ENTRY C2238 20160921 C165C223800000001 SUBENT C2238001 20160921 C165C223800100001 BIB 9 28 C223800100002 TITLE Measurement of the Ec.m.r. = 259 keV resonance in the C223800100003 14N(p,gamma)15-O reaction C223800100004 AUTHOR (S.Daigle,K.J.Kelly,A.E.Champagne,M.Q.Buckner, C223800100005 C.Iliadis,C.Howard) C223800100006 INSTITUTE (1USANCA,1USATNL) C223800100007 REFERENCE (J,PR/C,94,025803,2016) C223800100008 FACILITY (VDG,1USATNL) Experiment performed using 1 MV JN Van C223800100009 de Graaff accelerator at the Laboratory for C223800100010 Experimental Nuclear Astrophysics located at the C223800100011 Triangle Universities Nuclear Laboratory. C223800100012 SAMPLE Nitrogen targets were prepared by implanting 14N ions C223800100013 into (0.35+-0.05)-mm-thick tantalum backings of 99.95% C223800100014 metals-basis purity. The target stoichiometry was C223800100015 determined via Rutherford backscattering spectrometry. C223800100016 DETECTOR (HPGE) Coaxial HPGe detector with a diameter of (89.0 C223800100017 +-0.5) mm and a length of (91.6+-1.0) mm, resulting in C223800100018 135% relative efficiency. The HPGe and target chamber C223800100019 were surrounded by an annulus of NaI(Tl) C223800100020 scintillators, which were not used in present C223800100021 measurements. C223800100022 (NAICR) Segmented annular detector consisting of 24 C223800100023 position sensitive trapezoidal crystals with C223800100024 dimensions 55.0 x 6.0 x 5.5/7.0 cm3 (L x H x W). C223800100025 Each NaI(Tl) bar has a photomultiplier tube (PMT) C223800100026 coupled to either end. Position and energy of each C223800100027 detected photon could be reconstructed. C223800100028 METHOD (GSPEC) C223800100029 HISTORY (20160921C) Compiled by S.H. C223800100030 ENDBIB 28 0 C223800100031 NOCOMMON 0 0 C223800100032 ENDSUBENT 31 0 C223800199999 SUBENT C2238002 20160921 C165C223800200001 BIB 7 15 C223800200002 REACTION (7-N-14(P,G),PAR,WID/STR) C223800200003 STATUS (TABLE) Data taken from tab.4 of the reference C223800200004 FLAG (1.) Data measured with HPGe detector C223800200005 (2.) Data measured with APEX NaI(Tl) array C223800200006 EN-SEC (E-LVL,8-O-15) C223800200007 CORRECTION Summing corrections were made. C223800200008 ANALYSIS Yield was determined from combined yields for the threeC223800200009 dominant transitions 5181 keV, 6172 keV and 6792 keV. C223800200010 ERR-ANALYS (ERR-S) Statistical uncertainty C223800200011 (ERR-SYS) Systematic uncertainty C223800200012 (ERR-T) Total uncertainty C223800200013 (ERR-1) Systematic uncert. of beam current integration C223800200014 (ERR-2) Systematic uncertainty in resonance energy C223800200015 (ERR-3) Systematic uncertainty in total branching ratioC223800200016 (ERR-4) Systematic uncertainty in detection efficiency C223800200017 ENDBIB 15 0 C223800200018 COMMON 7 6 C223800200019 EN-RES-CM E-LVL E-LVL-ERR ERR-1 ERR-2 ERR-3 C223800200020 ERR-4 C223800200021 KEV KEV KEV PER-CENT PER-CENT PER-CENT C223800200022 PER-CENT C223800200023 259.0 7556.2 0.5 2.5 0.077 0.1 C223800200024 3.6 C223800200025 ENDCOMMON 6 0 C223800200026 DATA 5 3 C223800200027 DATA ERR-S ERR-SYS ERR-T FLAG C223800200028 MILLI-EV MILLI-EV MILLI-EV MILLI-EV NO-DIM C223800200029 12.42 0.29 0.55 1. C223800200030 12.76 0.20 0.57 2. C223800200031 12.60 0.3 C223800200032 ENDDATA 5 0 C223800200033 ENDSUBENT 32 0 C223800299999 ENDENTRY 2 0 C223899999999