ENTRY C1027 20040420 0000C102700000001 SUBENT C1027001 20040420 0000C102700100001 BIB 7 8 C102700100002 INSTITUTE (1USALRC,1USATAM) C102700100003 REFERENCE (J,MED,5,532,1978) C102700100004 AUTHOR (J.W.Blue,D.C.Liu,J.B.Smathers) C102700100005 TITLE Thallium-201 production with the idle beam from C102700100006 neutron therapy C102700100007 METHOD (ACTIV) C102700100008 DETECTOR (GELI) C102700100009 HISTORY (20040420C) VM C102700100010 ENDBIB 8 0 C102700100011 NOCOMMON 0 0 C102700100012 ENDSUBENT 11 0 C102700199999 SUBENT C1027002 20040420 0000C102700200001 BIB 7 9 C102700200002 REACTION (81-TL-203(P,3N)82-PB-201,,SIG) C102700200003 FACILITY (CYCLO,1USALRC) Incident beam energy 37 MeV. C102700200004 SAMPLE Stacks containing natural thallium metal foil targets C102700200005 separated by aluminum foils. C102700200006 METHOD (BCINT) C102700200007 DECAY-DATA (82-PB-201-G,9.4HR,DG,331.,0.82) C102700200008 ERR-ANALYS (EN-ERR-DIG) Digitizing error C102700200009 (ERR-DIG) Digitizing error C102700200010 STATUS (CURVE) Scanned from Fig.1 in reference at IAEA-NDS. C102700200011 ENDBIB 9 0 C102700200012 COMMON 2 3 C102700200013 EN-ERR-DIG ERR-DIG C102700200014 MEV PER-CENT C102700200015 0.05 0.2 C102700200016 ENDCOMMON 3 0 C102700200017 DATA 2 12 C102700200018 EN DATA C102700200019 MEV MB C102700200020 18.47 8.66 C102700200021 20.19 100.7 C102700200022 21.90 313.8 C102700200023 23.52 463.7 C102700200024 25.07 581.7 C102700200025 26.57 615.9 C102700200026 27.96 659.4 C102700200027 29.23 671.1 C102700200028 30.47 589.5 C102700200029 31.73 492.3 C102700200030 32.94 348.9 C102700200031 35.19 270.8 C102700200032 ENDDATA 14 0 C102700200033 ENDSUBENT 32 0 C102700299999 SUBENT C1027003 20040420 0000C102700300001 BIB 7 9 C102700300002 REACTION (81-TL-203(P,4N)82-PB-200,,SIG) C102700300003 FACILITY (CYCLO,1USALRC) Incident beam energy 37 MeV. C102700300004 SAMPLE Stacks containing natural thallium metal foil targets C102700300005 separated by aluminum foils. C102700300006 METHOD (BCINT) C102700300007 DECAY-DATA (82-PB-200,21.5HR,DG,368.) C102700300008 ERR-ANALYS (EN-ERR-DIG) Digitizing error C102700300009 (ERR-DIG) Digitizing error C102700300010 STATUS (CURVE) Scanned from Fig.1 in reference at IAEA-NDS. C102700300011 ENDBIB 9 0 C102700300012 COMMON 2 3 C102700300013 EN-ERR-DIG ERR-DIG C102700300014 MEV PER-CENT C102700300015 0.05 0.2 C102700300016 ENDCOMMON 3 0 C102700300017 DATA 2 6 C102700300018 EN DATA C102700300019 MEV MB C102700300020 27.91 24.04 C102700300021 29.22 74.91 C102700300022 30.41 213.2 C102700300023 31.71 344.8 C102700300024 32.93 570.4 C102700300025 35.10 1028. C102700300026 ENDDATA 8 0 C102700300027 ENDSUBENT 26 0 C102700399999 SUBENT C1027004 20040420 0000C102700400001 BIB 7 9 C102700400002 REACTION (81-TL-203(P,4N)82-PB-200,,SIG) C102700400003 FACILITY (CYCLO,1USALRC) Incident beam energy 37 MeV. C102700400004 SAMPLE Stacks containing natural thallium metal foil targets C102700400005 separated by aluminum foils. C102700400006 METHOD (BCINT) C102700400007 DECAY-DATA (82-PB-200,21.5HR,DG,579.) C102700400008 ERR-ANALYS (EN-ERR-DIG) Digitizing error C102700400009 (ERR-DIG) Digitizing error C102700400010 STATUS (CURVE) Scanned from Fig.1 in reference at IAEA-NDS. C102700400011 ENDBIB 9 0 C102700400012 COMMON 2 3 C102700400013 EN-ERR-DIG ERR-DIG C102700400014 MEV PER-CENT C102700400015 0.05 0.2 C102700400016 ENDCOMMON 3 0 C102700400017 DATA 2 6 C102700400018 EN DATA C102700400019 MEV MB C102700400020 27.91 18.44 C102700400021 29.23 68.43 C102700400022 30.42 184.1 C102700400023 31.67 333.3 C102700400024 32.97 468.1 C102700400025 35.11 954.8 C102700400026 ENDDATA 8 0 C102700400027 ENDSUBENT 26 0 C102700499999 SUBENT C1027005 20040420 0000C102700500001 BIB 9 19 C102700500002 REACTION (81-TL-203(D,3N)82-PB-202-M,,SIG) C102700500003 FACILITY (CYCLO,1USATAM) Incident beam energy 49 MeV. C102700500004 INC-SPECT For one of target stacks, beryllium plate used to C102700500005 degrade incident beam energy to 37 MeV. C102700500006 SAMPLE Two stacks each containing: C102700500007 . 8 natural thallium metal foil targets; thallium C102700500008 foils separated by carbon foils. Thallium thickness C102700500009 109-147 mg/cm2. C102700500010 . 2 layers of Tl2O3, enriched to 92% 203Tl, and C102700500011 sandwiched between 2 aluminum foils; 203Tl thickness C102700500012 9.5 mg/cm2. C102700500013 DECAY-DATA (82-PB-202-M,3.6HR,DG,422.,0.90) C102700500014 MONITOR (79-AU-197(D,2N)80-HG-197-M,,SIG) C102700500015 Thin gold foil used to monitor beam current. C102700500016 FLAG (1.) Natural Tl foils. C102700500017 (2.) Foils enriched in 203Tl. C102700500018 ERR-ANALYS (EN-ERR-DIG) Digitizing error C102700500019 (ERR-DIG) Digitizing error C102700500020 STATUS (CURVE) Scanned from Fig.2 in reference at IAEA-NDS. C102700500021 ENDBIB 19 0 C102700500022 COMMON 2 3 C102700500023 EN-ERR-DIG ERR-DIG C102700500024 MEV PER-CENT C102700500025 0.05 0.2 C102700500026 ENDCOMMON 3 0 C102700500027 DATA 3 11 C102700500028 EN DATA FLAG C102700500029 MEV MB NO-DIM C102700500030 18.81 113.5 2. C102700500031 19.58 157.7 1. C102700500032 20.57 257.1 1. C102700500033 22.81 333.3 1. C102700500034 23.71 362.2 1. C102700500035 25.92 340.7 1. C102700500036 27.98 243.8 1. C102700500037 30.13 168.0 1. C102700500038 35.37 61.70 2. C102700500039 37.25 61.46 2. C102700500040 48.37 47.45 2. C102700500041 ENDDATA 13 0 C102700500042 ENDSUBENT 41 0 C102700599999 SUBENT C1027006 20040420 0000C102700600001 BIB 9 19 C102700600002 REACTION (81-TL-203(D,4N)82-PB-201,,SIG) C102700600003 FACILITY (CYCLO,1USATAM) Incident beam energy 49 MeV. C102700600004 INC-SPECT For one of target stacks, beryllium plate used to C102700600005 degrade incident beam energy to 37 MeV. C102700600006 SAMPLE Two stacks each containing: C102700600007 . 8 natural thallium metal foil targets; thallium C102700600008 foils separated by carbon foils. Thallium thickness C102700600009 109-147 mg/cm2. C102700600010 . 2 layers of Tl2O3, enriched to 92% 203Tl, and C102700600011 sandwiched between 2 aluminum foils; 203Tl thickness C102700600012 9.5 mg/cm2. C102700600013 DECAY-DATA (82-PB-201-G,9.4HR,DG,331.,0.82) C102700600014 MONITOR (79-AU-197(D,2N)80-HG-197-M,,SIG) C102700600015 Thin gold foil used to monitor beam current. C102700600016 ERR-ANALYS (EN-ERR-DIG) Digitizing error C102700600017 (ERR-DIG) Digitizing error C102700600018 FLAG (1.) Natural Tl foils. C102700600019 (2.) Foils enriched in 203Tl. C102700600020 STATUS (CURVE) Scanned from Fig.2 in reference at IAEA-NDS. C102700600021 ENDBIB 19 0 C102700600022 COMMON 2 3 C102700600023 EN-ERR-DIG ERR-DIG C102700600024 MEV PER-CENT C102700600025 0.05 0.2 C102700600026 ENDCOMMON 3 0 C102700600027 DATA 3 13 C102700600028 EN DATA FLAG C102700600029 MEV MB NO-DIM C102700600030 23.69 129.5 1. C102700600031 25.87 452.3 1. C102700600032 28.00 808.4 1. C102700600033 30.13 1058. 1. C102700600034 32.21 1169. 1. C102700600035 34.22 1164. 1. C102700600036 34.25 1090. 1. C102700600037 35.34 917.4 2. C102700600038 36.22 833.3 1. C102700600039 36.22 996.9 1. C102700600040 36.22 1055. 1. C102700600041 37.29 609.0 2. C102700600042 48.41 344.3 2. C102700600043 ENDDATA 15 0 C102700600044 ENDSUBENT 43 0 C102700699999 SUBENT C1027007 20040420 0000C102700700001 BIB 9 19 C102700700002 REACTION (81-TL-203(D,5N)82-PB-200,,SIG) C102700700003 FACILITY (CYCLO,1USATAM) Incident beam energy 49 MeV. C102700700004 INC-SPECT For one of target stacks, beryllium plate used to C102700700005 degrade incident beam energy to 37 MeV. C102700700006 SAMPLE Two stacks each containing: C102700700007 . 8 natural thallium metal foil targets; thallium C102700700008 foils separated by carbon foils. Thallium thickness C102700700009 109-147 mg/cm2. C102700700010 . 2 layers of Tl2O3, enriched to 92% 203Tl, and C102700700011 sandwiched between 2 aluminum foils; 203Tl thickness C102700700012 9.5 mg/cm2. C102700700013 DECAY-DATA (82-PB-200,21.5HR,DG,148.,0.17) C102700700014 MONITOR (79-AU-197(D,2N)80-HG-197-M,,SIG) C102700700015 Thin gold foil used to monitor beam current. C102700700016 ERR-ANALYS (EN-ERR-DIG) Digitizing error C102700700017 (ERR-DIG) Digitizing error C102700700018 FLAG (1.) Natural Tl foils. C102700700019 (2.) Foils enriched in 203Tl. C102700700020 STATUS (CURVE) Scanned from Fig.2 in reference at IAEA-NDS. C102700700021 ENDBIB 19 0 C102700700022 COMMON 2 3 C102700700023 EN-ERR-DIG ERR-DIG C102700700024 MEV PER-CENT C102700700025 0.05 0.2 C102700700026 ENDCOMMON 3 0 C102700700027 DATA 3 13 C102700700028 EN DATA FLAG C102700700029 MEV MB NO-DIM C102700700030 34.25 209.0 1. C102700700031 35.32 367.3 2. C102700700032 36.26 696.5 1. C102700700033 36.26 610.3 1. C102700700034 37.27 742.5 2. C102700700035 37.85 1042. 1. C102700700036 39.43 1266. 1. C102700700037 41.07 1538. 1. C102700700038 42.60 1623. 1. C102700700039 44.29 1617. 1. C102700700040 46.00 1494. 1. C102700700041 47.58 1305. 1. C102700700042 48.48 1327. 2. C102700700043 ENDDATA 15 0 C102700700044 ENDSUBENT 43 0 C102700799999 SUBENT C1027008 20040420 0000C102700800001 BIB 8 13 C102700800002 REACTION (81-TL-205(D,3N)82-PB-204-M,,SIG) C102700800003 FACILITY (CYCLO,1USATAM) Incident beam energy 49 MeV. C102700800004 INC-SPECT For one of target stacks, beryllium plate used to C102700800005 degrade incident beam energy to 37 MeV. C102700800006 SAMPLE Two stacks each containing 8 natural thallium metal C102700800007 foil targets; thallium foils separated by carbon C102700800008 foils. Thallium thickness 109-147 mg/cm2. C102700800009 DECAY-DATA (82-PB-204-M,1.1HR,DG,375.,0.93) C102700800010 MONITOR (79-AU-197(D,2N)80-HG-197-M,,SIG) C102700800011 Thin gold foil used to monitor beam current. C102700800012 ERR-ANALYS (EN-ERR-DIG) Digitizing error C102700800013 (ERR-DIG) Digitizing error C102700800014 STATUS (CURVE) Scanned from Fig.3 in reference at IAEA-NDS. C102700800015 ENDBIB 13 0 C102700800016 COMMON 2 3 C102700800017 EN-ERR-DIG ERR-DIG C102700800018 MEV PER-CENT C102700800019 0.05 0.2 C102700800020 ENDCOMMON 3 0 C102700800021 DATA 2 10 C102700800022 EN DATA C102700800023 MEV MB C102700800024 19.57 284.9 C102700800025 20.62 424.6 C102700800026 22.78 434.3 C102700800027 23.65 414.6 C102700800028 25.88 327.4 C102700800029 27.98 210.7 C102700800030 30.08 125.1 C102700800031 32.20 90.40 C102700800032 34.21 80.92 C102700800033 36.26 62.24 C102700800034 ENDDATA 12 0 C102700800035 ENDSUBENT 34 0 C102700899999 SUBENT C1027009 20040420 0000C102700900001 BIB 8 13 C102700900002 REACTION (81-TL-205(D,4N)82-PB-203,,SIG) C102700900003 FACILITY (CYCLO,1USATAM) Incident beam energy 49 MeV. C102700900004 INC-SPECT For one of target stacks, beryllium plate used to C102700900005 degrade incident beam energy to 37 MeV. C102700900006 SAMPLE Two stacks each containing 8 natural thallium metal C102700900007 foil targets; thallium foils separated by carbon C102700900008 foils. Thallium thickness 109-147 mg/cm2. C102700900009 DECAY-DATA (82-PB-203-G,52.1HR,DG,279.,0.81) C102700900010 MONITOR (79-AU-197(D,2N)80-HG-197-M,,SIG) C102700900011 Thin gold foil used to monitor beam current. C102700900012 ERR-ANALYS (EN-ERR-DIG) Digitizing error C102700900013 (ERR-DIG) Digitizing error C102700900014 STATUS (CURVE) Scanned from Fig.3 in reference at IAEA-NDS. C102700900015 ENDBIB 13 0 C102700900016 COMMON 2 3 C102700900017 EN-ERR-DIG ERR-DIG C102700900018 MEV PER-CENT C102700900019 0.05 0.2 C102700900020 ENDCOMMON 3 0 C102700900021 DATA 2 14 C102700900022 EN DATA C102700900023 MEV MB C102700900024 23.65 425.9 C102700900025 25.85 820.2 C102700900026 27.98 1106. C102700900027 30.06 1248. C102700900028 32.20 1210. C102700900029 34.22 973.1 C102700900030 36.20 918.9 C102700900031 36.22 796.7 C102700900032 37.81 766.4 C102700900033 39.40 616.9 C102700900034 42.53 486.3 C102700900035 44.19 431.7 C102700900036 45.86 407.9 C102700900037 47.48 349.5 C102700900038 ENDDATA 16 0 C102700900039 ENDSUBENT 38 0 C102700999999 SUBENT C1027010 20040420 0000C102701000001 BIB 8 13 C102701000002 REACTION (81-TL-205(D,5N)82-PB-202-M,,SIG) C102701000003 FACILITY (CYCLO,1USATAM) Incident beam energy 49 MeV. C102701000004 INC-SPECT For one of target stacks, beryllium plate used to C102701000005 degrade incident beam energy to 37 MeV. C102701000006 SAMPLE Two stacks each containing 8 natural thallium metal C102701000007 foil targets; thallium foils separated by carbon C102701000008 foils. Thallium thickness 109-147 mg/cm2. C102701000009 DECAY-DATA (82-PB-202-M,3.6HR,DG,422.,0.90) C102701000010 MONITOR (79-AU-197(D,2N)80-HG-197-M,,SIG) C102701000011 Thin gold foil used to monitor beam current. C102701000012 ERR-ANALYS (EN-ERR-DIG) Digitizing error C102701000013 (ERR-DIG) Digitizing error C102701000014 STATUS (CURVE) Scanned from Fig.3 in reference at IAEA-NDS. C102701000015 ENDBIB 13 0 C102701000016 COMMON 2 3 C102701000017 EN-ERR-DIG ERR-DIG C102701000018 MEV PER-CENT C102701000019 0.05 0.2 C102701000020 ENDCOMMON 3 0 C102701000021 DATA 2 10 C102701000022 EN DATA C102701000023 MEV MB C102701000024 32.20 87.24 C102701000025 34.19 168.1 C102701000026 36.25 278.3 C102701000027 37.80 362.5 C102701000028 39.42 413.0 C102701000029 41.01 454.2 C102701000030 42.53 461.0 C102701000031 44.19 427.9 C102701000032 45.91 363.3 C102701000033 47.50 303.0 C102701000034 ENDDATA 12 0 C102701000035 ENDSUBENT 34 0 C102701099999 ENDENTRY 10 0 C102799999999