095000100003 Las Vegas. C095000100004 REFERENCE (J,NIM/B,211,297,2003) C095000100005 AUTHOR (G.L.Morgan,K.R.Alrick,A.Saunders,F.C.Cverna, C095000100006 N.S.P.King,F.E.Merrill,L.S.Waters,A.L.Hanson, C095000100007 G.A.Greene,R.P.Liljestrand,R.T.Thompson,E.A.Henry) C095000100008 TITLE Total cross sectionsfor the production of 22Na and C095000100009 24Na in proton-induced reactions on 27Al from 0.40 to C095000100010 22.4 GeV C095000100011 FACILITY (MESON,1USALAS) LANSCE facility at 0.4 and 0.8 GeV. C095000100012 (SYNCH,1USABNL) AGS above 0.8 GeV. C095000100013 SAMPLE Stack of 3 Al foils, each about 80 mg/cm2 thick. C095000100014 MONITOR LANSCE data were normalized to AGS data at 0.8 GeV. C095000100015 STATUS Data taken from tables in reference. C095000100016 HISTORY (20040107C) VM C095000100017 ENDBIB 15 0 C095000100018 NOCOMMON 0 0 C095000100019 ENDSUBENT 18 0 C095000199999 SUBENT C0950002 20040107 0000C095000200001 BIB 8 16 C095000200002 REACTION (13-AL-27(P,X)11-NA-22,,SIG) C095000200003 DETECTOR (NAICR) 2 NaI crystals face-to-face with the Al foil C095000200004 centered between them and in coincidence with each C095000200005 other. C095000200006 DECAY-DATA (11-NA-22,2.6019YR,DG,1275.,1.0) C095000200007 MONITOR Detector efficiency determined using calibrated 22Na C095000200008 source. C095000200009 ANALYSIS Where there is more than one irradiation at a given C095000200010 energy, the data are a weighted average. C095000200011 CORRECTION Corrected for: C095000200012 . background, C095000200013 . decay during irradiation, between irradiation and C095000200014 counting, and during counting. C095000200015 ERR-ANALYS (DATA-ERR) Overall uncertainty, includes random and C095000200016 systematic uncertainties. C095000200017 MISC-COL (MISC) Number of irradiations. C095000200018 ENDBIB 16 0 C095000200019 NOCOMMON 0 0 C095000200020 DATA 4 6 C095000200021 EN DATA DATA-ERR MISC C095000200022 GEV MB PER-CENT NO-DIM C095000200023 0.40 14.97 2.6 2. C095000200024 0.81 14.30 2.6 1. C095000200025 1.60 12.90 2.6 3. C095000200026 2.00 12.18 2.6 2. C095000200027 7.00 10.89 2.9 1. C095000200028 22.4 10.32 2.9 1. C095000200029 ENDDATA 8 0 C095000200030 ENDSUBENT 29 0 C095000299999 SUBENT C0950003 20040107 0000C095000300001 BIB 5 15 C095000300002 REACTION (13-AL-27(P,X)11-NA-24,,SIG) C095000300003 DETECTOR (GE-IN) Shielded Ge detectors. C095000300004 DECAY-DATA (11-NA-24,14.959HR,DG,1368.) C095000300005 MONITOR Detector efficiency determined using calibrated 60Co C095000300006 source. C095000300007 CORRECTION Corrected for: C095000300008 . background, C095000300009 . decay during irradiation, between irradiation and C095000300010 counting, and during counting, C095000300011 . energy dependence of detector efficiency, C095000300012 . geometrical differences between point calibration C095000300013 source and the finite activation spot on Al foil, C095000300014 . difference in gamma-ray absorption in target, C095000300015 . difference in distance between foil and 60Co C095000300016 calibration source. C095000300017 ENDBIB 15 0 C095000300018 NOCOMMON 0 0 C095000300019 DATA 3 6 C095000300020 EN DATA DATA-ERR C095000300021 GEV MB PER-CENT C095000300022 0.40 10.07 2.0 C095000300023 0.81 10.70 1.2 C095000300024 1.60 10.18 1.1 C095000300025 2.00 9.75 1.1 C095000300026 7.00 8.94 1.6 C095000300027 22.4 8.78 1.6 C095000300028 ENDDATA 8 0 C095000300029 ENDSUBENT 28 0 C095000399999 ENDENTRY 3 0 C095099999999