ENTRY C2033 20130702 C133C203300000001 SUBENT C2033001 20130702 C133C203300100001 BIB 10 39 C203300100002 TITLE Measurement of radiative proton capture on 18F and C203300100003 implications for oxygen-neon novae C203300100004 AUTHOR (C.Akers,A.M.Laird,B.R.Fulton,C.Ruiz,D.W.Bardayan, C203300100005 L.Buchmann,G.Christian,B.Davids,L.Erikson,J.Fallis, C203300100006 U.Hager,D.Hutcheon,L.Martin,A.St.J.Murphy,K.Nelson, C203300100007 A.Spyrou,C.Stanford,D.Ottewell,A.Rojas) C203300100008 INSTITUTE (1CANTMF,1USAORL,1USABNW,1USACSM,2UK EDG,1CANMCM, C203300100009 1USAMSU) C203300100010 (2UK UK) University of York, York C203300100011 (1CANCAN) Univ.of Waterloo, Waterloo, Ontario C203300100012 REFERENCE (J,PRL,110,262502,2013) C203300100013 FACILITY (LINAC,1CANTMF) Experiment performed using DRAGOON C203300100014 recoil separator of the ISAC radioactive beam facility C203300100015 located at the TRIUMF C203300100016 SAMPLE Differentially pumped windowless gas target C203300100017 containing hydrogen at the pressure of 7.5 torr. C203300100018 DETECTOR (BGO) Gas target chamber was surrounded by a high C203300100019 efficiency Bismuth Germanate (BGO) array to detect C203300100020 prompt gamma rays C203300100021 (MAGSP) High suppression two-stage electromagnetic C203300100022 separator to momentum analyze the recoiling beam C203300100023 (MCPLT,IOCH) The heavy ion detection system, located C203300100024 downstream of the final focus of the separator, C203300100025 consists of two microchannel plate detectors used for C203300100026 measuring recoil time of flight, and a multianode C203300100027 ionization chamber, used for measuring recoil energy C203300100028 loss. C203300100029 INC-SOURCE The 18F beam was produced using a 500 MeV C203300100030 proton beam incident on a silicon carbide target. C203300100031 Mass 18 products were extracted, ionized in a FEBIAD C203300100032 ion source and filtered using a high resolution mass C203300100033 separator.An average 18F(4+) beam intensity of C203300100034 1.74E+6 ions/sec was delivered to the experiment. C203300100035 ERR-ANALYS (ERR-1) Systematic uncertainty in beam normalization C203300100036 (ERR-2) Syst. uncertainty in charge state distribution C203300100037 (ERR-3) Syst. uncertainty in target stopping power C203300100038 (ERR-4) Syst. uncertainty in MCP efficiency C203300100039 (ERR-T) Total uncertainty C203300100040 HISTORY (20130702C) Compiled by S.H. C203300100041 ENDBIB 39 0 C203300100042 COMMON 5 3 C203300100043 EN-RES-CM ERR-1 ERR-2 ERR-3 ERR-4 C203300100044 KEV PER-CENT PER-CENT PER-CENT PER-CENT C203300100045 665.0 18.0 4.6 5.4 0.79 C203300100046 ENDCOMMON 3 0 C203300100047 ENDSUBENT 46 0 C203300199999 SUBENT C2033002 20130702 C133C203300200001 BIB 2 3 C203300200002 REACTION 1(1-H-1(9-F-18,G),,WID/STR) C203300200003 2(1-H-1(9-F-18,G),,WID) C203300200004 STATUS (TABLE) Data taken from text p. 3 of the reference C203300200005 ENDBIB 3 0 C203300200006 NOCOMMON 0 0 C203300200007 DATA 6 1 C203300200008 DATA 1-ERR-T 1+ERR-T 1DATA 2-ERR-T 2+ERR-T 2C203300200009 MILLI-EV MILLI-EV MILLI-EV MILLI-EV MILLI-EV MILLI-EV C203300200010 19.0 16.0 45.0 72.0 61.0 172.0 C203300200011 ENDDATA 3 0 C203300200012 ENDSUBENT 11 0 C203300299999 ENDENTRY 2 0 C203399999999