ENTRY C2183 20150921 C154C218300000001 SUBENT C2183001 20150921 C154C218300100001 BIB 7 22 C218300100002 TITLE Proton capture cross section of 72Ge and C218300100003 astrophysical implications C218300100004 AUTHOR (F.Naqvi,S.J.Quinn,A.Spyrou,A.Battaglia,M.Couder, C218300100005 P.A.DeYoung,A.C.Dombos,X.Fang,J.Gorres,A.Kontos,Q.Li, C218300100006 S.Lyons,D.Robertson,A.Simon,K.Smith,M.K.Smith,E.Stech, C218300100007 W.P.Tan,M.Wiescher) C218300100008 INSTITUTE (1USAMSU,1USANOT,1USAHPE) C218300100009 REFERENCE (J,PR/C,92,025804,2015) C218300100010 FACILITY (VDGT,1USANOT)The experiment was performed at the C218300100011 Nuclear Structure Laboratory at the University of C218300100012 Notre Dame using a 11 MV FN Tandem Van de Graff C218300100013 accelerator C218300100014 DETECTOR (NAICR) The gamma rays following the interaction in C218300100015 the target were detected with a gamma-summing C218300100016 detector SuN, developed at the National C218300100017 Superconducting Cyclotron Laboratory, Michigan State C218300100018 University. SuN is a NaI(Tl) cylinder, 16 in. in C218300100019 diameter and 16 in. in length divided into eight C218300100020 optically isolated segments. The volume of the C218300100021 detector allows for total absorption of all the gamma C218300100022 rays emitted during the reaction C218300100023 HISTORY (20150921C) Compiled by S.H. C218300100024 ENDBIB 22 0 C218300100025 NOCOMMON 0 0 C218300100026 ENDSUBENT 25 0 C218300199999 SUBENT C2183002 20150921 C154C218300200001 BIB 5 13 C218300200002 REACTION (32-GE-72(P,G)33-AS-73,,SIG) C218300200003 STATUS (TABLE) Data taken from tab. 2 of the reference C218300200004 SAMPLE Natural Ge target with thickness of 1.79 mg/cm2 C218300200005 ERR-ANALYS (ERR-T) Total uncertainty C218300200006 (ERR-S) Statistical uncertainty in the number of countsC218300200007 in the sum peak C218300200008 (ERR-1,10.0,15.0) Systematic uncertainty due to sum C218300200009 peak efficiency C218300200010 (ERR-2,5.0,14.0) Systematic uncertainty in beam currentC218300200011 measurement C218300200012 (ERR-3) Systematic uncertainty in target thickness C218300200013 ANALYSIS The cross section of producing the 5.7 mu-s isomer C218300200014 at 427.9 keV in 73As is not included C218300200015 ENDBIB 13 0 C218300200016 COMMON 2 3 C218300200017 ERR-S ERR-3 C218300200018 PER-CENT PER-CENT C218300200019 3.0 5.0 C218300200020 ENDCOMMON 3 0 C218300200021 DATA 4 10 C218300200022 EN-CM EN-RSL DATA ERR-T C218300200023 MEV MEV MB MB C218300200024 1.82 0.08 0.17 0.03 C218300200025 2.02 0.07 0.38 0.05 C218300200026 2.23 0.07 0.69 0.10 C218300200027 2.43 0.07 1.08 0.12 C218300200028 2.63 0.06 1.84 0.19 C218300200029 2.83 0.06 2.31 0.31 C218300200030 3.03 0.06 2.90 0.34 C218300200031 3.23 0.06 4.58 0.82 C218300200032 3.43 0.05 6.61 1.16 C218300200033 3.63 0.05 8.55 1.37 C218300200034 ENDDATA 12 0 C218300200035 ENDSUBENT 34 0 C218300299999 ENDENTRY 2 0 C218399999999