ENTRY D0351 20060627 D049D035100000001 SUBENT D0351001 20060627 D049D035100100001 BIB 8 26 D035100100002 TITLE Fusion of 16O + 46,50Ti Near and Below the Coulomb D035100100003 Barrier D035100100004 AUTHOR (R.Liguori Neto, J.C.Acquadro, P.R.S.Gomes, D035100100005 A.Szanto de Toledo, C.F.Tenreiro, E.Crema, D035100100006 N.Carlin Filho, M.M.Coimbra) D035100100007 INSTITUTE (3BZLUSP) D035100100008 REFERENCE (J,NP/A,512,333,1990) D035100100009 (R,IFUSP/P-750,,1988) the same results D035100100010 DETECTOR (HPGE) The gamma-rays were measured with a HPGe D035100100011 detector, with an energy resolution of 2keV for the D035100100012 1332 keV gamma-ray from a 60Co source and efficiency D035100100013 of 21.5%. Th detector was placed at 55 degr. with D035100100014 respect to the beam direction, at a distance of 10 cm D035100100015 from the target. D035100100016 METHOD (GSPEC) For each bombarding energy of the studied D035100100017 systems, measurements were made in-beam and off-beam. D035100100018 ERR-ANALYS (DATA-ERR) Taking into account the experimental D035100100019 uncertainties involved in this experiment; e.g. D035100100020 statistical errors, systematic errors due to target D035100100021 thickness, absolute efficiency, yield calculation for D035100100022 Coulomb excitation and contaminant corrections, D035100100023 the total uncertainty in absolute cross section have D035100100024 been estimated to be between 8% and 20%. D035100100025 (EN-ERR-DIG) Digitizing error D035100100026 (ERR-DIG) Digitizing error D035100100027 HISTORY (20060627C) SD D035100100028 ENDBIB 26 0 D035100100029 COMMON 2 3 D035100100030 EN-ERR-DIG ERR-DIG D035100100031 MEV PER-CENT D035100100032 0.05 0.3 D035100100033 ENDCOMMON 3 0 D035100100034 ENDSUBENT 33 0 D035100199999 SUBENT D0351002 20060627 D049D035100200001 BIB 3 7 D035100200002 REACTION (22-TI-46(8-O-16,N+2P)28-NI-59,,SIG) D035100200003 SAMPLE The targets consisted of thin layer metallic D035100200004 Ti (isotopically enriched to 81.2% ) evaporated on D035100200005 0.1mm thick Ta backing. The effective target thickness,D035100200006 measured by the Rutherford backscattering method, D035100200007 was 97 mu-g/cm2, with an uncertainty of about 5%. D035100200008 STATUS (CURVE) Data from fig. 1 D035100200009 ENDBIB 7 0 D035100200010 NOCOMMON 0 0 D035100200011 DATA 3 6 D035100200012 EN-CM DATA DATA-ERR D035100200013 MEV MB MB D035100200014 21.902 0.42828 0.16290 D035100200015 24.458 10.129 1.0429 D035100200016 27.121 89.033 8.3564 D035100200017 31.014 202.17 18.835 D035100200018 34.659 258.29 24.123 D035100200019 42.044 221.89 25.469 D035100200020 ENDDATA 8 0 D035100200021 ENDSUBENT 20 0 D035100299999 SUBENT D0351003 20060627 D049D035100300001 BIB 3 7 D035100300002 REACTION (22-TI-46(8-O-16,2P+A)26-FE-56,,SIG) D035100300003 SAMPLE The targets consisted of thin layer metallic D035100300004 Ti (isotopically enriched to 81.2% ) evaporated on D035100300005 0.1mm thick Ta backing. The effective target thickness,D035100300006 measured by the Rutherford backscattering method, D035100300007 was 97 mu-g/cm2, with an uncertainty of about 5%. D035100300008 STATUS (CURVE) Data from fig. 1 D035100300009 ENDBIB 7 0 D035100300010 NOCOMMON 0 0 D035100300011 DATA 3 5 D035100300012 EN-CM DATA DATA-ERR D035100300013 MEV MB MB D035100300014 24.573 1.5775 0.23793 D035100300015 27.356 8.8742 0.91574 D035100300016 31.165 41.763 4.7050 D035100300017 34.765 93.928 8.7506 D035100300018 42.056 153.31 12.764 D035100300019 ENDDATA 7 0 D035100300020 ENDSUBENT 19 0 D035100399999 SUBENT D0351004 20060627 D049D035100400001 BIB 4 8 D035100400002 REACTION (22-TI-46(8-O-16,2N+P)29-CU-59,,SIG) D035100400003 SAMPLE The targets consisted of thin layer metallic D035100400004 Ti (isotopically enriched to 81.2% ) evaporated on D035100400005 0.1mm thick Ta backing. The effective target thickness,D035100400006 measured by the Rutherford backscattering method, D035100400007 was 97 mu-g/cm2, with an uncertainty of about 5%. D035100400008 DECAY-DATA (29-CU-59,1.37MIN,DG,914.,,DG,1399.,,DG,1865.) D035100400009 STATUS (CURVE) Data from fig. 1 D035100400010 ENDBIB 8 0 D035100400011 NOCOMMON 0 0 D035100400012 DATA 3 5 D035100400013 EN-CM DATA DATA-ERR D035100400014 MEV MB MB D035100400015 24.631 0.61915 0.12094 D035100400016 27.453 4.7732 0.71789 D035100400017 31.316 21.738 2.4489 D035100400018 34.839 42.001 4.7412 D035100400019 42.156 53.381 4.4568 D035100400020 ENDDATA 7 0 D035100400021 ENDSUBENT 20 0 D035100499999 SUBENT D0351005 20060627 D049D035100500001 BIB 3 7 D035100500002 REACTION (22-TI-50(8-O-16,2N+P)29-CU-63,,SIG) D035100500003 SAMPLE The targets consisted of thin layer metallic D035100500004 Ti (isotopically enriched to 76.4% ) evaporated on D035100500005 0.1mm thick Ta backing. The effective target thickness,D035100500006 measured by the Rutherford backscattering method, D035100500007 was 383 mu-g/cm2, with an uncertainty of about 5%. D035100500008 STATUS (CURVE) Data from fig. 1 D035100500009 ENDBIB 7 0 D035100500010 NOCOMMON 0 0 D035100500011 DATA 3 8 D035100500012 EN-CM DATA DATA-ERR D035100500013 MEV MB MB D035100500014 21.799 0.31303 0.84705E-01 D035100500015 23.797 3.5189 0.44655 D035100500016 25.513 27.054 3.1113 D035100500017 29.327 153.47 15.867 D035100500018 33.033 251.63 26.015 D035100500019 36.874 307.26 25.703 D035100500020 42.502 360.07 37.226 D035100500021 48.361 275.61 28.494 D035100500022 ENDDATA 10 0 D035100500023 ENDSUBENT 22 0 D035100599999 SUBENT D0351006 20060627 D049D035100600001 BIB 4 8 D035100600002 REACTION (22-TI-50(8-O-16,3N)30-ZN-63,,SIG) D035100600003 DECAY-DATA (30-ZN-63,38.1MIN,DG,669.) D035100600004 SAMPLE The targets consisted of thin layer metallic D035100600005 Ti (isotopically enriched to 76.4% ) evaporated on D035100600006 0.1mm thick Ta backing. The effective target thickness,D035100600007 measured by the Rutherford backscattering method, D035100600008 was 383 mu-g/cm2, with an uncertainty of about 5%. D035100600009 STATUS (CURVE) Data from fig. 1 D035100600010 ENDBIB 8 0 D035100600011 NOCOMMON 0 0 D035100600012 DATA 3 8 D035100600013 EN-CM DATA DATA-ERR D035100600014 MEV MB MB D035100600015 21.885 0.16277 0.79999E-01 D035100600016 23.817 1.7145 0.46395 D035100600017 25.593 13.468 2.0474 D035100600018 29.425 56.315 9.9887 D035100600019 33.114 125.27 15.370 D035100600020 36.913 172.47 21.120 D035100600021 42.530 121.13 13.700 D035100600022 48.348 43.738 9.6967 D035100600023 ENDDATA 10 0 D035100600024 ENDSUBENT 23 0 D035100699999 SUBENT D0351007 20060627 D049D035100700001 BIB 4 8 D035100700002 REACTION (22-TI-50(8-O-16,N+P)29-CU-64,,SIG) D035100700003 DECAY-DATA (29-CU-64,12.70HR,DG,203.,,DG,278.) D035100700004 SAMPLE The targets consisted of thin layer metallic D035100700005 Ti (isotopically enriched to 76.4% ) evaporated on D035100700006 0.1mm thick Ta backing. The effective target thickness,D035100700007 measured by the Rutherford backscattering method, D035100700008 was 383 mu-g/cm2, with an uncertainty of about 5%. D035100700009 STATUS (CURVE) Data from fig. 1 D035100700010 ENDBIB 8 0 D035100700011 NOCOMMON 0 0 D035100700012 DATA 3 6 D035100700013 EN-CM DATA DATA-ERR D035100700014 MEV MB MB D035100700015 23.841 1.3344 0.20134 D035100700016 25.664 9.6055 1.1763 D035100700017 29.580 31.938 3.6120 D035100700018 33.164 32.094 3.0031 D035100700019 37.102 21.991 2.7034 D035100700020 42.642 8.6744 1.0622 D035100700021 ENDDATA 8 0 D035100700022 ENDSUBENT 21 0 D035100799999 SUBENT D0351008 20060627 D049D035100800001 BIB 3 7 D035100800002 REACTION (22-TI-46(8-O-16,FUS),,SIG) D035100800003 SAMPLE The targets consisted of thin layer metallic D035100800004 Ti (isotopically enriched to 81.2% ) evaporated on D035100800005 0.1mm thick Ta backing. The effective target thickness,D035100800006 measured by the Rutherford backscattering method, D035100800007 was 97 mu-g/cm2, with an uncertainty of about 5%. D035100800008 STATUS (CURVE) Data from fig. 3 D035100800009 ENDBIB 7 0 D035100800010 NOCOMMON 0 0 D035100800011 DATA 3 6 D035100800012 EN-CM DATA DATA-ERR D035100800013 MEV MB MB D035100800014 22.124 0.42851 0.16508 D035100800015 24.926 21.870 D035100800016 27.937 177.87 D035100800017 31.647 486.77 D035100800018 35.378 717.22 D035100800019 42.794 1001.1 D035100800020 ENDDATA 8 0 D035100800021 ENDSUBENT 20 0 D035100899999 SUBENT D0351009 20060627 D049D035100900001 BIB 3 7 D035100900002 REACTION (22-TI-50(8-O-16,FUS),,SIG) D035100900003 SAMPLE The targets consisted of thin layer metallic D035100900004 Ti (isotopically enriched to 76.4% ) evaporated on D035100900005 0.1mm thick Ta backing. The effective target thickness,D035100900006 measured by the Rutherford backscattering method, D035100900007 was 383 mu-g/cm2, with an uncertainty of about 5%. D035100900008 STATUS (CURVE) Data from fig. 3 D035100900009 ENDBIB 7 0 D035100900010 NOCOMMON 0 0 D035100900011 DATA 3 8 D035100900012 EN-CM DATA DATA-ERR D035100900013 MEV MB MB D035100900014 21.939 0.64747 0.23152 D035100900015 23.968 9.9320 2.1463 D035100900016 25.951 78.492 D035100900017 29.768 368.97 D035100900018 33.642 640.90 D035100900019 37.439 854.11 D035100900020 43.186 1150.4 D035100900021 48.931 1242.0 D035100900022 ENDDATA 10 0 D035100900023 ENDSUBENT 22 0 D035100999999 ENDENTRY 9 0 D035199999999