ENTRY D0211 20041004 0000D021100000001 SUBENT D0211001 20041004 0000D021100100001 BIB 12 39 D021100100002 TITLE Charge-exchange reaction induced by 6He and D021100100003 nuclear densities D021100100004 AUTHOR (M.D.Cortina-Gil,A.Pakou,N.Alamanos,W.Mittig, D021100100005 P.Roussel-Chomaz,F.Auger,J.Barrette,Y.Blumenfeld, D021100100006 J.M.Casandjian,M.Chartier,E.Dietrich,V.Fekou-Youmbi, D021100100007 B.Fernandez,N.Frascaria,A.Gillibert,H.Laurent, D021100100008 A.Lepine-Szily,N.Orr,V.Pascalon,J.A.Scarpaci,J.L.Sida, D021100100009 T.Suomijarvi) D021100100010 INSTITUTE (2FR GAN,2FR SAC,1CANMCG,1USALRL,3BZLUSP,2FR CSN, D021100100011 2FR CAE,2GRCIOA) D021100100012 REFERENCE (J,NP/A,641,263,1998) D021100100013 (J,PL/B,371,14,1996) Exper. details (SAMPLE,DETECTOR) D021100100014 FACILITY (CYCLO,2FR GAN) D021100100015 (PRJFS,2FR GAN) D021100100016 INC-SOURCE The secondary beam was produced by fragmentation of a D021100100017 75 MeV/nucleon 13C beam delivered by the GANIL D021100100018 accelerator on a 1155 mg/cm 2 carbon production target,D021100100019 located between the two superconducting solenoids of D021100100020 the SISSI device. The secondary beam was analyzed by D021100100021 the alpha spectrometer with a magnetic rigidity set at D021100100022 2.82 Tm which corresponds to an average energy of D021100100023 41.6 MeV/nucleon for the 6He ions. D021100100024 MONITOR (3-LI-6(N,P)2-HE-6,,SIG) Absolute cross sections were D021100100025 obtained by comparing Gamow-Teller transition data withD021100100026 reported data for the inverse 6Li(n,p)6He reaction. D021100100027 MONIT-REF (,D.Pocanic+,J,CJP,65,687,1987) D021100100028 (,J.Rapaport+,J,PR/C,41,1920,1990) D021100100029 SAMPLE The reaction target was a 100 mu-m thick polypropylene D021100100030 foil, (CH2)3. D021100100031 DETECTOR (PSSCN) All the scattered particles were unambiguously D021100100032 identified in the focal plane of the spectromerer D021100100033 with an ionisation chamber and a plastic scintillater. D021100100034 The momentum and scattering angle were measured D021100100035 with two position sensitive drift chambers placed 70 cmD021100100036 apart and located near the focal plane D021100100037 of the spectrometer. D021100100038 STATUS (TABLE) Tables received from Dr. V.Lapoux D021100100039 (APRVD) Entry was approved by Dr. V.Lapoux D021100100040 HISTORY (20041004C) SD D021100100041 ENDBIB 39 0 D021100100042 NOCOMMON 0 0 D021100100043 ENDSUBENT 42 0 D021100199999 SUBENT D0211002 20041004 0000D021100200001 BIB 3 4 D021100200002 REACTION (1-H-1(2-HE-6,N)3-LI-6,PAR,DA) D021100200003 EN-SEC (E-LVL,3-LI-6) D021100200004 ERR-ANALYS (ANG-ERR) Scale error D021100200005 (DATA-ERR) Experimental error D021100200006 ENDBIB 4 0 D021100200007 COMMON 4 3 D021100200008 EN E-LVL EN-RSL ANG-RSL D021100200009 MEV/A MEV PER-CENT ADEG D021100200010 41.6 0.0 0.1 0.3 D021100200011 ENDCOMMON 3 0 D021100200012 DATA 4 15 D021100200013 ANG-CM ANG-ERR DATA-CM DATA-ERR D021100200014 ADEG ADEG MB/SR MB/SR D021100200015 1.54 0.033 18.969 4.742 D021100200016 2.90 0.061 22.494 4.499 D021100200017 4.31 0.091 21.690 3.253 D021100200018 5.72 0.121 20.150 2.015 D021100200019 7.14 0.151 19.268 0.963 D021100200020 8.56 0.181 17.572 0.879 D021100200021 10.00 0.211 16.920 0.846 D021100200022 11.42 0.241 15.168 0.758 D021100200023 12.86 0.271 13.850 0.693 D021100200024 14.30 0.301 13.499 1.350 D021100200025 15.75 0.331 10.395 1.559 D021100200026 17.20 0.362 9.587 1.438 D021100200027 18.66 0.392 7.336 1.467 D021100200028 20.16 0.423 5.621 1.124 D021100200029 21.63 0.454 4.330 0.866 D021100200030 ENDDATA 17 0 D021100200031 ENDSUBENT 30 0 D021100299999 ENDENTRY 2 0 D021199999999