ENTRY C1449 20081020 C089C144900000001 SUBENT C1449001 20081020 C089C144900100001 BIB 10 35 C144900100002 INSTITUTE (1CANTMF,1CANMCM,1USACSM,1CANSFU,2EIREIR,2GERLMU, C144900100003 1CANCAN,2BLGLEU) + University de Catalunya, Spain + C144900100004 University of York, UK C144900100005 REFERENCE (J,PRL,96,252501,2006) C144900100006 AUTHOR (C.Ruiz,A.Parikh,J.Jose,L.Buchmann,J.A.Caggiano, C144900100007 A.A.Chen,J.A.Clark,H.Crawford,B.Davids,J.M.D'Auria, C144900100008 C.Davis,C.Deibel,L.Erikson,L.Fogarty,D.Frekers, C144900100009 U.Greife,A.Hussein,D.A.Hutcheon,M.Huyse,C.Jewett, C144900100010 A.M.Laird,R.Lewis,P.Mumby-Croft,A.Olin,D.F.Ottewell, C144900100011 C.V.Ouellet,P.Parker,J.Pearson,G.Ruprecht,M.Trinczek, C144900100012 C.Vockenhuber,C.Wrede) C144900100013 TITLE Measurement of the E(c.m.)=184 keV Resonance Strength C144900100014 in the 26gAl(p,gamma)27Si Reaction C144900100015 FACILITY (FRS,1CANTMF) the DRAGON recoil separator in the ISAC C144900100016 radioactive ion beam facility at TRIUMF. C144900100017 INC-SOURCE A high-power SiC target was bombarded with up to 70 C144900100018 microA of 500 MeV protons from TRIUMF's sector C144900100019 focussing cyclotron, producing radioactive 26gAl C144900100020 DETECTOR (BGO) The DRAGON facility consists of a windowless C144900100021 hydrogen-recirculating gas target surrounded by an C144900100022 array of 30 bismuth germanate (BGO) detectors, and a C144900100023 two-stage electromagnetic recoil separator. C144900100024 (SIBAR) The total separator length from the center of C144900100025 the gas cell to the final m=q focus is 20.42 m, with C144900100026 a double-sided silicon strip detector (DSSD) placed C144900100027 65 cm downstream from the focus. A collimated silicon C144900100028 surface barrier detector placed at 30 degree from the C144900100029 center of the gas cell was used to detect protons C144900100030 elastically scattered by the incoming beam during the C144900100031 run as a means of normalization. C144900100032 SAMPLE A gas-target pressure of 6 Torr was maintained to C144900100033 within +/- 1.6%. C144900100034 METHOD (COINC) C144900100035 HISTORY (20060718C) DR C144900100036 (20081020A) BIB update. C144900100037 ENDBIB 35 0 C144900100038 NOCOMMON 0 0 C144900100039 ENDSUBENT 38 0 C144900199999 SUBENT C1449002 20081020 C089C144900200001 BIB 4 5 C144900200002 REACTION (13-AL-26(P,G),,WID/STR) C144900200003 ERR-ANALYS (ERR-S) Statistical error C144900200004 (ERR-SYS) Systematical error C144900200005 STATUS (TABLE) Data taken from Table 1 C144900200006 HISTORY (20081020A) Target nucleus corrected. C144900200007 ENDBIB 5 0 C144900200008 NOCOMMON 0 0 C144900200009 DATA 4 2 C144900200010 EN-RES DATA ERR-S ERR-SYS C144900200011 MEV MICRO-EV MICRO-EV MICRO-EV C144900200012 5.226 35. 4. 5. C144900200013 5.122 36. 8. 6. C144900200014 ENDDATA 4 0 C144900200015 ENDSUBENT 14 0 C144900299999 ENDENTRY 2 0 C144999999999