ENTRY C1957 20121115 C124C195700000001 SUBENT C1957001 20121115 C124C195700100001 BIB 10 37 C195700100002 TITLE Gamma-ray spectroscopy of one-proton knockout from 45ClC195700100003 AUTHOR (L.A.Riley,P.Adrich,N.Ahsan,T.R.Baugher,D.Bazin, C195700100004 B.A.Brown,J.M.Cook,P.D.Cottle,C.Aa.Diget,A.Gade, C195700100005 T.Glasmacher,K.E.Hosier,K.W.Kemper,A.Ratkiewicz, C195700100006 K.P.Siwek,J.A.Tostevin,A.Volya,D.Weisshaar) C195700100007 INSTITUTE (1USAMSU,1USAFSU,2UK SUR) C195700100008 (1USAUSA) Ursinus College, Collegeville, Pennsylvania C195700100009 REFERENCE (J,PR/C,86,047301,2012) C195700100010 FACILITY (CYCTM,1USAMSU) The experiment was performed at the C195700100011 Coupled-Cyclotron Facility of the National C195700100012 Superconducting Cyclotron Laboratory at Michigan C195700100013 State University C195700100014 SAMPLE 9Be reaction target with thickness of 376 mg/cm2 C195700100015 mounted at the target position of the S800 magnetic C195700100016 spectrograph C195700100017 DETECTOR (MAGSP) Outgoing 44S particles were momentum analyzed C195700100018 in S800 spectrograph and identified by detectors in C195700100019 S800 focal plane C195700100020 (SCIN,IOCH) Outgoing particles were identified by C195700100021 time of flight using scintillation detectors in focal C195700100022 plane and by energy loss in the S800 ionization chamberC195700100023 (HPGE) Gamma rays emitted by excited reaction C195700100024 products were detected with the Segmented Germanium C195700100025 Array (SeGA) of 32-fold segmented high-purity C195700100026 germanium detectors in coincidence with 44S particles C195700100027 detected in the focal plane of the S800 spectrometer C195700100028 METHOD (EDE,COINC,TOF) C195700100029 INC-SOURCE (KINDT) A cocktail beam including 16% 45Cl was C195700100030 produced by fragmentation of a 140 MeV/nucleon 48Ca C195700100031 primary beam incident on a 705 mg/cm2 9Be C195700100032 fragmentation target. Components of the secondary C195700100033 beam were separated in the A1900 fragment separator. C195700100034 Incoming 45Cl particles were identified using time of C195700100035 flight measured between scintillators mounted at the C195700100036 extended focal plane of the A1900 and at the object C195700100037 position of the S800 analysis line C195700100038 HISTORY (20121115C) Compiled by S.H. C195700100039 ENDBIB 37 0 C195700100040 COMMON 1 3 C195700100041 EN C195700100042 MEV/A C195700100043 99.6 C195700100044 ENDCOMMON 3 0 C195700100045 ENDSUBENT 44 0 C195700199999 SUBENT C1957002 20121115 C124C195700200001 BIB 3 9 C195700200002 REACTION (4-BE-9(17-CL-45,X)16-S-44,,SIG) C195700200003 STATUS (TABLE) Data taken from text on p. 1 of the reference C195700200004 ERR-ANALYS (ERR-T) Total uncertainty C195700200005 (ERR-1) Systematic uncertainty in incident beam C195700200006 composition C195700200007 (ERR-2) Systematic uncertainty in the correction for C195700200008 the momentum acceptance of S800 spectrometer C195700200009 (ERR-3) Systematic uncertainty in software gates used C195700200010 for selection of reaction of interest C195700200011 ENDBIB 9 0 C195700200012 COMMON 3 3 C195700200013 ERR-1 ERR-2 ERR-3 C195700200014 PER-CENT PER-CENT PER-CENT C195700200015 8.0 3.0 1.0 C195700200016 ENDCOMMON 3 0 C195700200017 DATA 2 1 C195700200018 DATA ERR-T C195700200019 MB MB C195700200020 13.0 1.0 C195700200021 ENDDATA 3 0 C195700200022 ENDSUBENT 21 0 C195700299999 SUBENT C1957003 20121115 C124C195700300001 BIB 4 4 C195700300002 REACTION (4-BE-9(17-CL-45,X)16-S-44,PAR,SIG) C195700300003 STATUS (TABLE) Data taken from tab. 1 of the reference C195700300004 ERR-ANALYS (ERR-T) Total uncertainty C195700300005 EN-SEC (E-LVL,16-S-44) C195700300006 ENDBIB 4 0 C195700300007 NOCOMMON 0 0 C195700300008 DATA 4 6 C195700300009 E-LVL DATA ERR-T DATA-MAX C195700300010 KEV MB MB MB C195700300011 0.0 1.3 C195700300012 1320.0 2.4 0.5 C195700300013 2150.0 2.2 0.2 C195700300014 2270.0 3.5 0.3 C195700300015 2464.0 3.6 0.3 C195700300016 3301.0 0.9 0.2 C195700300017 ENDDATA 8 0 C195700300018 ENDSUBENT 17 0 C195700399999 ENDENTRY 3 0 C195799999999