ENTRY D0461 20080326 D060D046100000001 SUBENT D0461001 20080326 D060D046100100001 BIB 12 44 D046100100002 TITLE Measurement of Angular Distribution for the D046100100003 8Li(p,d)7Li Reaction D046100100004 AUTHOR (Li Yun-Ju,Li Zhi-Hong,Guo Bing,Wang You-Bao, D046100100005 Bai Xi-Xiang,Su Jun,Lian Gang,Zeng Sheng, D046100100006 Wang Bao-Xiang,Qin Xing,Jiang Chao,Liu Wei-Ping, D046100100007 Zhao Wei-Juan) D046100100008 INSTITUTE (3CPRAEP,3CPRZHN) D046100100009 (3CPRCPR) Institute of Modern Physics, Shanxi Normal D046100100010 University, Linfen 041004 D046100100011 REFERENCE (J,CPL,25,455,2008) D046100100012 FACILITY (VDGT,3CPRAEP) The radioactive nuclear beam facility D046100100013 of the HI-13 tandem accelerator, China Institute of D046100100014 Atomic Energy, Beijing 102413 D046100100015 INC-SOURCE A 44-MeV 7Li primary beam from the tandem D046100100016 accelerator impinged on a 4.8-cm- long deuterium gas D046100100017 cell at the pressure of 1.55 atm, and the 8Li D046100100018 secondary beam was produced via 2H(7Li,8Li)1H reaction.D046100100019 The energy of the 8Li secondary beam was 39.8 MeV, w D046100100020 ith the intensity of 3000 pps and purity of 78%~86%. D046100100021 SAMPLE A 1.93-mg/cm2-thick (CH2)n foil and a D046100100022 1.9-mg/cm2-thick carbon foil were used to measure D046100100023 the 8Li(p,d)7Li reaction in inverse kinematics and D046100100024 to evaluate the background, respectively. D046100100025 DETECTOR (TELES,SIBAR,SISD) A set of dE-E telescope D046100100026 consisting of a 63-mu-m-thick double sided silicon D046100100027 strip detector (DSSSD) and a 982-mu-m-thick quadrant D046100100028 silicon detector(MSQ). Both the detectors have 50mm D046100100029 x 50mm active area. The DSSSD is divided into 16 stripsD046100100030 with 3mm width on the front face by 0.1mm gaps and 16 D046100100031 similar orthogonal strips on the back face, making up D046100100032 256 pixels of 3mm x 3mm each, to provide quasi-pixel D046100100033 two dimensional position information. D046100100034 METHOD (EDE) D046100100035 ERR-ANALYS (ERR-T) The errors of differential cross section are D046100100036 mainly from the statistics, and the uncertainties of D046100100037 beam normalization and areal density of hydrogen D046100100038 atoms in the (CH2)n target (ERR-S,ERR-1,ERR-2). D046100100039 (ERR-S) Statistical errors D046100100040 (ERR-1) The uncertainties of beam normalization D046100100041 (ERR-2) The uncertainties of areal density of D046100100042 hydrogen atoms in the (CH2)n target D046100100043 STATUS (TABLE) Data were received from Dr. LI Yun-Ju D046100100044 (APRVD) Entry was approved by Dr. LI Yun-Ju D046100100045 HISTORY (20080326C) SD D046100100046 ENDBIB 44 0 D046100100047 COMMON 5 3 D046100100048 EN-CM EN-RSL-FW ERR-S ERR-1 ERR-2 D046100100049 MEV MEV PER-CENT PER-CENT PER-CENT D046100100050 4.0 0.54 5.0 4.0 2.0 D046100100051 ENDCOMMON 3 0 D046100100052 ENDSUBENT 51 0 D046100199999 SUBENT D0461002 20080326 D060D046100200001 BIB 2 3 D046100200002 REACTION (1-H-1(3-LI-8,D)3-LI-7,PAR,DA) D046100200003 EN-SEC (E-EXC-MIN,3-LI-7) D046100200004 (E-EXC-MAX,3-LI-7) D046100200005 ENDBIB 3 0 D046100200006 COMMON 2 3 D046100200007 E-EXC-MIN E-EXC-MAX D046100200008 MEV MEV D046100200009 0.0 0.477 D046100200010 ENDCOMMON 3 0 D046100200011 DATA 4 6 D046100200012 ANG-CM ANG-ERR DATA-CM ERR-T D046100200013 ADEG ADEG MB/SR MB/SR D046100200014 158.3 3.1 33.4 3.6 D046100200015 149.5 3.1 34.2 2.1 D046100200016 139.8 3.2 29.4 1.8 D046100200017 130.7 3.2 22.7 1.3 D046100200018 122.0 3.3 18.5 1.2 D046100200019 110.9 3.4 17.3 0.9 D046100200020 ENDDATA 8 0 D046100200021 ENDSUBENT 20 0 D046100299999 ENDENTRY 2 0 D046199999999