ENTRY C1502 20181107 C181C150200000001 SUBENT C1502001 20181107 C181C150200100001 BIB 9 29 C150200100002 INSTITUTE (2UK BIR,1USAFSU,2UK SUR) C150200100003 REFERENCE (J,PR/C,73,057301,2006) C150200100004 AUTHOR (N.Curtis,N.I.Ashwood,L.T.Baby,T.D.Baldwin, C150200100005 T.R.Bloxham,W.N.Catford,D.D.Caussyn,M.Freer, C150200100006 C.W.Harlin,P.McEwan,D.L.Price,D.Spingler, C150200100007 I.Wiedenhover) C150200100008 TITLE Alpha-decaying states in 10,12Be populated in the C150200100009 10Be(14C,10,12Be) reaction C150200100010 FACILITY (LINAC,1USAFSU) the Florida State University C150200100011 superconducting LINAC facility. C150200100012 INC-SPECT The 14C beam was not debunched following LINAC. The C150200100013 integrated beam exposure was 0.44 mC. C150200100014 SAMPLE The reaction target, 280 microg/cm2 BeO, was mounted onC150200100015 a 1.0 mg/cm2 Pt backing for mechanical support. The C150200100016 10Be enrichment was about 94% and the total 10Be C150200100017 thickness about 100 microg/cm2. The target was C150200100018 orientated with the Pt backing upstream and the BeO C150200100019 facing the detectors. C150200100020 DETECTOR (TELES,SI,SI) An array of two (50 mm x 50 mm) detector C150200100021 telescopes. The first element in each telescope was C150200100022 a 65 microm thick silicon double sided strip detector C150200100023 (DSSD) used for energy loss (DE) measurements. Each C150200100024 DSSD was segmented into 32 independent (50 mm x 3 mm) C150200100025 strips, with 16 horizontal strips on the front face C150200100026 and 16 vertical strips on the back face. The second C150200100027 element was a 500 microm thick silicon resistive C150200100028 strip detector (RSD). C150200100029 HISTORY (20070111C) DR C150200100030 (20181104U) OS. Minor BIB corrections C150200100031 ENDBIB 29 0 C150200100032 COMMON 2 3 C150200100033 EN EN-ERR C150200100034 MEV MEV C150200100035 87.7 0.8 C150200100036 ENDCOMMON 3 0 C150200100037 ENDSUBENT 36 0 C150200199999 SUBENT C1502002 20070111 C079C150200200001 BIB 3 6 C150200200002 REACTION 1(2-HE-6(A,TOT),,EN) C150200200003 2(2-HE-6(A,TOT),,WID) C150200200004 ERR-ANALYS The uncertainties quoted for the resonance width C150200200005 are statistical only. Systematic uncertainties are C150200200006 expected to be 200 keV. C150200200007 STATUS (TABLE) Data taken from Table 1 C150200200008 ENDBIB 6 0 C150200200009 COMMON 1 3 C150200200010 ERR-SYS C150200200011 KEV C150200200012 200. C150200200013 ENDCOMMON 3 0 C150200200014 DATA 4 4 C150200200015 DATA 1DATA-ERR 1DATA 2DATA-ERR 2 C150200200016 MEV MEV KEV KEV C150200200017 9.60 0.01 141. 10. C150200200018 10.23 0.01 296. 15. C150200200019 11.00 0.02 200. 80. C150200200020 11.80 0.02 121. 10. C150200200021 ENDDATA 6 0 C150200200022 ENDSUBENT 21 0 C150200299999 ENDENTRY 2 0 C150299999999