ENTRY C1711 20090825 C093C171100000001 SUBENT C1711001 20090825 C093C171100100001 BIB 9 29 C171100100002 TITLE First observation of excited states in 172Hg C171100100003 AUTHOR (M.Sandzelius,E.Ganioglu,B.Cederwall,B.Hadinia, C171100100004 K.Andgren,T.Back,T.Grahn,P.Greenlees,U.Jakobsson, C171100100005 A.Johnson,P.M.Jones,R.Julin,S.Juutin En,S.Ketelhut, C171100100006 A.Khaplanov,M.Leino,M.Nyman, P.Peura,P.Rahkila, C171100100007 J.Saren,C.Scholey,J.Uusitalo,R.Wyss) C171100100008 INSTITUTE (2SWDKTH,2SF JYV,2TUKSTU) C171100100009 REFERENCE (J,PR/C,79,064315,2009) C171100100010 FACILITY (CYCLO,2SF JYV) Experiment was performed at the C171100100011 Accelerator Laboratory of the University of C171100100012 Jyvaskyla, employing the K130 cyclotron C171100100013 SAMPLE Self-supporting metallic foil enriched in 96Ru to C171100100014 96.5% with thickness of a 500 mu-g/cm2 . C171100100015 DETECTOR (HPGE)Prompt gamma rays were detected at the target C171100100016 position by the JUROGAM array consisting of 43 C171100100017 EUROGAM phase I and GASP type Compton-suppressed C171100100018 germanium detectors. C171100100019 (MAGSP)Gas-filled recoil magnetic separator was used C171100100020 with subsequent implantation of selected ions in a C171100100021 double-sided silicon strip detectors C171100100022 (SISD)Double-sided silicon strip detector (DSS)has an C171100100023 effective area of 60x40 mm2, with 200 individual C171100100024 strips at a pitch of 1 mm in both directions, C171100100025 leading to 4800 independent pixels in total. C171100100026 METHOD Recoil-decay tagging method was used to get C171100100027 clean prompt gamma ray spectra. Aplha decay of C171100100028 implanted nuclei was used to identify the nucleus C171100100029 172Hg. C171100100030 HISTORY (20090825C) Compiled by S.H. C171100100031 ENDBIB 29 0 C171100100032 NOCOMMON 0 0 C171100100033 ENDSUBENT 32 0 C171100199999 SUBENT C1711002 20090825 C093C171100200001 BIB 4 9 C171100200002 REACTION (44-RU-96(36-KR-78,2N)80-HG-172,PAR,SIG) C171100200003 Cross section was determined for excited states of C171100200004 172Hg, decaying by gamma rays C171100200005 STATUS (TABLE) Data taken from text p. 2 of the reference C171100200006 EN-SEC (E-LVL,80-HG-172) C171100200007 ERR-ANALYS (ERR-T) total uncertainty C171100200008 (ERR-1)Systematic uncertainty in target homogeneity C171100200009 (ERR-2) Systematic uncertainty in alpha branching ratioC171100200010 (ERR-3)Systematic uncertainty in DSS efficiency C171100200011 ENDBIB 9 0 C171100200012 COMMON 3 3 C171100200013 ERR-1 ERR-2 ERR-3 C171100200014 PER-CENT PER-CENT PER-CENT C171100200015 25.0 10.0 1.0 C171100200016 ENDCOMMON 3 0 C171100200017 DATA 6 1 C171100200018 EN E-LVL E-LVL E-LVL DATA ERR-T C171100200019 MEV KEV KEV KEV NB NB C171100200020 345.0 673.0 1519.0 2279.0 15.0 7.0 C171100200021 ENDDATA 3 0 C171100200022 ENDSUBENT 21 0 C171100299999 ENDENTRY 2 0 C171199999999